Influence of acoustic pressure amplifier tube on a 300 Hz thermoacoustically driven pulse tube cooler

被引:6
|
作者
Wang, Xiaotao [1 ,2 ]
Yu, Guoyao [1 ]
Dai, Wei [1 ]
Luo, Ercang [1 ]
Zhou, Yuan [1 ]
机构
[1] Chinese Acad Sci, Tech Inst Phys & Chem, Key Lab Cryogen, Beijing 100190, Peoples R China
[2] Chinese Acad Sci, Grad Sch, Beijing 100039, Peoples R China
基金
中国国家自然科学基金;
关键词
ENGINE;
D O I
10.1063/1.3484046
中图分类号
O59 [应用物理学];
学科分类号
摘要
High frequency thermoacoustically driven pulse tube coolers (PTCs) have the advantages of high energy density, compact structure, and high reliability. Through a series of improvements, the 300 Hz thermoacoustically driven PTC in this paper achieved a fourfold increase in the cooling power compared with that in our last report. A cooling power of 1.04 W at 80 K and a no-load temperature of 63 K are obtained with 500 W heating power. In the system, the acoustic pressure amplifier tube (APAT) plays an important role in coupling the thermoacoustic engine and the PTC. The effects of APAT on the system performance are investigated here through both numeric simulations and experiments. The simulation indicates that length of the APAT is limited due to impedance match requirement between the PTC and the engine, which is partly evidenced by experiments. Calculation also gives a good agreement between calculated pressure wave amplification ratio and experimental values. APAT with different lengths and diameters are investigated through experiments which indicate that there is an optimum diameter for the system performance. (C) 2010 American Institute of Physics. [doi:10.1063/1.3484046]
引用
收藏
页数:5
相关论文
共 50 条
  • [1] A 300 Hz high frequency thermoacoustically driven pulse tube cooler
    ZHU ShangLong1
    2 Graduate University of Chinese Academy of Sciences
    [J]. Science Bulletin, 2008, (08) : 1270 - 1271
  • [2] Characterization of a 300 Hz thermoacoustically-driven pulse tube cooler
    Zhu, S. L.
    Yu, G. Y.
    Dai, W.
    Luo, E. C.
    Wu, Z. H.
    Zhang, X. D.
    [J]. CRYOGENICS, 2009, 49 (01) : 51 - 54
  • [3] A 300 Hz high frequency thermoacoustically driven pulse tube cooler
    Zhu ShangLong
    Yu GuoYao
    Zhang XiaoDong
    Dai Wei
    Luo ErCang
    Zhou Yuan
    [J]. CHINESE SCIENCE BULLETIN, 2008, 53 (08): : 1270 - 1271
  • [4] 300 Hz thermoacoustically driven pulse tube cooler for temperature below 100 K
    Dai, Wei
    Yu, Guoyao
    Zhu, Shanglong
    Luo, Ercang
    [J]. APPLIED PHYSICS LETTERS, 2007, 90 (02)
  • [5] COUPLING RESEARCH IN THE THERMOACOUSTICALLY DRIVEN PULSE TUBE COOLER
    Zhou, G.
    Huang, X.
    Li, Z. Y.
    [J]. ADVANCES IN CRYOGENIC ENGINEERING, VOLS 57A AND 57B, 2012, 1434 : 467 - 474
  • [6] Thermoacoustically driven pulse tube refrigeration below 80 K by introducing an acoustic pressure amplifier
    Bao, Rui
    Chen, Guobang
    Tang, Ke
    Cao, Weihua
    Jin, Tao
    [J]. APPLIED PHYSICS LETTERS, 2006, 89 (21)
  • [7] A thermoacoustically-driven pulse tube cryocryocooler operating around 300Hz
    Yu, G. Y.
    Zhu, S. L.
    Dai, W.
    Luo, E. C.
    [J]. ADVANCES IN CRYOGENIC ENGINEERING, VOLS 53A AND 53B, 2008, 985 : 1659 - 1666
  • [8] Study on cold head structure of a 300 Hz thermoacoustically driven pulse tube cryocooler
    Yu, G. Y.
    Wang, X. T.
    Dai, W.
    Luo, E. C.
    [J]. CRYOGENICS, 2012, 52 (4-6) : 212 - 215
  • [9] Thermoacoustically driven pulse tube coolers with acoustic amplifiers
    Hu, J. Y.
    Dai, W.
    Luo, E. C.
    [J]. ADVANCES IN CRYOGENIC ENGINEERING, VOLS 51A AND B, 2006, 823 : 1564 - +
  • [10] A novel coupling configuration for thermoacoustically-driven pulse tube coolers: Acoustic amplifier
    DAI Wei1
    2. Graduate School of Chinese Academy of Sciences
    [J]. Science Bulletin, 2005, (18) : 146 - 148