The test of a full-scale three-story RC structure with masonry infill walls

被引:103
|
作者
Pujol, S. [1 ]
Fick, D. [2 ]
机构
[1] Purdue Univ, W Lafayette, IN 47907 USA
[2] S Dakota Sch Mines & Technol, Rapid City, SD 57701 USA
关键词
Masonry; Infill; Walls; Reinforced concrete; Cyclic load; Drift capacity; Earthquake; Strength; Stiffness; Full-scale; REINFORCED-CONCRETE FRAMES; SEISMIC RESPONSE; BUILDINGS; PERFORMANCE; EARTHQUAKE; DESIGN; PANELS;
D O I
10.1016/j.engstruct.2010.05.030
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Masonry infill walls are used as partitions in many countries. There is no consensus on whether infill walls make a reinforced concrete frame more or less vulnerable to the effects of strong ground motion. To provide hard evidence to address this question, a full-scale three-story reinforced-concrete structure was tested with and without infill walls made out of solid clay bricks. During the test without the walls, the structure experienced a punching shear failure at a slab-column connection. After this first test, infill walls were built with solid bricks. The walls filled completely full bays and ran continuously from the foundation to the roof. It was observed that the walls increased the stiffness and the strength of the structure. The drift capacity of the structure with walls was observed to be 1.5%. Up to this level of deformation, masonry infill walls in structures similar to the one described here can be expected to help control inter-story drift provided that measures are taken to prevent their out-of-plane failure. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3112 / 3121
页数:10
相关论文
共 50 条
  • [1] Dynamic Tests of a Large-Scale Three-Story RC Structure with Masonry Infill Walls (vol 24, pg 1675, 2018)
    Guljas, Ivica
    Penava, Davorin
    Laughery, Lucas
    Pujol, Santiago
    [J]. JOURNAL OF EARTHQUAKE ENGINEERING, 2020, 24 (11) : I - I
  • [3] Shake-Table Tests of a Full-Scale Three-Story Reinforced Masonry Shear Wall Structure
    Stavridis, A.
    Ahmadi, F.
    Mavros, M.
    Shing, P. B.
    Klingner, R. E.
    McLean, D.
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (10)
  • [4] Shake-table tests of a three-story reinforced concrete frame with masonry infill walls
    Stavridis, Andreas
    Koutromanos, I.
    Shing, P. B.
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2012, 41 (06): : 1089 - 1108
  • [5] Response of Full-Scale Three-Story Flat-Plate Test Structure to Cycles of Increasing Lateral Load
    Fick, Damon R.
    Sozen, Mete A.
    Kreger, Michael E.
    [J]. ACI STRUCTURAL JOURNAL, 2017, 114 (06) : 1507 - 1517
  • [6] Full-scale burn tests of wooden three-story apartment building
    Hayashi, Y
    Hasemi, Y
    Nakamura, K
    Hokugo, A
    Hagiwara, I
    Motegi, T
    Yamana, T
    Yoshida, M
    Goto, T
    Wakamatsu, T
    Sugawa, O
    Ohmiya, Y
    Akabane, N
    Abe, I
    Izumi, J
    Fukumoto, M
    Saito, H
    [J]. COST ACTION E5 WORKSHOP ON FIRE SAFETY OF MEDIUM-RISE TIMBER FRAME RESIDENTIAL BUILDINGS, 1998, 179 : 100 - 126
  • [7] Full-Scale Test on Seismic Performance of Masonry Structure
    An, Dong
    Qu, Tiejun
    Liang, Jianwen
    [J]. PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING, PTS. 1-5, 2012, 204-208 : 2610 - +
  • [8] Shaking Table Testing of a Full-Scale Prefabricated Three-Story Timber-Frame Building
    Tomasi, Roberto
    Sartori, Tiziano
    Casagrande, Daniele
    Piazza, Maurizio
    [J]. JOURNAL OF EARTHQUAKE ENGINEERING, 2015, 19 (03) : 505 - 534
  • [9] Effect of variation on infill masonry walls in the seismic performance of soft story RC building
    Pokhrel, Ashok
    Gautam, Dipendra
    Chaulagain, Hemchandra
    [J]. AUSTRALIAN JOURNAL OF STRUCTURAL ENGINEERING, 2019, 20 (01) : 1 - 9
  • [10] Full-scale validation of CFD simulations of buoyancy-driven ventilation in a three-story office building
    Chen, Chen
    Gorle, Catherine
    [J]. BUILDING AND ENVIRONMENT, 2022, 221