A comparison of empirical indoor relative humidity models with measured data

被引:17
|
作者
Cornick, S. M. [1 ]
Kumaran, M. K. [1 ]
机构
[1] Natl Res Council Canada, Inst Res Construct, Ottawa, ON K1A 0R6, Canada
关键词
indoor humidity; hygrothermal modeling; field monitoring and measurements; ventilation;
D O I
10.1177/1744259107081699
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The focus of this study is to examine the reliability of models that are available in the open literature for simulating the interior moisture conditions, comparing the predicted interior relative humidity (RH) to measured data. Four models, for predicting the indoor RH in houses are tested against measured RH data for 25 houses. The models considered are primarily developed as design tools. The models tested are the European Indoor Class Model, the BRE model, and the ASHRAE 160P simple and intermediate models. The RH in each house is measured in two different locations producing 50 data sets. The ASHRAE intermediate model seemed to be the most robust exhibiting lower errors when compared to measured data. The European Indoor Class also performed well and can be used when data regarding moisture generation and/or air change rates is not available. As a design tool, however, it is not universally conservative in estimating the indoor RH. The BRE is problematic and generally exhibits large positive errors for most of the houses surveyed. It is found to be not reliable for the North American houses investigated in the comparisons. The ASHRAE simple model also exhibited large positive errors and does not trend well with the measured conditions. Models that greatly overestimate the design loads should be used with caution as they may lead to complicated inefficient designs.
引用
收藏
页码:243 / 268
页数:26
相关论文
共 50 条
  • [41] Development and performance of a small relative humidity sensor for indoor microclimate measurements
    Cunningham, M.J.
    Building and Environment, 1998, 34 (03): : 349 - 352
  • [42] Efficiency of agricultural farms measured by data depth and DEA: comparison and empirical study
    Rada, Miroslav
    Sokol, Ondrej
    Cerny, Michal
    MATHEMATICAL METHODS IN ECONOMICS (MME 2018), 2018, : 451 - 456
  • [43] COMPARISON OF ION COMPOSITION DATA WITH EMPIRICAL-MODELS (COMMENT)
    KOHNLEIN, W
    ADVANCES IN SPACE RESEARCH, 1993, 13 (03) : 85 - &
  • [44] Modelling diurnal pattern of relative humidity from daily air temperature and relative humidity data of Hyderabad
    Srivastava, N. N.
    Rao, V. U. M.
    Saikia, U. S.
    Kumar, P. Vijaya
    Rao, A. V. M. Subba
    JOURNAL OF AGROMETEOROLOGY, 2011, 13 (01): : 25 - 30
  • [45] Comparison of Harmonic Models of Nonlinear Home Appliances Based on Measured Data
    Xie, Xiangmin
    Chen, Daolian
    2020 IEEE STUDENT CONFERENCE ON ELECTRIC MACHINES AND SYSTEMS (SCEMS 2020), 2020, : 1007 - 1011
  • [46] Performance comparison of two SDMA approaches for OFDM signals using measured indoor channel data
    Jia, YJ
    Tran, QT
    Hara, S
    IEICE TRANSACTIONS ON COMMUNICATIONS, 2006, E89B (04) : 1315 - 1324
  • [47] Influence of materials' moisture absorption properties on prediction of indoor relative humidity level
    Borodinecs, A.
    Zemitis, J.
    CONTRIBUTIONS TO BUILDING PHYSICS, 2013, : 883 - 887
  • [48] Temperature versus Relative Humidity: Which Is More Important for Indoor Mold Prevention?
    Wu, Haoxiang
    Wong, Jonathan Woon Chung
    JOURNAL OF FUNGI, 2022, 8 (07)
  • [49] Indoor relative humidity shapes influenza seasonality in temperate and subtropical climates in China
    Lei, Hao
    Yang, Mengya
    Dong, Zhaomin
    Hu, Kejia
    Chen, Tao
    Yang, Lei
    Zhang, Nan
    Duan, Xiaoli
    Yang, Shigui
    Wang, Dayan
    Shu, Yuelong
    Li, Yuguo
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2023, 126 : 54 - 63
  • [50] Sensitivity of airborne transmission of enveloped viruses to seasonal variation in indoor relative humidity
    Robey, Alison J.
    Fierce, Laura
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2022, 130