Analysis of human serum lipoprotein lipid composition using MALDI-TOF mass spectrometry

被引:0
|
作者
Hidaka, Hiroya
Hanyu, Noboru
Sugano, Mitsutoshi
Kawasaki, Kenji
Yamauchi, Kazuyoshi
Katsuyama, Tsutomu
机构
[1] Shinshu Univ, Sch Hlth Sci, Dept Biomed Lab Sci, Nagano 3908621, Japan
[2] Shinonoi Gen Hosp, Clin Labs, Shinonoi, Japan
[3] Shinshu Univ Hosp, Dept Lab Med, Matsumoto, Nagano, Japan
[4] Shinshu Univ, Sch Med, Dept Lab Med, Matsumoto, Nagano, Japan
来源
ANNALS OF CLINICAL AND LABORATORY SCIENCE | 2007年 / 37卷 / 03期
关键词
MALDI-TOF mass spectrometry; lipoproteins; lipids; phospholipids; lysophospholipids; HIGH-PERFORMANCE LIQUID; REVERSE CHOLESTEROL TRANSPORT; THIN-LAYER-CHROMATOGRAPHY; ASSISTED LASER-DESORPTION; PHOSPHOLIPID CLASSES; FATTY-ACID; SCAVENGER RECEPTOR; SEPARATION; PHOSPHATIDYLCHOLINE; DIACYLGLYCEROL;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
This study used matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) to identify all lipid classes in human serum lipoproteins. After the major lipoproteins classes were isolated from serum by ultracentrifugation, the lipids were extracted and mixed with 2,5-dihydroxybenzoic acid (2,5-DHB) dissolved in Folch's solution (chloroform/methanol 2: 1, v/v). MALDI-TOF MS analysis of the samples identified phospholipids (PLs), lysophospholipids (lysoPLs), sphingolipids (SLs), triglycerides (TGs), cholesteryl esters (CEs), and free cholesterol; it also showed the characteristics of individual fatty acid chains in serum lipids. MALDI-TOF MS allowed analysis of strongly hydrophobic and non-polar molecules such as CEs and TGs as well as hydrophilic molecules such as phospholipids. Direct analysis of fatty acids was not possible. The concentrations of lipids were not consistent with the ion peak intensities, since the extent of polarity affected the ionization characteristics of the molecules. However, lipid molecules with similar molecular structures but various fatty acid chains, such as phosphatidylcholine (PCs), were analyzed quantitatively by MALDI-TOF MS. Quantitative measurement of cholesterol was possible with the use of an internal standard. This study shows that MALDI-TOF MS can be used for direct investigation and quantitative analysis of the phospholipid composition of serum lipoproteins.
引用
收藏
页码:213 / 221
页数:9
相关论文
共 50 条
  • [21] Analysis of intact glucosinolates by MALDI-TOF mass spectrometry
    Botting, CH
    Davidson, NE
    Griffiths, DW
    Bennett, RN
    Botting, NP
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2002, 50 (05) : 983 - 988
  • [22] Applications of MALDI-TOF mass spectrometry in the analysis of Cryptosporidium
    Hall, K
    Claydon, MA
    Evason, DJ
    Smith, MS
    Watkins, J
    CRYPTOSPORIDIUM: THE ANALYTICAL CHALLENGE, 2001, (265): : 96 - 100
  • [23] MALDI-TOF mass spectrometry of bacteria
    Lay, JO
    MASS SPECTROMETRY REVIEWS, 2001, 20 (04) : 172 - 194
  • [24] Analysis of complex polymers by MALDI-TOF mass spectrometry
    Pasch, H
    Ghahary, R
    MACROMOLECULAR SYMPOSIA, 2000, 152 : 267 - 278
  • [25] MALDI-TOF Mass Spectrometry in Clinical Analysis and Research
    Li, Dandan
    Yi, Jia
    Han, Guobin
    Qiao, Liang
    ACS MEASUREMENT SCIENCE AU, 2022, 2 (05): : 385 - 404
  • [26] Analysis of glycated insulin by MALDI-TOF mass spectrometry
    Abul Farah, M
    Bose, S
    Lee, JH
    Jung, HC
    Kim, Y
    BIOCHIMICA ET BIOPHYSICA ACTA-GENERAL SUBJECTS, 2005, 1725 (03): : 269 - 282
  • [27] Analysis of viral glycoproteins by MALDI-TOF mass spectrometry
    Kim, YJ
    Freas, A
    Fenselau, C
    ANALYTICAL CHEMISTRY, 2001, 73 (07) : 1544 - 1548
  • [28] Lipid analysis of human HDL and LDL by MALDI-TOF mass spectrometry and 31P-NMR
    Schiller, J
    Zschörnig, O
    Petkovic, M
    Müller, M
    Arnhold, J
    Arnold, K
    JOURNAL OF LIPID RESEARCH, 2001, 42 (09) : 1501 - 1508
  • [29] Rapid Determination of Procyanidins Using MALDI-ToF/ToF Mass Spectrometry
    Rush, Michael D.
    Rue, Emily A.
    Wong, Alan
    Kowalski, Paul
    Glinsk, Jan A.
    van Breemen, Richard B.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2018, 66 (43) : 11355 - 11361
  • [30] Detection of sarin-butyrylcholinesterase adduct in human serum by MALDI-TOF mass spectrometry
    Cao, Y. (cao_ying2002@hotmail.com), 1600, Chinese Society for Mass Spectrometry (34):