Evaluation of deformation accuracy of a virtual pneumoperitoneum method based on clinical trials for patient-specific laparoscopic surgery simulator

被引:5
|
作者
Oda, Masahiro [1 ]
Qu, Jia Di [1 ]
Nimura, Yukitaka [2 ]
Kitasaka, Takayuki [3 ]
Misawa, Kazunari [4 ]
Mori, Kensaku [1 ,2 ]
机构
[1] Nagoya Univ, Grad Sch Informat Sci, Chikusa Ku, Furo Cho, Nagoya, Aichi 4648603, Japan
[2] Nagoya Univ, Informat & Commun Headquarters, Chikusa Ku, Nagoya, Aichi 4648601, Japan
[3] Aichi Inst Technol, Sch Informat Sci, Toyota, Aichi 4700392, Japan
[4] Aichi Canc Ctr, Chikusa Ku, Nagoya, Aichi 4648681, Japan
基金
日本学术振兴会;
关键词
CT image; laparoscopic surgery; virtual pneumoperitoneum method;
D O I
10.1117/12.911701
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This paper evaluates deformation accuracy of a virtual pneumoperitoneum method by utilizing measurement data of real deformations of patient bodies. Laparoscopic surgery is an option of surgical operations that is less invasive technique as compared with traditional surgical operations. In laparoscopic surgery, the pneumoperitoneum process is performed to create a viewing and working space. Although a virtual pneumoperitoneum method based on 3D CT image deformation has been proposed for patient-specific laparoscopy simulators, quantitative evaluation based on measurements obtained in real surgery has not been performed. In this paper, we evaluate deformation accuracy of the virtual pneumoperitoneum method based on real deformation data of the abdominal wall measured in operating rooms (ORs.) The evaluation results are used to find optimal deformation parameters of the virtual pneumoperitoneum method. We measure landmark positions on the abdominal wall on a 3D CT image taken before performing a pneumoperitoneum process. The landmark positions are defined based on anatomical structure of a patient body. We also measure the landmark positions on a 3D CT image deformed by the virtual pneumoperitoneum method. To measure real deformations of the abdominal wall, we measure the landmark positions on the abdominal wall of a patient before and after the pneumoperitoneum process in the OR. We transform the landmark positions measured in the OR from the tracker coordinate system to the CT coordinate system. A positional error of the virtual pneumoperitoneum method is calculated based on positional differences between the landmark positions on the 3D CT image and the transformed landmark positions. Experimental results based on eight cases of surgeries showed that the minimal positional error was 13.8 mm. The positional error can be decreased from the previous method by calculating optimal deformation parameters of the virtual pneumoperitoneum method from the experimental results.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Accuracy of Segmented Le Fort I Osteotomy with Virtual Planning in Orthognathic Surgery Using Patient-Specific Implants: A Case Series
    Rios, Olina
    Lerhe, Barbara
    Chamorey, Emmanuel
    Savoldelli, Charles
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (19)
  • [22] Evaluation of the accuracy of resected bone thickness based on patient-specific instrumentation during total knee arthroplasty
    Yamamura, Kazumasa
    Inori, Fumiaki
    Konishi, Sadahiko
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (09) : 1583 - 1590
  • [23] Evaluation of the accuracy of resected bone thickness based on patient-specific instrumentation during total knee arthroplasty
    Kazumasa Yamamura
    Fumiaki Inori
    Sadahiko Konishi
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 1583 - 1590
  • [24] Patient-specific Virtual Temporal Bone Simulation Based on Clinical Cone-beam Computed Tomography
    Andersen, Steven Arild Wuyts
    Varadarajan, Varun V.
    Moberly, Aaron C.
    Hittle, Bradley
    Powell, Kimerly A.
    Wiet, Gregory J.
    LARYNGOSCOPE, 2021, 131 (08): : 1855 - 1862
  • [25] A Novel Framework for Visuo-haptic Percutaneous Therapy Simulation Based on Patient-specific Clinical Trials
    Tai, Yonghang
    Wei, Lei
    Zhou, Hailing
    Nahavandi, Saeid
    Shi, Junsheng
    Li, Qiong
    Li, Feiyan
    2017 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2017, : 3362 - 3366
  • [26] Effect of Patient-Specific Coronary Flow Reserve Values on the Accuracy of MRI-Based Virtual Fractional Flow Reserve
    Hair, Jackson
    Timmins, Lucas
    El Sayed, Retta
    Samady, Habib
    Oshinski, John
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [27] Development of a fast, voxel-based, and scanner-specific CT simulator for image quality based virtual clinical trials
    Abadi, Ehsan
    Harrawood, Brian
    Kapadia, Anuj
    Segars, W. Paul
    Samei, Ehsan
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [28] Corrective osteotomies of phalangeal and metacarpal malunions using patient-specific guides: CT-based accuracy evaluation
    Hirsiger, Stefanie
    Miyake, Junichi
    Furnstahl, Philipp
    Nagy, Ladislav
    Schweizer, Andreas
    SWISS MEDICAL WEEKLY, 2015, 145 : 21S - 21S
  • [29] Virtual Spacer Implantation Platform Based on Finite Element Method for Simulation and Planning Patient-Specific Spacer Placement
    Hooshangnejad, H.
    Youssefian, S.
    Ding, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E302 - E303
  • [30] Analytical Validation of Patient-Specific PCR-Based MRD Assessment for Use As a Primary Endpoint in CLL Clinical Trials
    Schilhabel, Anke
    Knecht, Henrik
    Langerak, Anton W.
    van Dongen, Jacques J. M.
    Kneba, Michael
    Ray, Jill
    Punnoose, Elizabeth
    Kim, Doris
    Haberberger, Thomas
    Bernaards, Coen
    Zhu, Yuda
    Lewin-Koh, Sock-Cheng
    Ritgen, Matthias
    BLOOD, 2015, 126 (23)