An experimental study on the performance of new glass curtain wall system in different seasons

被引:4
|
作者
Feng, Chaoqing [1 ]
Ma, Fengge [1 ]
Wang, Rui [2 ]
Xu, Zhao [1 ]
Zhang, Lizhuang [1 ]
Zhao, Mingzhi [1 ]
机构
[1] Inner Mongolia Univ Technol, Coll Energy & Power Engn, Hohhot 010051, Peoples R China
[2] China Natl Inst Standardizat, Beijing 100081, Peoples R China
基金
中国国家自然科学基金;
关键词
Glass curtain wall; Building integrated photovoltaics; Indoor heat load; Photovoltaic photothermal utilization; CONCENTRATOR; DESIGN; WINDOW; SAVINGS; ENERGY;
D O I
10.1016/j.buildenv.2022.109222
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A new type of glass curtain wall system based on transmission solar concentrator is proposed. The device effectively improves the incidence of solar radiation on the unit area of the battery and maximizes the use of excess solar radiation to generate electricity and heat while continuing to ensure indoor lighting. It can also convert excess solar energy into electrical energy, reduce the indoor thermal load, and generate heat, which can be used to improve efficiency and reduce energy consumption. The device's performance was tested experimentally in different seasons under actual weather conditions. The integral box was designed based on the integrating sphere principle and the temperature, illuminance, inlet and outlet temperature of the cooling medium in the integral box of the new glass curtain wall system were all tested in different seasons throughout the day. The comparison test was carried out using ordinary double-layer vacuum glass. The results show that the new glass curtain wall system's thermal efficiency is generally the highest at noon, while the maximum heat gain per unit area of air per day can reach 149 W/m(2) in spring and autumn, 237 W/m(2) in summer, and 52.6 W/m(2) in winter. During spring, autumn and summer, glass, the new glass curtain wall can reduce the heat load in the integral box by more than 41% on average over the whole day with high efficiency. At the same time, the international lighting standards show that workers are generally fully satisfied when the indoor illuminance is more than 500 Lux, and the illuminance of this new glass curtain wall system is more than 500 Lux in all seasons. Additionally, it can reduce the needed indoor lighting better than ordinary double-layer vacuum glass.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Design of Structure and Drive System for Pneumatic Glass Curtain Wall Cleaning Robot
    Tang, Dedong
    Cui, Mingyang
    Zhang, Jialiang
    Chu, Jingfeng
    Li, Bin
    [J]. INDUSTRIAL INSTRUMENTATION AND CONTROL SYSTEMS II, PTS 1-3, 2013, 336-338 : 1068 - 1071
  • [22] Experimental Study on the In-Plane Seismic Performance of a New Type of Masonry Wall System
    Choi, Ho
    Lee, Kang-Seok
    [J]. APPLIED SCIENCES-BASEL, 2020, 10 (24): : 1 - 15
  • [23] The Vision Orientation System Based on OpenCV of the Glass Curtain Wall Cleaning Robot
    Zhang, Dongping
    Huang, Yuanliang
    Chen, Jiahao
    Luo, Xianghua
    [J]. INDUSTRIAL INSTRUMENTATION AND CONTROL SYSTEMS II, PTS 1-3, 2013, 336-338 : 1063 - 1067
  • [24] Glass Curtain Wall Technology and Sustainability in Commercial Buildings in Auckland, New Zealand
    Wu, Yi
    Flemmer, Claire
    [J]. INTERNATIONAL JOURNAL OF BUILT ENVIRONMENT AND SUSTAINABILITY, 2020, 7 (02): : 57 - 65
  • [25] Characterizing the generation and management of a new construction waste in China: glass curtain wall
    Mao, Ruichang
    Duan, Huabo
    Gao, Hongguang
    Wu, Huanyu
    [J]. SELECTED PROCEEDINGS OF THE TENTH INTERNATIONAL CONFERENCE ON WASTE MANAGEMENT AND TECHNOLOGY, 2016, 31 : 204 - 210
  • [26] Thermal insulation, power generation, lighting and energy saving performance of heat insulation solar glass as a curtain wall application in Taiwan: A comparative experimental study
    Cuce, Erdem
    Riffat, Saffa B.
    Young, Chin-Huai
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2015, 96 : 31 - 38
  • [27] A comparative life cycle assessment of a transparent composite facade system and a glass curtain wall system
    Kim, Kyoung-Hee
    [J]. ENERGY AND BUILDINGS, 2011, 43 (12) : 3436 - 3445
  • [28] Analysis on Integral Performance of Unit Glazing Curtain Wall Considering the Contribution of Glass Rigidity
    Gao, Yongtao
    Hu, Xiao
    [J]. ADVANCES IN STRUCTURES, PTS 1-5, 2011, 163-167 : 2454 - 2458
  • [29] Energy-saving performance of respiration-type double-layer glass curtain wall system in different climate zones of China: Experiment and simulation
    Kong, Xiangfei
    Ren, Yue
    Ren, Jianlin
    Duan, Shasha
    Guo, Chenli
    [J]. ENERGY AND BUILDINGS, 2021, 252
  • [30] Thermal Performance Effect of Glass curtain-wall on Office Buildings Energy Consumption from Different Climatic Regions in China
    Yi, Jianguang
    [J]. RENEWABLE AND SUSTAINABLE ENERGY, PTS 1-7, 2012, 347-353 : 1470 - 1478