A spectrum estimation approach for accurate heartbeat detection using Doppler radar based on combination of FTPR and TWV

被引:4
|
作者
Pan, Haipeng [1 ,2 ]
Zou, Yongyang [1 ]
Gu, Minming [1 ]
机构
[1] Zhejiang Sci Tech Univ, Sch Informat Sci & Engn, Hangzhou 310018, Peoples R China
[2] Zhejiang Sci Tech Univ, Automat Dept, Hangzhou 310018, Peoples R China
关键词
Doppler radar; Heart rate (HR); Frequency-time phase regression (FTPR); Time-window-variation (TWV); MATCHED-FILTER; NONCONTACT; CLASSIFICATION; SYSTEMS;
D O I
10.1186/s13634-022-00899-8
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Non-contact heartbeat detection using Doppler radar is extremely valuable for remotely monitoring and medical diagnosis on special occasions. Nevertheless, fast and accurate heart rate (HR) detection endures several challenges due to influential respiration interference and insufficient frequency spectrum resolution. In this paper, a novel heartbeat detection method with a compact Doppler radar is employed to accurately estimate some indicators of HR and heart rate variability. Firstly, a multiresolution analysis approach based on maximal overlap discrete wavelet transform is introduced to accomplish the preliminary separation of respiration and heartbeat. Subsequently, a template matched filter algorithm is further implemented to maximize the enhancement of the concealed heartbeat component and retrieve the heartbeat signal. Eventually, a novel spectrum estimation method combining frequency-time phase regression with time-window-variation technology is proposed to evaluate the real-time HR. It solves serious dominant frequency estimation deviation and insufficient frequency spectrum resolution in short-period time windows. The accuracy and timeliness of our proposed method are validated by 6 sets of experimental data sampled at the actual office. As a result, the HR detection accuracy is up to 99.70% in different-period time windows of 10 s and 92.09% in 3s. In addition, the mean relative error of extracted beat-to-beat intervals in 3 s ranges from 0.76 to 1.02%.
引用
收藏
页数:22
相关论文
共 50 条
  • [31] Doppler Spectrum Parameter Estimation for Weather Radar Echoes Using a Parametric Semianalytical Model
    Dash, Tworit
    Driessen, Hans
    Krasnov, Oleg A.
    Yarovoy, Alexander
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2024, 62 : 1 - 18
  • [32] Radar Micro-Doppler-based Rotary Drone Detection using Parametric Spectral Estimation Methods
    Huang, Andi
    Sevigny, Pascale
    Balajit, Bhashyam
    Rajan, Sreeraman
    2020 IEEE SENSORS, 2020,
  • [33] Range-Doppler Spectrum Estimation Based on Matrix Completion for Frequency Agile Radar
    Hu, Xueyao
    Lu, Fugang
    Liang, Can
    Liu, Jianhu
    Wang, Yanhua
    2020 IEEE RADAR CONFERENCE (RADARCONF20), 2020,
  • [34] Passive Radar for Low Doppler Targets Detection using Background Estimation and Subtraction
    Zhang, Lu
    Bialkowski, Konstanty S.
    PROCEEDINGS OF THE 2019 IEEE ASIA-PACIFIC MICROWAVE CONFERENCE (APMC), 2019, : 189 - 191
  • [35] Doppler Frequency Components Estimation From Range-Doppler Spectrum Using Shipboard Coherent Microwave Radar
    Wu, Sitao
    Zhao, Chen
    Chen, Zezong
    Xu, Qinghui
    Wang, Xiao
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2024, 62 : 1 - 12
  • [36] Compressed Sensing based Range Detection and Doppler Estimation for Portable Surveillance Radar
    Chandrakanth, V
    Merchant, S. N.
    2016 17TH INTERNATIONAL RADAR SYMPOSIUM (IRS), 2016,
  • [37] A MACHINE LEARNING BASED APPROACH TO WEATHER PARAMETER ESTIMATION IN DOPPLER WEATHER RADAR
    Kon, Satoshi
    Tanaka, Toshihisa
    Mizutani, Humihiko
    Wada, Masakazu
    2011 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, 2011, : 2152 - 2155
  • [38] High Accuracy Heartbeat Detection from CW-Doppler Radar Using Singular Value Decomposition and Matched Filter
    Iwata, Yuki
    Thanh, Han Trong
    Sun, Guanghao
    Ishibashi, Koichiro
    SENSORS, 2021, 21 (11)
  • [39] Technique of Tracking Multiple Pedestrians Using Monostatic Ultra-wideband Doppler Radar with Adaptive Doppler Spectrum Estimation
    Okumura, Shigeaki
    Sato, Takuro
    Sakamoto, Takuya
    Sato, Toru
    2016 INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION (ISAP), 2016, : 320 - 321
  • [40] Accurate Doppler radar-based heart rate measurement using matched filter
    Yang, Zi-Kai
    Zhao, Sheng
    Huang, Xiang-Dong
    Lu, Wei
    IEICE ELECTRONICS EXPRESS, 2020, 17 (08):