High frequency thermoacoustically driven pulse tube coolers (PTCs) have the advantages of high energy density, compact structure, and high reliability. Through a series of improvements, the 300 Hz thermoacoustically driven PTC in this paper achieved a fourfold increase in the cooling power compared with that in our last report. A cooling power of 1.04 W at 80 K and a no-load temperature of 63 K are obtained with 500 W heating power. In the system, the acoustic pressure amplifier tube (APAT) plays an important role in coupling the thermoacoustic engine and the PTC. The effects of APAT on the system performance are investigated here through both numeric simulations and experiments. The simulation indicates that length of the APAT is limited due to impedance match requirement between the PTC and the engine, which is partly evidenced by experiments. Calculation also gives a good agreement between calculated pressure wave amplification ratio and experimental values. APAT with different lengths and diameters are investigated through experiments which indicate that there is an optimum diameter for the system performance. (C) 2010 American Institute of Physics. [doi:10.1063/1.3484046]
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Cryogenic-temperature thermoacoustically driven pulse tube refrigerator
    Jin, T
    Chen, GB
    Shen, Y
    Huang, YH
    Wu, ZH
    [J]. ADVANCES IN CRYOGENIC ENGINEERING, VOL 47, PTS A AND B, 2002, 613 : 836 - 843
  • [22] Investigation on 300 Hz pulse tube cryocooler
    Technical Institute of Physics and Chemistry, Chinese Acad. of Sci., Beijing 100190, China
    不详
    [J]. Kung Cheng Je Wu Li Hsueh Pao, 2008, 7 (1099-1102): : 1099 - 1102
  • [23] An innovative configuration for thermoacoustically-driven pulse tube coolers
    Hu, JY
    Luo, EC
    Dai, W
    [J]. CRYOGENICS, 2005, 45 (07) : 523 - 527
  • [24] Pressure drop in pulse tube cooler components
    Chen, HE
    Bennett, JH
    Yoshida, S
    Le, A
    Frederking, THK
    [J]. CRYOCOOLERS 10, 1999, : 275 - 280
  • [25] Thermoacoustically driven pulse tube refrigeration below 90K
    Tang, K.
    Chen, G. B.
    Jin, T.
    Bao, R.
    [J]. ICEC 20: PROCEEDINGS OF THE TWENTIETH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE, 2005, : 387 - 390
  • [26] A HIGH FREQUENCY THERMOACOUSTICALLY-DRIVEN PULSE TUBE CRYOCOOLER WITH COAXIAL RESONATOR
    Yu, G. Y.
    Wang, X. T.
    Dai, W.
    Luo, E. C.
    [J]. ADVANCES IN CRYOGENIC ENGINEERING, VOLS 55A AND 55B, 2010, 1218 : 191 - 198
  • [27] Developing an augmented onset model for a thermoacoustically-driven, pulse tube cryocooler
    Bahrami, Mohsen
    Ommi, Fathollah
    [J]. SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2021, 47
  • [28] A thermoacoustically driven pulse tube refrigerator capable of working below 120 K
    Jin, T
    Chen, GB
    Shen, Y
    [J]. CRYOGENICS, 2001, 41 (08) : 595 - 601
  • [29] Miniature pulse tube cooler
    Tward, E
    Nguyen, T
    Godden, J
    Toma, G
    [J]. ADVANCES IN CRYOGENIC ENGINEERING, VOLS. 49A AND B, 2004, 710 : 1326 - 1329
  • [30] Performance of a 260 Hz pulse tube cooler with metal fiber as the regenerator material
    Wang, Xiaotao
    Zhang, Shuang
    Yu, Guoyao
    Dai, Wei
    Luo, Ercang
    [J]. ADVANCES IN CRYOGENIC ENGINEERING, 2014, 1573 : 576 - 581