Transcatheter closure of a residual postmyocardial infarction ventricular septal defect with the Amplatzer septal occluder

被引:43
|
作者
Lee, EM
Roberts, DH
Walsh, KP
机构
[1] Blackpool Victoria Hosp, Blackpool FY3 8NR, Lancs, England
[2] Alder Hey Childrens Hosp, Liverpool L2 2AP, Merseyside, England
关键词
ventricular septal defect; transcatheter closure; Amplatzer septal occluder;
D O I
10.1136/hrt.80.5.522
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Acute ventricular septal rupture following myocardial infarction carries a high mortality. Early surgery improves survival but long term outcome depends on residual shunting and left ventricular function. Residual shunting is common despite apparently successful closure and may require reoperation. Transcatheter closure is an established method of treating selected congenital defects but clinical experience of transcatheter closure in postinfarction ventricular septal rupture is minimal. Transcatheter closure of a residual ventricular septal defect was successfully done using a new device, the Amplatzer septal occluder, in a 50 year old Indian man who had previously undergone emergency surgical repair for postinfarction acute ventricular septal rupture. The technique is described and its potential as a treatment in postinfarction ventricular septal rupture, its possible complications, and the important aspects of case selection and device design are discussed.
引用
收藏
页码:522 / 524
页数:3
相关论文
共 50 条
  • [21] Retrograde transcatheter closure of ventricular septal defect with Amplatzer Duct Occluder II
    Suligoj, Brina
    Cernic, Natasa
    Zorc, Metka
    Noc, Marko
    Kar, Saibal
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2016, 12 (02): : 177 - 178
  • [22] Percutaneous closure of post-infarction ventricular septal defect using an Amplatzer septal occluder
    Tada N.
    Takizawa K.
    Sakurai M.
    Yaginuma G.
    Inoue N.
    Meguro T.
    Cardiovascular Intervention and Therapeutics, 2013, 28 (2) : 216 - 221
  • [23] Outcomes of transcatheter closure of atrial septal defect with a fenestrated Amplatzer Septal Occluder
    Wang, J. -K.
    Lin, M. T.
    Chiu, S. N.
    Chen, C. A.
    Wu, M. H.
    EUROPEAN HEART JOURNAL, 2012, 33 : 270 - 270
  • [24] Transcatheter closure of atrial septal defect using the Amplatzer septal occluder.
    Podolec, P
    Przewlocki, T
    Pieculewicz, M
    Hlawaty, M
    Wilkolek, P
    Tomkiewicz-Pajak, L
    Plazak, W
    Zmudka, K
    Tracz, W
    ACTA CARDIOLOGICA, 2004, 59 (02) : 228 - 229
  • [25] Transcatheter closure of secundum atrial septal defect using an Amplatzer septal occluder
    Kong, XQ
    Cao, KJ
    Yang, R
    Xu, D
    Sheng, YH
    Huang, J
    Ma, WZ
    CHINESE MEDICAL JOURNAL, 2002, 115 (01) : 126 - 128
  • [26] Failed closure of a ventricular septal defect with an Amplatzer occluder
    Wippermann, Jens
    Hoppe, Uta C.
    Sreeram, Narayanswami
    Wahlers, Thorsten
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2010, 10 (02) : 320 - 321
  • [27] Transcatheter Septal Closure of Post-infarction Ventricular Septal Defect Using the Cocoon Ventricular Septal Occluder
    Bisnar, Regina Elena Mandanas
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (15) : S58 - S60
  • [28] Transcatheter closure of a coronary sinus defect with an Amplatzer septal occluder
    Di Bernardo, S
    Fasnacht, M
    Berger, F
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 60 (02) : 287 - 290
  • [29] Comparison of long-term complications of using amplatzer ductal occluder and ventricular septal defect occluder for transcatheter ventricular septal defect closure
    Ghaderian, Mehdi
    Salemi, Negin
    HEART VIEWS, 2021, 22 (02): : 102 - 107
  • [30] Transcatheter closure of perimembranous ventricular septal defect with the Amplatzer® Membranous VSD Occluder 2
    Tzikas, Apostolos
    Aguirre, Daniel
    Velasco-Sanchez, Daniel
    Freixa, Xavier
    Alburquenque, Marcela
    Khairy, Paul
    Bass, John
    Ramirez, Juan
    Ibrahim, Reda
    Miro, Joaquim
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B225 - B225