Precision of a new thermometer for rapid rectal temperature measurement in neonates

被引:4
|
作者
Dollberg, S [1 ]
Lahav, S [1 ]
Mimouni, FB [1 ]
机构
[1] Lis Matern Hosp, Tel Aviv Sourasky Med Ctr, Dept Neonatol, IL-64239 Tel Aviv, Israel
关键词
thermometry; newborn; accurate; reproducible;
D O I
10.1055/s-2001-13636
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
The objective of this article is to evaluate the accuracy and reproducibility of a Penguin electronic thermometer compared with a mercury-in-glass thermometer for rectal thermometry in newborns. The mercury-in-glass thermometer is considered the "gold-standard" for rectal thermometry. Unfortunately, accurate measurement with a mercury-in-glass thermometer requires at least 4 minutes, Rectal temperature was obtained in 224 term and near-term infants using a mercury-in-glass and a Penguin thermometers. Paired t-test was used to test the difference between the means, and F-test was used to test the difference between the variances of the two instruments. One hundred and sixty-one of the temperature measurements (72%) taken with the Penguin thermometer were within +/-0.2 degreesC and 208 (93%) within +/-0.5 degreesC from the measurements made with the mercury-in-glass thermometer. The differences in means and in variances were not significantly different between the instruments. The Penguin thermometer is an accurate and reproducible tool for measuring rectal temperature in term and near-term infants compared with the mercury-in-glass thermometer.
引用
收藏
页码:103 / 105
页数:3
相关论文
共 50 条
  • [31] THE USE OF AN ELECTRONIC THERMOMETER IN INTRAORAL TEMPERATURE-MEASUREMENT
    HARUN, Z
    STAFFORD, GD
    HUGGETT, R
    JOURNAL OF ORAL REHABILITATION, 1988, 15 (03) : 285 - 293
  • [32] Intravesical thermometer: an unusual complication of vaginal temperature measurement
    Riou, PJ
    Harris, A
    JOURNAL OF ACCIDENT & EMERGENCY MEDICINE, 1998, 15 (06): : 432 - 432
  • [33] MEASUREMENT OF AVERAGE FACE TEMPERATURE USING INFRARED THERMOMETER
    NISHI, Y
    SUZUKI, K
    OOHORI, T
    INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 1987, 31 (04) : 354 - 355
  • [34] ACCURACY OF TEMPERATURE MEASUREMENT BY A STANDARD PLATINUM RESISTANCE THERMOMETER
    SYCHEV, VV
    GORBUNOV.NI
    HIGH TEMPERATURE, 1965, 3 (04) : 579 - &
  • [35] MEASUREMENT OF COMMUTATOR TEMPERATURE BY A SLIDING-CONTACT THERMOMETER
    BATES, JJ
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1965, 112 (04): : 835 - &
  • [36] The influence of covariances on the uncertainty of temperature measurement by resistance thermometer
    Duris, S
    Palencár, R
    Measurement 2005, Proceedings, 2005, : 34 - 38
  • [37] Precise measurement of the temperature of a silicon wafer by an optical-interference contactless thermometer during rapid plasma processing
    Kameda, Asaki
    Mizukawa, Yuri
    Hanafusa, Hiroaki
    Higashi, Seiichiro
    JOURNAL OF APPLIED PHYSICS, 2020, 127 (20)
  • [38] Rapid rectal temperature recording of pigs
    Koch, R
    Eickhoff, K
    Grunert, K
    Wendt, M
    Bollwahn, W
    Giese, WW
    TIERARZTLICHE UMSCHAU, 1998, 53 (09): : 562 - 567
  • [39] NEW PLATINUM RESISTANCE THERMOMETER FOR PRECISION MEASUREMENTS OF HIGH TEMPERATURES
    ALIEVA, FZ
    MEASUREMENT TECHNIQUES-USSR, 1964, (06): : 487 - &
  • [40] High precision, fast ultrasonic thermometer based on measurement of the speed of sound in air
    Huang, KN
    Huang, CF
    Li, YC
    Young, MS
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (11): : 4022 - 4027