A Simple and Low-cost Approach to Blood Flow Monitoring Using Speckle Contrast Technique

被引:0
|
作者
Ma, Haiyan [1 ]
Wijshoff, Ralph [2 ]
Mader, Sebastian [1 ]
Veen, Jeroen [3 ]
Van der Mark, Martin [3 ]
Bhattacharya, Nandini [1 ]
Urbach, Paul [1 ]
机构
[1] Delft Univ Technol, Lorentzweg 1, NL-2628 CJ Delft, Netherlands
[2] Eindhoven Univ Technol, NL-5612 AZ Eindhoven, Netherlands
[3] Philips Res Eindhoven, NL-5656 AE Eindhoven, Netherlands
关键词
Laser Speckle Contrast Imaging; Heartbeat Detection; Speckle Velocimetry and Signal to Noise Ratio;
D O I
暂无
中图分类号
O59 [应用物理学];
学科分类号
摘要
A laser speckle contrast imaging (LSI) setup has been designed and used to estimate heartbeat rate and microvascular perfusion non-invasively. LSI measurements were performed on the human index finger and thumb during various finger perfusion conditions, such as before and after gently rubbing of a finger or the healing of a small inflammation of the eponychium on the finger. Heartbeat was retrieved with 0.5 to 10ms exposure time using LASCA (Laser Speckle Contrast Analysis) and dLASCA (dynamic Laser Speckle Contrast Analysis) processing methods. Additionally, a noise analysis model for laser speckle contrast imaging was established to evaluate Signal to Noise Ratio (SNR) in speckle imaging and provide a guideline for camera selection and imaging system design.
引用
收藏
页码:50 / +
页数:2
相关论文
共 50 条
  • [41] A SIMPLE LOW-COST FOOTSWITCH
    LIGGINS, AB
    BOWKER, P
    JOURNAL OF BIOMEDICAL ENGINEERING, 1991, 13 (01): : 87 - 88
  • [42] A SIMPLE, LOW-COST SCANNER
    GODWIN, J
    LASER FOCUS WITH FIBEROPTIC TECHNOLOGY, 1981, 17 (10): : 91 - 93
  • [43] Low-cost, Simple, Diagnostics
    Whitesides, George
    NEW BIOTECHNOLOGY, 2012, 29 : S1 - S1
  • [44] A low-cost simple lens
    Noriaki Horiuchi
    Nature Photonics, 2012, 6 : 418 - 418
  • [45] Automation of a Mattson Bean Cooker: A simple and a low-cost approach
    Sabadoti, Viviane Deroldo
    Miano, Alberto Claudio
    Augusto, Pedro Esteves Duarte
    JOURNAL OF FOOD PROCESSING AND PRESERVATION, 2020, 44 (10)
  • [46] A low-cost mobile platform for whole blood glucose monitoring using colorimetric method
    Zhang, Han
    Chen, Zheyuan
    Dai, Jing
    Zhang, Wei
    Jiang, Yuqian
    Zhou, Anhong
    MICROCHEMICAL JOURNAL, 2021, 162
  • [47] Dynamic speckle imaging with low-cost devices
    Vannoni, Maurizio
    Trivi, Marcelo
    Arizaga, Ricardo
    Rabal, Hector
    Molesini, Giuseppe
    EUROPEAN JOURNAL OF PHYSICS, 2008, 29 (05) : 967 - 975
  • [48] Simple low-cost miniaturization approach for pharmaceutical nanocrystals production
    Romero, Gregori B.
    Keck, Cornelia M.
    Mueller, Rainer H.
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2016, 501 (1-2) : 236 - 244
  • [49] Are the low-cost, blood-glucose monitoring systems reliable?
    Fox, A
    Padilla, V
    Naraine, K
    DIABETOLOGIA, 2004, 47 : A346 - A346
  • [50] Biodegradation or simple adsorption to the support material? Development of a simple, fast and low-cost technique
    R. Maurício
    L. Amaral
    P. Santos Coelho
    F. Santana
    Environmental Monitoring and Assessment, 2013, 185 : 10085 - 10089