Removal and Recovery of Cr(VI) from Industrial Plating Wastewater Using Fibrous Anion Exchanger

被引:16
|
作者
Lee, Chang-Gu [1 ]
Park, Jeong-Ann [1 ]
Choi, Jae-Woo [1 ,2 ]
Ko, Seok-Oh [3 ]
Lee, Sang-Hyup [1 ,4 ]
机构
[1] Korea Inst Sci & Technol, Ctr Water Resource Cycle Res, Hwarangno 14 Gil 5, Seoul 136791, South Korea
[2] UST, Dept Energy & Environm Engn, Daejeon 305350, South Korea
[3] Kyung Hee Univ, Dept Civil Engn, 1732 Deogyeong Daero, Yongin 446701, Gyeonggi Do, South Korea
[4] Korea Univ, Grad Sch Convergence Green Technol & Policy, Seoul 136701, South Korea
来源
WATER AIR AND SOIL POLLUTION | 2016年 / 227卷 / 08期
关键词
Fibrous anion exchanger; Cr(VI) recovery; Sorption capacity; Plating wastewater; HEAVY-METAL IONS; HEXAVALENT CHROMIUM; AQUEOUS-SOLUTION; DRINKING-WATER; ADSORPTION; CHROMATE; EQUILIBRIUM; NANOFIBERS; FIBER; ACID;
D O I
10.1007/s11270-016-2992-y
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of this study was to investigate the removal and recovery of hexavalent chromium (Cr(VI)) from industrial plating wastewater using anion exchanger Kanecaron SA fibers in batch systems. The surface morphology and physicochemical properties of the fiber were analyzed by scanning electron microscopy (SEM), energy-dispersive X-ray analysis (EDAX), and Fourier transform infrared spectroscopy (FT-IR). The removal efficiency was affected by the solution pH and showed a plateau formation decreasing on both sides of pH 4. The Cr(VI) uptake on Kanecaron SA fibers was rapidly increased in the first 10 min, and the kinetic data fit well to the Elovich model. Isotherm model analysis demonstrates that the Redlich-Peterson model suitably describes the equilibrium data, and the maximum adsorption capacity (Q(m)) from the Langmuir model was 87.366 mg/g for Cr(VI) in distilled water, 117.977 mg/g for total Cr, and 57.101 mg/g for Cr(VI) in wastewater. Additionally, the Cr(III) contained in the plating wastewater was removed by the Kanecaron SA fibers, while the other heavy metals were not removed. Thermodynamic analysis indicates that Cr(VI) adsorption to Kanecaron SA fibers decreased with increasing temperature from 10 to 50 degrees C, indicating the spontaneous and exothermic nature of the sorption process. The removal efficiency was maintained above 80 % during four regeneration cycles.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Electrocoagulation removal of Cr(VI) from simulated wastewater using response surface methodology
    Bhatti, Manpreet S.
    Reddy, Akepati S.
    Thukral, Ashwani K.
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 172 (2-3) : 839 - 846
  • [42] Surveying the efficiency of Platanus orientalis bark as biosorbent for Ni and Cr(VI) removal from plating wastewater as a real sample
    Akar, Sheida
    Lorestani, Bahareh
    Sobhanardakani, Soheil
    Cheraghi, Mehrdad
    Moradi, Omid
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2019, 191 (06)
  • [43] Surveying the efficiency of Platanus orientalis bark as biosorbent for Ni and Cr(VI) removal from plating wastewater as a real sample
    Sheida Akar
    Bahareh Lorestani
    Soheil Sobhanardakani
    Mehrdad Cheraghi
    Omid Moradi
    Environmental Monitoring and Assessment, 2019, 191
  • [44] Effective Removal of Cr(VI) from Wastewater Using Biochar Derived from Walnut Shell
    Kokab, Tanzeela
    Ashraf, Hafiza Sumbal
    Shakoor, Muhammad Bilal
    Jilani, Asim
    Ahmad, Sajid Rashid
    Majid, Muzaffar
    Ali, Shafaqat
    Farid, Nazar
    Alghamdi, Rana A.
    Al-Quwaie, Diana A. H.
    Hakeem, Khalid Rehman
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (18)
  • [45] Enhanced Adsorptive Removal of Cr (VI) from Plating Industry Wastewater Using CoFe2O4/CTAB Magnetic Nanocomposites
    Tran, Thi Tuong Van
    Nguyen, Duc Linh
    Nguyen, Chi Hieu
    Bui, Tan Nghia
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2024, 41 (04) : 1135 - 1150
  • [46] Enhanced Adsorptive Removal of Cr (VI) from Plating Industry Wastewater Using CoFe2O4/CTAB Magnetic Nanocomposites
    Thi Tuong Van Tran
    Duc Linh Nguyen
    Chi Hieu Nguyen
    Tan Nghia Bui
    Korean Journal of Chemical Engineering, 2024, 41 : 1135 - 1150
  • [47] Chromium(VI) removal from industrial wastewater using hydrogen peroxide assisted electrocoagulation
    Onpeker, Suzan
    Un, U. Tezcan
    DESALINATION AND WATER TREATMENT, 2019, 153 : 402 - 407
  • [48] Characterization of anion exchange fiber for simultaneous removal of Cr(VI) and As(V) in mineral processing wastewater
    Lee, Seung-Chan
    Kang, Jin-Kyu
    Choi, Nag-Choul
    Lee, Chang-Gu
    Kim, Song-Bae
    DESALINATION AND WATER TREATMENT, 2018, 135 : 247 - 257
  • [49] Treatment of Cr(VI) present in plating wastewater using a Cu/Fe galvanic reactor
    Lugo-Lugo, Violeta
    Bernal-Martinez, Lina A.
    Urena-Nunez, Fernando
    Linares-Hernandez, Ivonne
    Tatiana Almazan-Sanchez, Perla
    Vazquez-Santillan, Pedro de J. B.
    FUEL, 2014, 138 : 203 - 214
  • [50] Studies on removal and recovery of Cr(VI) from electroplating wastes
    Ajmal, M
    Rao, RAK
    Siddiqui, BA
    WATER RESEARCH, 1996, 30 (06) : 1478 - 1482