Abdominal Enhanced Computed Tomography Image by Artificial Intelligence Algorithm in the Diagnosis of Abdominal Aortic Aneurysm

被引:0
|
作者
Zheng, Tao [1 ]
Shao, Guofeng [1 ]
Zhou, Qingyun [1 ]
Wang, Qinning [1 ]
Ye, Mengmeng [1 ]
机构
[1] Ningbo Med Ctr Lihuili Hosp, Dept Cardiothorac & Vasc Surg, Ningbo 315000, Zhejiang, Peoples R China
关键词
EPIDEMIOLOGY; ANGIOGRAPHY; MANAGEMENT;
D O I
10.1155/2021/8721464
中图分类号
TP31 [计算机软件];
学科分类号
081202 ; 0835 ;
摘要
The purpose of this study was to investigate the clinical value of CT angiography (CTA) images processed by the segmentation denoising technique based on deep convolution neural network algorithm in the diagnosis of abdominal aortic aneurysm (AAA) and the detection of disease changes. A total of 98 patients with ruptured AAA were retrospectively selected as the study subjects. Patients were grouped according to whether the CTA images were optimized, the images receiving artificial intelligence segmentation and denoising were set as the observation group, and the CTA images without optimization were set as the control group. The detection and diagnosis effects of CTA images before and after the treatment were compared. The surgical results were used as the standard to analyze the diagnostic effect, and the maximum diameter measurement results of AAA and the proportion results of intraluminal thrombus (ILT) were compared. Although the sensitivity and accuracy of diagnosis in the observation group (97.73% and 94.9%) were higher than those in the control group (95.45% and 92.86%), there was no significant statistical significance (P>0.05). When the diameter of AAA was no less than 5 cm, all results showed that the coverage percentage of intraluminal thrombus (ILT) was over 50%. When the diameter of AAA was less than 5 cm, only 55.56% of the results showed that the percentage of ILT coverage was over 50%, with considerable differences (P>0.05). According to the results of the study, it was found that there was a certain relationship between the thrombus coverage of the abdominal aortic wall and the growth rate of AAA. The deep convolution neural network algorithm had a certain effect on the treatment of CTA, but it is not obvious. However, CTA had a better clinical diagnostic effect on AAA.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Artificial Intelligence Application to Screen Abdominal Aortic Aneurysm Using Computed tomography Angiography
    Spinella, Giovanni
    Fantazzini, Alice
    Finotello, Alice
    Vincenzi, Elena
    Boschetti, Gian Antonio
    Brutti, Francesca
    Magliocco, Marco
    Pane, Bianca
    Basso, Curzio
    Conti, Michele
    [J]. JOURNAL OF DIGITAL IMAGING, 2023, 36 (05) : 2125 - 2137
  • [2] Artificial Intelligence Application to Screen Abdominal Aortic Aneurysm Using Computed tomography Angiography
    Giovanni Spinella
    Alice Fantazzini
    Alice Finotello
    Elena Vincenzi
    Gian Antonio Boschetti
    Francesca Brutti
    Marco Magliocco
    Bianca Pane
    Curzio Basso
    Michele Conti
    [J]. Journal of Digital Imaging, 2023, 36 (5) : 2125 - 2137
  • [3] Artificial intelligence in abdominal aortic aneurysm
    Raffort, Juliette
    Adam, Cedric
    Carrier, Marion
    Ballaith, Ali
    Coscas, Raphael
    Jean-Baptiste, Elixene
    Hassen-Khodja, Reda
    Chakfe, Nabil
    Lareyre, Fabien
    [J]. JOURNAL OF VASCULAR SURGERY, 2020, 72 (01) : 321 - +
  • [4] Automatic Measurement of Maximal Diameter of Abdominal Aortic Aneurysm on Computed Tomography Angiography Using Artificial Intelligence
    Lareyre, Fabien
    Chaudhuri, Arindam
    Flory, Violaine
    Augene, Emmanuel
    Adam, Cedric
    Carrier, Marion
    Amrani, Samantha
    Chikande, Julien
    Cong Duy Le
    Raffort, Juliette
    [J]. ANNALS OF VASCULAR SURGERY, 2022, 83 : 202 - 211
  • [5] AORTIC DISSECTION WITH CONCURRENT ABDOMINAL AORTIC-ANEURYSM - COMPUTED-TOMOGRAPHY DIAGNOSIS
    TAYLOR, CR
    AUGUST, D
    GREENWOOD, L
    CAMBRIA, RP
    [J]. CT-JOURNAL OF COMPUTED TOMOGRAPHY, 1987, 11 (04): : 392 - 396
  • [6] Comparison with computed tomography of two ultrasound devices for diagnosis of abdominal aortic aneurysm
    Vidakovic, Radosav
    Feringa, Harm H. H.
    Kuiper, Ruud J.
    Karagiannis, Stefanos E.
    Schouten, Olaf
    Dunkelgrun, Martin
    Hoeks, Sanne E.
    Bom, Nicolaas
    Bax, Jeroen J.
    Neskovic, Aleksandar N.
    Poldermans, Don
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (12): : 1786 - 1791
  • [7] Computed tomography for ruptured abdominal aortic aneurysm? Reply
    Gervais, DA
    Whitman, GJ
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (19): : 1273 - 1273
  • [8] Measuring abdominal aortic diameters in routine abdominal computed tomography scans and implications for abdominal aortic aneurysm screening
    Claridge, Rachel
    Arnold, Sam
    Morrison, Neil
    van Rij, Andre M.
    [J]. JOURNAL OF VASCULAR SURGERY, 2017, 65 (06) : 1637 - 1642
  • [9] COMPUTED TOMOGRAPHIC DIAGNOSIS OF ABDOMINAL AORTIC-ANEURYSM
    HADAR, H
    ZELIKOVSKI, A
    REISS, R
    [J]. CT-JOURNAL OF COMPUTED TOMOGRAPHY, 1981, 5 (01): : 1 - 7
  • [10] Delayed enhancement on computed tomography in abdominal aortic aneurysm wall
    Sakuta, Akiko
    Kimura, Fumiko
    Aoka, Yoshikazu
    Aomi, Shigeyuki
    Hagiwara, Nobuhisa
    Kasanuki, Hiroshi
    [J]. HEART AND VESSELS, 2007, 22 (02) : 79 - 87