A Simple and Low-cost Approach to Blood Flow Monitoring Using Speckle Contrast Technique

被引:0
|
作者
Ma, Haiyan [1 ]
Wijshoff, Ralph [2 ]
Mader, Sebastian [1 ]
Veen, Jeroen [3 ]
Van der Mark, Martin [3 ]
Bhattacharya, Nandini [1 ]
Urbach, Paul [1 ]
机构
[1] Delft Univ Technol, Lorentzweg 1, NL-2628 CJ Delft, Netherlands
[2] Eindhoven Univ Technol, NL-5612 AZ Eindhoven, Netherlands
[3] Philips Res Eindhoven, NL-5656 AE Eindhoven, Netherlands
关键词
Laser Speckle Contrast Imaging; Heartbeat Detection; Speckle Velocimetry and Signal to Noise Ratio;
D O I
暂无
中图分类号
O59 [应用物理学];
学科分类号
摘要
A laser speckle contrast imaging (LSI) setup has been designed and used to estimate heartbeat rate and microvascular perfusion non-invasively. LSI measurements were performed on the human index finger and thumb during various finger perfusion conditions, such as before and after gently rubbing of a finger or the healing of a small inflammation of the eponychium on the finger. Heartbeat was retrieved with 0.5 to 10ms exposure time using LASCA (Laser Speckle Contrast Analysis) and dLASCA (dynamic Laser Speckle Contrast Analysis) processing methods. Additionally, a noise analysis model for laser speckle contrast imaging was established to evaluate Signal to Noise Ratio (SNR) in speckle imaging and provide a guideline for camera selection and imaging system design.
引用
收藏
页码:50 / +
页数:2
相关论文
共 50 条
  • [1] Low-cost laser speckle contrast imaging of blood flow using a webcam
    Richards, Lisa M.
    Kazmi, S. M. Shams
    Davis, Janel L.
    Olin, Katherine E.
    Dunn, Andrew K.
    BIOMEDICAL OPTICS EXPRESS, 2013, 4 (10): : 2269 - 2283
  • [2] Simple and low-cost technique for wavelength division multiplexing channel monitoring
    Iodice, M
    Cocorullo, G
    Della Corte, GF
    Rendina, I
    OPTICAL ENGINEERING, 2000, 39 (06) : 1704 - 1711
  • [3] Non-invasive low-cost deep tissue blood flow measurement with integrated Diffuse Speckle Contrast Spectroscopy
    Biswas, Arindam
    Mohammad, Penaz Parveen Sultana
    Moka, Sadhu
    Takshi, Arash
    Parthasarathy, Ashwin B.
    FRONTIERS IN NEUROERGONOMICS, 2024, 4
  • [4] Simple, safe, low-cost approach offers cell monitoring and balancing
    Brandl, M., 1600, Hearst Business Communications (55):
  • [5] Capillary blood flow monitoring using laser speckle contrast analysis (LASCA)
    Briers, JD
    Richards, G
    He, XW
    JOURNAL OF BIOMEDICAL OPTICS, 1999, 4 (01) : 164 - 175
  • [6] A simple, low-cost and sensitive approach for chemiluminescence detection in flow systems
    Haghighi, Behzad
    Dadashvand, Reza
    ANALYTICAL LETTERS, 2007, 40 (12) : 2425 - 2432
  • [7] Simple low-cost flow line corrosion monitoring at BP Wych Farm
    不详
    INSIGHT, 1998, 40 (11) : 750 - 750
  • [8] Laser speckle technique for monitoring of blood and lymph flow
    Fedosov, IV
    Tuchin, VV
    ALT'03 INTERNATIONAL CONFERENCE ON ADVANCED LASER TECHNOLOGIES: BIOMEDICAL OPTICS, 2003, 5486 : 148 - 153
  • [9] Intravascular speckle contrast optical spectroscopy for blood flow monitoring
    Zhang, Xiaoyu
    Zhao, Tianrui
    OPTICS CONTINUUM, 2025, 4 (04): : 722 - 730
  • [10] A simple and low-cost device for generating hyperpolarized contrast agents using parahydrogen
    Kadlecek, Stephen
    Vahdat, Vahid
    Nakayama, Takeshi
    Ng, Danny
    Emami, Kiarash
    Rizi, Rahim
    NMR IN BIOMEDICINE, 2011, 24 (08) : 933 - 942