Angular distribution of diffuse reflectance in biological tissue

被引:15
|
作者
Xia, Jinjun [1 ]
Yao, Gang [1 ]
机构
[1] Univ Missouri, Dept Biol Engn, Columbia, MO 65211 USA
关键词
D O I
10.1364/AO.46.006552
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We measured angular-resolved diffuse reflectance in tissue samples of different anisotropic characteristics. Experimental measurements were compared with theoretical results based on the diffusion approximation. The results indicated that the angular distribution in isotropic tissue was the same as in isotropic phantoms. Under normal incidence, the measured angular profiles of diffuse reflectance approached the Lambertian distribution when the evaluation location was far away from the incident point. The skewed angular profiles observed under oblique incidence could be explained using the diffuse model. The anisotropic tissue structures in muscle showed clear effects on the measurements especially at locations close to the light incidence. However, when measuring across the muscle fiber orientations, the results were in good agreement with those obtained in isotropic samples. (c) 2007 Optical Society of America.
引用
收藏
页码:6552 / 6560
页数:9
相关论文
共 50 条
  • [21] Determination of tissue oxygen saturation by diffuse reflectance spectroscopy
    Sanchez-Ramos, Laura Lucia
    Morales-Cruzado, Beatriz
    Perez-Gutierrez, Francisco Gerardo
    JOURNAL OF BIOMEDICAL OPTICS, 2023, 28 (09)
  • [23] Spectral and geometrical variation of the bidirectional reflectance distribution function of diffuse reflectance standards
    Ferrero, Alejandro
    Maria Rabal, Ana
    Campos, Joaquin
    Pons, Alicia
    Luisa Hernanz, Maria
    APPLIED OPTICS, 2012, 51 (36) : 8535 - 8540
  • [24] Study of drug distribution of granules with diffuse reflectance spectroscopy
    Zelkó, R
    Antal, I
    Dredán, J
    Dávid, AZ
    Rácz, I
    STP PHARMA SCIENCES, 2000, 10 (03): : 210 - 212
  • [25] Spatially resolved absolute diffuse reflectance measurements for noninvasive determination of the optical scattering and absorption coefficients of biological tissue
    Kienle, A
    Lilge, L
    Patterson, MS
    Hibst, R
    Steiner, R
    Wilson, BC
    APPLIED OPTICS, 1996, 35 (13): : 2304 - 2314
  • [26] Mueller matrix bidirectional reflectance distribution function measurements and modeling of diffuse reflectance standards
    Germer, Thomas A.
    Patrick, Heather J.
    POLARIZATION SCIENCE AND REMOTE SENSING V, 2011, 8160
  • [27] Diffuse reflectance spectroscopy of the cartilage tissue in the fourth optical window
    Nazarov, Dmitriy A.
    Denisenko, Georgy M.
    Budylin, Gleb S.
    Kozlova, Elizaveta A.
    Lipina, Marina M.
    Lazarev, Vladimir A.
    Shirshin, Evgeny A.
    Tarabrin, Mikhail K.
    BIOMEDICAL OPTICS EXPRESS, 2023, 14 (04): : 1509 - 1521
  • [28] Retrieval of chromophore concentration in a tissue phantom by diffuse reflectance spectroscopy
    A. Sircan-Kucuksayan
    M. Canpolat
    Optics and Spectroscopy, 2014, 117 : 663 - 669
  • [29] Quantification of tissue oxygenation levels using diffuse reflectance spectroscopy
    Anand, Suresh B. S.
    Sujatha, N.
    PHOTONICS 2010: TENTH INTERNATIONAL CONFERENCE ON FIBER OPTICS AND PHOTONICS, 2011, 8173
  • [30] Second derivative diffuse reflectance spectroscopy for estimating tissue hypoxia
    Bachir, Wesam
    Hamadah, Omar
    OSA CONTINUUM, 2021, 4 (02): : 650 - 664