共 50 条
Dentin bond strength of packable composites using one-bottle adhesives
被引:0
|作者:
Jang, KT
Mejía, FA
García-Godoy, F
机构:
[1] Univ Texas, Hlth Sci Ctr, Dept Restorat Dent, San Antonio, TX 78229 USA
[2] Seoul Natl Univ, Dept Pediat Dent, Seoul, South Korea
来源:
关键词:
D O I:
暂无
中图分类号:
R78 [口腔科学];
学科分类号:
1003 ;
摘要:
Purpose: To evaluate the shear bond strength to dentin of packable composites using their respective one-bottle adhesives. Materials and Methods: Human, noncarious extracted permanent molars stored in distilled water were used. Flat buccal and lingual dentin surfaces were ground wet on 600-grit silicon carbide paper. The teeth were then distributed at random into four groups of 8 teeth (16 surfaces) each: Group 1: Gluma Comfort Bond/Solitaire II; Group 2: Bond 1/Alert; Group 3: Prime & Bond NT/Surefil; Group 4: OptiBond Solo/Prodigy Condensable. Group 5: Single Bond/Z250 (control) Cylindrical samples of the materials were prepared in plastic molds and bonded to the dentin surface according to the manufacturers' instructions. Ail samples were placed in distilled water for 24 hrs, thermocycled for 500 cycles in distilled water at 6 degreesC and 60 degreesC and sheared with a universal testing machine at a crosshead speed of 0.5 mm/min. Results: In MPa: Group 1: 24.39 +/- 3.54; Group 2: 28.96 +/- 4.62; Group 3: 30.77 +/- 4.71; Group 4: 30.82 +/- 3.29; Group 5: 24.93 +/- 5.14. ANOVA revealed that Groups 1 and 2 were statistically significantly different from the other groups; there was no statistically significant difference between Groups 2, 3 and 4.
引用
收藏
页码:308 / 310
页数:3
相关论文