Determination of nifuroxazide in human serum by adsorptive stripping voltammetry

被引:24
|
作者
Radi, A [1 ]
El Ries, MA
机构
[1] Mansoura Univ, Fac Sci, Dept Chem, Demiatta 34517, Egypt
[2] Natl Org Drug Control & Res, Cairo 29, Egypt
关键词
nifuroxazide; adsorptive stripping voltammetry;
D O I
10.2116/analsci.15.385
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The adsorption behavior of nifuroxazide on a hanging mercury drop electrode (HMDE) was critically examined using cyclic voltammetry and differential pulse techniques. The effect of different parameters on the accumulation behavior of the adsorbed species was tested. Thus, a sensitive stripping voltammetry procedure for the determination of nifuroxazide with an adsorptive accumulation on the surface of HMDE has been developed. Under optimal conditions a detection limit of 5x10(-9) M and a linear calibration graph in the range 2x10(-8) - 1x10(-7) M were obtained. The precision, expressed by the relative standard deviation, was 2.8% (n=10) at 1x10(-7) M. The method was successfully applied for the analysis of nifuroxazide in serum.