Determination of ketorolac in human serum by square wave adsorptive stripping voltammetry

被引:17
|
作者
Radi, A [1 ]
Beltagi, AM
Ghoneim, HH
机构
[1] Mansoura Univ, Fac Sci, Dept Chem, Dumyat 34517, Egypt
[2] Fac Educ, Dept Chem, Tanta 33516, Egypt
[3] Tanta Univ, Fac Sci, Dept Chem, Tanta 31527, Egypt
关键词
ketorolac; adsorptive stripping voltammetry; determination in human serum; square wave voltammetry;
D O I
10.1016/S0039-9140(00)00643-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The adsorption behavior of ketorolac on a hanging mercury drop electrode (HMDE) was explored by square-wave and cyclic voltammetry. The square wave voltammetric response of ketorolac depends on the parameters of the square wave voltammetry excitation signal as well as on the pH of the medium and the accumulation time. The drug was accumulated at HMDE and a well-defined peak was obtained at - 1.41 V versus. Ag/AgCl (saturated KCI) in acetate buffer of pH 5.0. A square-wave adsorptive stripping voltammetric method for the quantitative determination of ketorolac was developed. The linear concentration range was 1 x 10(-10)-1 x 10(-8) when using 300 s accumulation at - 0.8 V. The detection limit of ketorolac was 1.0 x 10(-11) M. The precision was excellent with relative standard deviation of 3.85% at concentration of 5 x 10(-8) M after 60 s accumulation time. Applicability to serum samples was illustrated. A detection limit of 14 ng per mi of serum was obtained. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:283 / 289
页数:7
相关论文
共 50 条
  • [1] Determination of lansoprazole in human serum by square wave adsorptive stripping voltammetry
    Radi, A
    [J]. ANALYTICAL LETTERS, 2002, 35 (15) : 2449 - 2458
  • [2] Determination of nifedipine in human plasma by square wave adsorptive stripping voltammetry
    Özaltin, N
    Yardimci, C
    Süslü, I
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (03) : 573 - 582
  • [3] Determination of cefonicid in human urine by adsorptive square-wave stripping voltammetry
    Radi, A
    Wahdan, T
    Abd El-Ghany, N
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (06) : 1041 - 1046
  • [4] Determination of salmon calcitonin by square wave adsorptive stripping voltammetry
    Osteryoung, JG
    Wikiel, KJ
    [J]. ANALYTICA CHIMICA ACTA, 1997, 351 (1-3) : 65 - 71
  • [5] DETERMINATION OF TETRAMETHRIN BY ADSORPTIVE STRIPPING WITH SQUARE-WAVE VOLTAMMETRY
    HERNANDEZ, P
    GALANESTELLA, F
    HERNANDEZ, L
    [J]. ELECTROANALYSIS, 1992, 4 (01) : 45 - 49
  • [6] Determination of Donepezil Hydrochloride in Pharmaceutical Formulation and Human Serum by Square-Wave Adsorptive Cathodic Stripping Voltammetry
    Ghoneim, Enass M.
    El-Attar, Mona A.
    Ghoneim, Mohamed M.
    [J]. CHEMIA ANALITYCZNA, 2009, 54 (03): : 389 - 402
  • [7] Determination of nifuroxazide in human serum by adsorptive stripping voltammetry
    Radi, A
    El Ries, MA
    [J]. ANALYTICAL SCIENCES, 1999, 15 (04) : 385 - 388
  • [8] Determination of Nifuroxazide in Human Serum by Adsorptive Stripping Voltammetry
    A. Radi
    M. A. El Ries
    [J]. Analytical Sciences, 1999, 15 : 385 - 388
  • [9] Determination of tryptamine in foods using square wave adsorptive stripping voltammetry
    Costa, Daniel J. E.
    Martinez, Ana M.
    Ribeiro, Williame F.
    Bichinho, Katia M.
    Susana Di Nezio, Maria
    Pistonesi, Marcelo F.
    Araujo, Mario C. U.
    [J]. TALANTA, 2016, 154 : 134 - 140
  • [10] Determination of Fluoroquinolone Antibacterial Agents by Square Wave Adsorptive Stripping Voltammetry
    Boo, Hankil
    Song, Youn Joo
    Park, Sejin
    Chung, Taek Dong
    [J]. JOURNAL OF THE KOREAN ELECTROCHEMICAL SOCIETY, 2010, 13 (01): : 63 - 69