Development of a Mechanical Scanning Device With High-Frequency Ultrasound Transducer for Ultrasonic Capsule Endoscopy

被引:35
|
作者
Wang, Xingying [1 ]
Seetohul, Vipin [2 ]
Chen, Ruimin [3 ]
Zhang, Zhiqiang [1 ]
Qian, Ming [1 ]
Shi, Zhehao [1 ]
Yang, Ge [1 ]
Mu, Peitian [1 ]
Wang, Congzhi [1 ]
Huang, Zhihong [4 ]
Zhou, Qifa [3 ,5 ]
Zheng, Hairong [1 ]
Cochran, Sandy [2 ]
Qiu, Weibao [1 ]
机构
[1] Chinese Acad Sci, Shenzhen Inst Adv Technol, Paul C Lauterbur Res Ctr Biomed Imaging, Shenzhen 518055, Peoples R China
[2] Univ Glasgow, Sch Engn, Glasgow G12 8QQ, Lanark, Scotland
[3] Univ Southern Calif, Dept Biomed Engn, Los Angeles, CA 90089 USA
[4] Univ Dundee, Inst Med Sci & Technol, Dundee DD2 1FD, Scotland
[5] Univ Southern Calif, Keck Sch Med, Roski Eye Inst, Los Angeles, CA 90033 USA
基金
英国工程与自然科学研究理事会; 美国国家科学基金会;
关键词
Capsule endoscopy; ultrasound; capsule endoscopy; mechanical scanning device; high-FREQUENCY ultrasound; imaging of GI tract; DESIGN; ELASTOGRAPHY; SYSTEM; FUTURE; CHIP;
D O I
10.1109/TMI.2017.2699973
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Wireless capsule endoscopy has opened a new era by enabling remote diagnostic assessment of the gastrointestinal tract in a painless procedure. Video capsule endoscopy is currently commercially available worldwide. However, it is limited to visualization of superficial tissue. Ultrasound (US) imaging is a complementary solutionas it is capable of acquiring transmural information from the tissue wall. This paper presents a mechanical scanning device incorporating a high-frequency transducer specifically as a proof of concept for US capsule endoscopy (USCE), providing information that may usefully assist future research. A rotary solenoid-coil-based motor was employed to rotate the US transducer with sectional electronic control. A set of gears was used to convert the sectional rotation to circular rotation. A single-element focused US transducer with 39-MHz center frequency was used for high-resolution US imaging, connected to an imaging platform for pulse generation and image processing. Key parameters of US imaging for USCE applications were evaluated. Wire phantom imaging and tissue phantom imaging have been conducted to evaluate the performance of the proposed method. A porcine small intestine specimen was also used for imaging evaluation in vitro. Test results demonstrate that the proposed device and rotation mechanism are able to offer good image resolution (similar to 60 mu m) of the lumen wall, and they, therefore, offer a viable basis for the fabrication of a USCE device.
引用
收藏
页码:1922 / 1929
页数:8
相关论文
共 50 条
  • [1] A High-Frequency Mechanical Scanning Ultrasound Imaging System
    Xu, Jie
    Wang, Ninghao
    Chu, Tianxiang
    Yang, Bingqian
    Jian, Xiaohua
    Cui, Yaoyao
    [J]. BIOSENSORS-BASEL, 2023, 13 (01):
  • [2] Development of Broadband High-Frequency Piezoelectric Micromachined Ultrasonic Transducer Array
    Wang, Xu-Bo
    He, Le-Ming
    Ma, You-Cao
    Liu, Wen-Juan
    Xu, Wei-Jiang
    Ren, Jun-Yan
    Riaud, Antoine
    Zhou, Jia
    [J]. SENSORS, 2021, 21 (05) : 1 - 10
  • [3] HIGH-FREQUENCY ULTRASONIC TRANSDUCER OPERATING IN AIR
    TONE, M
    YANO, T
    FUKUMOTO, A
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 1984, 23 (06): : L436 - L438
  • [4] Design of High-frequency Ultrasound Focused Transducer
    Lu Chao
    Jin Cui'e
    Li Ling
    Lu Minghui
    [J]. PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON TEST AUTOMATION & INSTRUMENTATION, VOLS 1 - 4, 2010, : 908 - 913
  • [5] Implementation of an ultrasound biomicroscopy system by rotational scanning of a high-frequency angled needle transducer
    Bok, Tae-Hoon
    Kim, Juho
    Paeng, Dong-Guk
    Bae, Jinho
    Lee, Chong Hyun
    [J]. 2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 2025 - 2028
  • [6] METAL-FILM HIGH-FREQUENCY ULTRASONIC TRANSDUCER
    CHIMENTI, DE
    MAXFIELD, BW
    [J]. JOURNAL OF APPLIED PHYSICS, 1975, 46 (09) : 4073 - 4075
  • [7] Design and Simulation of a High-Frequency Ring-Shaped Linear Array for Capsule Ultrasound Endoscopy
    Lay, Holly S.
    Seetohul, Vipin
    Cox, Ben
    Demore, Christine E. M.
    Cochran, Sandy
    [J]. 2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 683 - 686
  • [8] Systematic study of high-frequency ultrasonic transducer design for laser-scanning photoacoustic ophthalmoscopy
    Ma, Teng
    Zhang, Xiangyang
    Chiu, Chi Tat
    Chen, Ruimin
    Shung, K. Kirk
    Zhou, Qifa
    Jiao, Shuliang
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (01)
  • [9] A Method for High-Frequency Mechanical Scanning Ultrasonic Flow Imaging with Motion Compensation
    Heng, Jiaming
    Li, Chenxi
    Chu, Tianxiang
    Xu, Yiwen
    Jian, Xiaohua
    [J]. DIAGNOSTICS, 2023, 13 (08)
  • [10] Development of a High-frequency Ultrasound System for High-speed Image Scanning
    WU Jian-xing
    CHEN Pei-zhan
    WANG Jian-lin
    CHEN Guan-chun
    CHEN Tai-song
    [J]. Chinese Journal of Biomedical Engineering, 2013, 22 (02) : 79 - 85