Influences of reference plane and direction of measurement on eye aberration measurement

被引:8
|
作者
Atchison, DA
Charman, WN
机构
[1] Queensland Univ Technol, Ctr Hlth Res, Kelvin Grove, Qld 4059, Australia
[2] Univ Manchester, Fac Life Sci, Manchester M60 1QD, Lancs, England
关键词
D O I
10.1364/JOSAA.22.002589
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We explored effects of measurement conditions on wave aberration estimates for uncorrected, axially myopic model eyes. Wave aberrations were initially referenced to either the anterior corneal pole or the natural entrance pupil of symmetrical eye models, with rays traced into the eye from infinity (into the eye) to simulate normal vision, into the eye from infinity and then back out of the eye from the retinal intercepts (into/out of the eye), or out of the eye from the retinal fovea (out of the eye). The into-the-eye and out-of-the-eye ray traces gave increases in spherical aberration as myopia increased, but the into/out-of-the-eye ray trace showed little variation in spherical aberration. Reference plane choice also affected spherical aberration. Corresponding residual aberrations were calculated after the models had been optically corrected, either by placing the object or image plane at the paraxial far point or by modifying corneas to simulate laser ablation corrections. Correcting aberrations by ablation was more complete if the original aberrations were referenced to the cornea rather than to the entrance pupil. For eyes corrected by spectacle lenses, failure to allow for effects of pupil magnification on apparent entrance pupil diameter produced larger changes in measured aberrations. The general findings regarding choice of reference plane and direction of measurement were found to be equally applicable to eyes that lacked rotational symmetry. (c) 2005 Optical Society of America.
引用
收藏
页码:2589 / 2597
页数:9
相关论文
共 50 条
  • [21] A method for linear distance measurement based on reference plane
    Wang, X.-P. (awangxp@163.com), 1600, Sichuan University (45):
  • [22] One Method of Plane Direction Measurement by Using of the Grating Fringe
    Sun, Jie
    Zhang, Zhiling
    FIFTH INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS AND KNOWLEDGE DISCOVERY, VOL 4, PROCEEDINGS, 2008, : 91 - 95
  • [23] IN-SITU MEASUREMENT IN THROUGH-PLANE DIRECTION IN PEMFC
    Ito, Kohei
    Lee, Sangkun
    Yamamoto, Atsushi
    Hirano, Masaaki
    Muramatsu, Hidetaka
    Sasaki, Kazunari
    Ogawa, Kuniyasu
    ICNMM 2009, PTS A-B, 2009, : 1241 - 1247
  • [24] Objective measurement of the off-axis longitudinal chromatic aberration in the human eye
    Rynders, MC
    Navarro, R
    Losada, MA
    VISION RESEARCH, 1998, 38 (04) : 513 - 522
  • [25] Human Eye Aberration Measurement and Correction Based on Micro Adaptive Optics System
    Niu, Saisai
    Shen, Jianxin
    Liang, Chun
    Li, Bangming
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 1203 - 1207
  • [26] Phase Measurement Profilometry Based on a Virtual Reference Plane Method
    Ren, Hongbing
    Lee, Jinlong
    Gao, Xiaorong
    8TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGY: OPTICAL TEST, MEASUREMENT TECHNOLOGY, AND EQUIPMENT, 2016, 9684
  • [27] ABERRATION MEASUREMENT BY CONFOCAL INTERFEROMETRY
    MATTHEWS, HJ
    HAMILTON, DK
    SHEPPARD, CJR
    JOURNAL OF MODERN OPTICS, 1989, 36 (02) : 233 - 250
  • [28] Simulation of eye's wavefront aberration measurement based on annular radial shearing interferometry
    Xu Meng-ting
    Chen Yan-ping
    Zeng Shao-jun
    OPTICAL DESIGN AND TESTING VIII, 2018, 10815
  • [29] Accurate estimation of phase distribution on reference plane in grating projection measurement
    Zhao, MR
    Lin, YC
    Niu, XB
    Cheng, DM
    MEASUREMENT TECHNOLOGY AND INTELLIGENT INSTRUMENTS VI, 2005, 295-296 : 221 - 226
  • [30] VLBI measurement of the secular aberration drift
    Titov, O.
    Lambert, S. B.
    Gontier, A-M
    ASTRONOMY & ASTROPHYSICS, 2011, 529