A multi-vendor, multi-center study on reproducibility and comparability of fast strain-encoded cardiovascular magnetic resonance imaging

被引:12
|
作者
Erley, Jennifer [1 ]
Zieschang, Victoria [1 ]
Lapinskas, Tomas [1 ,2 ]
Demir, Aylin [3 ]
Wiesemann, Stephanie [3 ]
Haass, Markus [4 ]
Osman, Nael F. [5 ,6 ]
Simonetti, Orlando P. [7 ,8 ]
Liu, Yingmin [9 ]
Patel, Amit R. [10 ]
Mor-Avi, Victor [10 ]
Unal, Orhan [11 ,12 ]
Johnson, Kevin M. [11 ,12 ]
Pieske, Burkert [1 ,13 ,14 ]
Hansmann, Jochen [15 ]
Schulz-Menger, Jeanette [3 ,14 ]
Kelle, Sebastian [1 ,13 ,14 ]
机构
[1] German Heart Inst Berlin, Dept Internal Med Cardiol, Augustenburger Pl 1, D-13353 Berlin, Germany
[2] Lithuanian Univ Hlth Sci, Med Acad, Dept Cardiol, Kaunas, Lithuania
[3] HELIOS Klinikum Berlin Buch, Working Grp Cardiovasc Magnet Resonance, Max Delbrueck Ctr Mol Med, Dept Cardiol & Nephrol,Charite Med Fac,Expt & Cli, Berlin, Germany
[4] Theresienkrankenhaus & St Hedwig Klin, Dept Internal Med Cardiol Angiol, Mannheim, Germany
[5] Johns Hopkins Univ, Sch Med, Dept Radiol & Radiol Sci, Baltimore, MD USA
[6] Myocardial Solut Inc, Morrisville, NC USA
[7] Ohio State Univ, Dept Internal Med, Columbus, OH 43210 USA
[8] Ohio State Univ, Dept Radiol, Columbus, OH 43210 USA
[9] Ohio State Univ, Dorothy M Davis Heart & Lung Res Inst, Wexner Med Ctr, Columbus, OH 43210 USA
[10] Univ Chicago Med, Dept Cardiol, Chicago, IL USA
[11] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[12] Univ Wisconsin, Dept Med Phys, 1530 Med Sci Ctr, Madison, WI 53706 USA
[13] Charite Campus Virchow Klinikum, Dept Internal Med Cardiol, Berlin, Germany
[14] DZHK German Ctr Cardiovasc Res, Partner Site Berlin, Berlin, Germany
[15] Theresienkrankenhaus & St Hedwig Klin, Dept Radiol, Mannheim, Germany
来源
关键词
Strain; fSENC; Agreement; Reproducibility; CMR; Cardiac; Magnetic resonance; SPECKLE-TRACKING ECHOCARDIOGRAPHY; REGIONAL MYOCARDIAL-FUNCTION; GLOBAL LONGITUDINAL STRAIN; EUROPEAN ASSOCIATION; AMERICAN SOCIETY; DEFORMATION; HEART; CONSENSUS;
D O I
10.1007/s10554-020-01775-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Myocardial strain is a convenient parameter to quantify left ventricular (LV) function. Fast strain-encoding (fSENC) enables the acquisition of cardiovascular magnetic resonance images for strain-measurement within a few heartbeats during free-breathing. It is necessary to analyze inter-vendor agreement of techniques to determine strain, such as fSENC, in order to compare existing studies and plan multi-center studies. Therefore, the aim of this study was to investigate inter-vendor agreement and test-retest reproducibility of fSENC for three major MRI-vendors. fSENC-images were acquired three times in the same group of 15 healthy volunteers using 3 Tesla scanners from three different vendors: at the German Heart Institute Berlin, the Charite University Medicine Berlin-Campus Buch and the Theresien-Hospital Mannheim. Volunteers were scanned using the same imaging protocol composed of two fSENC-acquisitions, a 15-min break and another two fSENC-acquisitions. LV global longitudinal and circumferential strain (GLS, GCS) were analyzed by a trained observer (Myostrain 5.0, Myocardial Solutions) and for nine volunteers repeatedly by another observer. Inter-vendor agreement was determined using Bland-Altman analysis. Test-retest reproducibility and intra- and inter-observer reproducibility were analyzed using intraclass correlation coefficient (ICC) and coefficients of variation (CoV). Inter-vendor agreement between all three sites was good for GLS and GCS, with biases of 0.01-1.88%. Test-retest reproducibility of scans before and after the break was high, shown by ICC- and CoV values of 0.63-0.97 and 3-9% for GLS and 0.69-0.82 and 4-7% for GCS, respectively. Intra- and inter-observer reproducibility were excellent for both parameters (ICC of 0.77-0.99, CoV of 2-5%). This trial demonstrates good inter-vendor agreement and test-retest reproducibility of GLS and GCS measurements, acquired at three different scanners from three different vendors using fSENC. The results indicate that it is necessary to account for a possible bias (< 2%) when comparing strain measurements of different scanners. Technical differences between scanners, which impact inter-vendor agreement, should be further analyzed and minimized. DRKS Registration Number: 00013253. Universal Trial Number (UTN): U1111-1207-5874.
引用
收藏
页码:899 / 911
页数:13
相关论文
共 50 条
  • [1] A multi-vendor, multi-center study on reproducibility and comparability of fast strain-encoded cardiovascular magnetic resonance imaging
    Jennifer Erley
    Victoria Zieschang
    Tomas Lapinskas
    Aylin Demir
    Stephanie Wiesemann
    Markus Haass
    Nael F Osman
    Orlando P Simonetti
    Yingmin Liu
    Amit R Patel
    Victor Mor-Avi
    Orhan Unal
    Kevin M Johnson
    Burkert Pieske
    Jochen Hansmann
    Jeanette Schulz-Menger
    Sebastian Kelle
    [J]. The International Journal of Cardiovascular Imaging, 2020, 36 : 899 - 911
  • [2] Traveling Volunteers: A Multi-Vendor, Multi-Center Study on Reproducibility and Comparability of 4D Flow Derived Aortic Hemodynamics in Cardiovascular Magnetic Resonance
    Demir, Aylin
    Wiesemann, Stephanie
    Erley, Jennifer
    Schmitter, Sebastian
    Trauzeddel, Ralf Felix
    Pieske, Burkert
    Hansmann, Jochen
    Kelle, Sebastian
    Schulz-Menger, Jeanette
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (01) : 211 - 222
  • [3] Editorial for "Traveling Volunteers - A Multi-Vendor, Multi-Center Study on Reproducibility and Comparability of 4D Flow Derived Aortic Hemodynamics in Cardiovascular Magnetic Resonance"
    Boban, Marko
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (01) : 223 - 224
  • [4] In-vivo validation of interpolation-based phase offset correction in cardiovascular magnetic resonance flow quantification: a multi-vendor, multi-center study
    Mark B. M. Hofman
    Manouk J. A. Rodenburg
    Karin Markenroth Bloch
    Beat Werner
    Jos J. M. Westenberg
    Emanuela R. Valsangiacomo Buechel
    Robin Nijveldt
    Onno A. Spruijt
    Philip J. Kilner
    Albert C. van Rossum
    Peter D. Gatehouse
    [J]. Journal of Cardiovascular Magnetic Resonance, 21
  • [5] In-vivo validation of interpolation-based phase offset correction in cardiovascular magnetic resonance flow quantification: a multi-vendor, multi-center study
    Hofman, Mark B. M.
    Rodenburg, Manouk J. A.
    Bloch, Karin Markenroth
    Werner, Beat
    Westenberg, Jos J. M.
    Buechel, Emanuela R. Valsangiacomo
    Nijveldt, Robin
    Spruijt, Onno A.
    Kilner, Philip J.
    van Rossum, Albert C.
    Gatehouse, Peter D.
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2019, 21 (1)
  • [6] Strain-encoded (SENC) harmonic phase imaging for fast magnetic resonance elastography
    Osman, NF
    [J]. MEDICAL IMAGING 2001: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 2001, 4321 : 195 - 203
  • [7] Towards standardization of absolute SPECT/CT quantification: a multi-center and multi-vendor phantom study
    Peters, Steffie M. B.
    van der Werf, Niels R.
    Segbers, Marcel
    van Velden, Floris H. P.
    Wierts, Roel
    Blokland, Koos J. A. K.
    Konijnenberg, Mark W.
    Lazarenko, Sergiy, V
    Visser, Eric P.
    Gotthardt, Martin
    [J]. EJNMMI PHYSICS, 2019, 6 (01)
  • [8] Towards standardization of absolute SPECT/CT quantification: a multi-center and multi-vendor phantom study
    Steffie M. B. Peters
    Niels R. van der Werf
    Marcel Segbers
    Floris H. P. van Velden
    Roel Wierts
    Koos (J.) A. K. Blokland
    Mark W. Konijnenberg
    Sergiy V. Lazarenko
    Eric P. Visser
    Martin Gotthardt
    [J]. EJNMMI Physics, 6
  • [9] Lutetium-177 SPECT Quantification: A Multi-Center, Multi-Vendor Comparison
    Viol, S. Meyer
    Peters, S. M. B.
    van der Werf, N. R.
    van Velden, F. H. P.
    de Jong, N.
    Konijnenberg, M.
    Meeuwis, A.
    Gotthardt, M.
    Beijst, C.
    de Jong, H. W. A. M.
    Segbers, M.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S220 - S221
  • [10] Semi-Supervised Segmentation of Multi-vendor and Multi-center Cardiac MRI
    Bolhassani, Mahyar
    Oksuz, Ilkay
    [J]. 29TH IEEE CONFERENCE ON SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS (SIU 2021), 2021,