Full-Scale Test on Seismic Performance of Masonry Structure

被引:1
|
作者
An, Dong [1 ]
Qu, Tiejun [2 ]
Liang, Jianwen [1 ]
机构
[1] Tianjin Univ, Sch Civil Engn, Tianjin 300072, Peoples R China
[2] North China Univ Technol, Coll Architecture & Civil Engn, Beijing 100144, Peoples R China
关键词
Tie-column; Ring-beam; Pseudo-dynamic test; Seismic performance; Stiffness degradation;
D O I
10.4028/www.scientific.net/AMM.204-208.2610
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
For further study on effective seismic design requirements of masonry structure, two masonry buildings were designed and constructed according to common structure style in towns and villages. Two full-scale buidings were subjected to earthquake using pseudo-dynamic test and quasi-static test. This paper presents crack propagation of masonry structure, hysteretic behavior, deformation and stiffness degradation under horizontal seismic action. In this experiment, deformability and ultimate bearing capacity of confined masonry (CM) with tie-column and ring-beam is higher than common brick structure (BM). Confined masonry (CM) wall maintain integrity due to constraint of tie-column and ring-beam. These tests verify that tie-column and ring-beam system is an effective seismic requirement to enhance seismic performance of masonry structure.
引用
收藏
页码:2610 / +
页数:2
相关论文
共 50 条
  • [1] Seismic Performance of Different Masonry Buildings: Full-Scale Experimental Study
    Chourasia, Ajay
    Bhattacharyya, S. K.
    Bhandari, N. M.
    Bhargava, Pradeep
    [J]. JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2016, 30 (05)
  • [2] Seismic Damage Detection of a Full-Scale Shaking Table Test Structure
    Ji, Xiaodong
    Fenves, Gregory L.
    Kajiwara, Kouichi
    Nakashima, Masayoshi
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2011, 137 (01) : 14 - 21
  • [3] Shaking Table Test of Water Supply Pipes Installed in a Full-Scale Masonry Structure
    Houli Wu
    Endong Guo
    Dezhang Sun
    Chenxi Mao
    Haoyu Zhang
    Zhibin Liu
    [J]. KSCE Journal of Civil Engineering, 2022, 26 : 824 - 836
  • [4] Shaking Table Test of Water Supply Pipes Installed in a Full-Scale Masonry Structure
    Wu, Houli
    Guo, Endong
    Sun, Dezhang
    Mao, Chenxi
    Zhang, Haoyu
    Liu, Zhibin
    [J]. KSCE JOURNAL OF CIVIL ENGINEERING, 2022, 26 (02) : 824 - 836
  • [5] The test of a full-scale three-story RC structure with masonry infill walls
    Pujol, S.
    Fick, D.
    [J]. ENGINEERING STRUCTURES, 2010, 32 (10) : 3112 - 3121
  • [6] Comparative Analysis of the Seismic Performance of a Full-Scale Historical Timber Structure by Numerical Simulation and Mechanical Test
    Chen, Jinyong
    Li, Tieying
    Yang, Qingshan
    Niu, Qingfang
    Shi, Xiwang
    Meng, Xianjie
    Wan, Jia
    Zhao, Yanxia
    [J]. INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2024, 18 (05) : 740 - 749
  • [7] Testing of a full-scale unreinforced masonry building following seismic strengthening
    Moon, Franklin L.
    Yi, Tianyi
    Leon, Roberto T.
    Kahn, Lawrence F.
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2007, 133 (09): : 1215 - 1226
  • [8] Seismic Performance of Strengthened Slab-Column Connections in a Full-Scale Test
    Ramos, Antonio Pinho
    Isufi, Brisid
    Marreiros, Rui
    Coronelli, Dario
    Netti, Teresa
    Lamperti Tornaghi, Marco
    Tsionis, Georgios
    Muttoni, Aurelio
    [J]. JOURNAL OF EARTHQUAKE ENGINEERING, 2023, 27 (09) : 2299 - 2318
  • [9] Experimental seismic performance of a full-scale unreinforced clay-masonry building with flexible timber diaphragms
    Kallioras, Stylianos
    Guerrini, Gabriele
    Tomassetti, Umberto
    Marchesi, Beatrice
    Penna, Andrea
    Graziotti, Francesco
    Magenes, Guido
    [J]. ENGINEERING STRUCTURES, 2018, 161 : 231 - 249
  • [10] Seismic performance evaluation of full-scale confined masonry building using light weight cellular panels
    Chourasia, Ajay
    Singhal, Shubham
    Parashar, Jalaj
    [J]. JOURNAL OF BUILDING ENGINEERING, 2020, 32