Influences of reference plane and direction of measurement on eye aberration measurement

被引:8
|
作者
Atchison, DA
Charman, WN
机构
[1] Queensland Univ Technol, Ctr Hlth Res, Kelvin Grove, Qld 4059, Australia
[2] Univ Manchester, Fac Life Sci, Manchester M60 1QD, Lancs, England
关键词
D O I
10.1364/JOSAA.22.002589
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We explored effects of measurement conditions on wave aberration estimates for uncorrected, axially myopic model eyes. Wave aberrations were initially referenced to either the anterior corneal pole or the natural entrance pupil of symmetrical eye models, with rays traced into the eye from infinity (into the eye) to simulate normal vision, into the eye from infinity and then back out of the eye from the retinal intercepts (into/out of the eye), or out of the eye from the retinal fovea (out of the eye). The into-the-eye and out-of-the-eye ray traces gave increases in spherical aberration as myopia increased, but the into/out-of-the-eye ray trace showed little variation in spherical aberration. Reference plane choice also affected spherical aberration. Corresponding residual aberrations were calculated after the models had been optically corrected, either by placing the object or image plane at the paraxial far point or by modifying corneas to simulate laser ablation corrections. Correcting aberrations by ablation was more complete if the original aberrations were referenced to the cornea rather than to the entrance pupil. For eyes corrected by spectacle lenses, failure to allow for effects of pupil magnification on apparent entrance pupil diameter produced larger changes in measured aberrations. The general findings regarding choice of reference plane and direction of measurement were found to be equally applicable to eyes that lacked rotational symmetry. (c) 2005 Optical Society of America.
引用
收藏
页码:2589 / 2597
页数:9
相关论文
共 50 条
  • [1] ABERRATION OF HUMAN EYE AND THEIR MEASUREMENT
    SCHOBER, H
    MUNKER, H
    ZOLLEIS, F
    OPTICA ACTA, 1968, 15 (01): : 47 - &
  • [2] MEASUREMENT OF WAVE ABERRATION IN HUMAN EYE
    SMIRNOV, MS
    BIOPHYSICS-USSR, 1961, 6 (06): : 52 - &
  • [3] Measurement and correction of the eye's chromatic aberration
    Manzanera, S
    Piers, P
    Artal, P
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [4] Information Fusion in Human Eye Aberration Measurement
    Chen, Jiabi
    Zhang, Peiming
    Zhuang, Songlin
    MEASUREMENT TECHNOLOGY AND INTELLIGENT INSTRUMENTS IX, 2010, 437 : 379 - +
  • [5] The application of information fusion in human eye aberration measurement
    Zhang, Peiming
    Chen, Jiabi
    Cao, Liang
    Zhuang, Songlin
    2008 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND APPLICATIONS, 2009, 7160
  • [6] Perceived no reference image quality measurement for chromatic aberration
    Lamb, Anupama B.
    Khambete, Madhuri
    JOURNAL OF ELECTRONIC IMAGING, 2016, 25 (02)
  • [7] MEASUREMENT OF EYE DIRECTION FROM AN UNCLAMPED HEAD
    HUBBELL, PG
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (01): : 196 - &
  • [8] Odd Aberration in Double-Pass Human Eye's Aberration Measurement System
    Deng Yangchun
    Zhao Junlei
    Dai Yun
    Zhang Yudong
    ACTA OPTICA SINICA, 2018, 38 (08)
  • [9] STATE OF ACCOMODATION DURING MEASUREMENT OF AXIAL CHROMATIC ABERRATION OF EYE
    MILLODOT, M
    BOBIER, C
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1976, 53 (04): : 168 - 172
  • [10] An Adaptive Estimating Centroid Method for Measurement of Human Eye Aberration
    Liang, Chun
    Liao, Wenhe
    Shen, Jianxin
    Niu, Saisai
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, VOLS 1-9, 2009, : 3268 - 3272