Six-reflection meV-monochromator for synchrotron radiation

被引:99
|
作者
Toellner, T. S. [1 ]
Alatas, A. [1 ]
Said, A. H. [1 ]
机构
[1] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
基金
美国国家科学基金会;
关键词
high resolution; monochromator; X-ray; RAY CRYSTAL COLLIMATORS; MEV ENERGY RESOLUTION; DIFFRACTION CURVES; SCATTERING;
D O I
10.1107/S0909049511017535
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An in-line monochromatization scheme suitable for 10-40 keV synchrotron radiation is presented based on the use of six crystal reflections that achieves meV and sub-meV bandwidths with high efficiency. The theoretical spectral efficiency surpasses all previous multicrystal designs and approaches that of single room-temperature back-reflecting crystals. This article presents the designs of two such devices along with their theoretical and measured performances.
引用
下载
收藏
页码:605 / 611
页数:7
相关论文
共 50 条
  • [41] DIAMOND MONOCHROMATOR-SPLITTER FOR SYNCHROTRON RADIATION WITH IMPROVED REFLECTIVITY.
    Lider, V. V.
    Samoilova, L. V.
    Kovalchuk, M. V.
    Zheludeva, S. I.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 1999, 55 : 526 - 526
  • [42] A SOFT-X-RAY MONOCHROMATOR FOR THE MAX SYNCHROTRON RADIATION FACILITY
    NYHOLM, R
    SVENSSON, S
    NORDGREN, J
    FLODSTROM, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3): : 267 - 271
  • [43] SMALL-SPOT XPS WITH A ZONE PLATE MONOCHROMATOR FOR SYNCHROTRON RADIATION
    LODDERS, F
    GOLDMANN, A
    RUDOLPH, D
    SCHMAHL, G
    BRAUN, W
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1992, 60 (01) : 1 - 12
  • [44] High-quality synthetic diamond for the monochromator of synchrotron radiation beams
    Toda, N
    Sumiya, H
    Satoh, S
    Ishikawa, T
    HIGH HEAT FLUX AND SYNCHROTRON RADIATION BEAMLINES, 1997, 3151 : 329 - 336
  • [45] Technology of the sagittal focusing crystal manufacturing and testing for monochromator in synchrotron radiation
    Zhou, RK
    Fu, X
    Zhou, SH
    Xia, SJ
    ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGY 2000, 2000, 4231 : 515 - 519
  • [46] RECENT EUROPEAN ADVANCES IN MONOCHROMATOR DESIGN FOR USE WITH SYNCHROTRON RADIATION SOURCES
    CODLING, K
    NUCLEAR INSTRUMENTS & METHODS, 1980, 172 (1-2): : 107 - 122
  • [47] IMPROVEMENT OF THE TEMPERATURE DISTRIBUTION ON THE SURFACE OF SI MONOCHROMATOR HEATED BY SYNCHROTRON RADIATION
    HRDY, J
    WOLF, P
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 958 - 959
  • [48] MODIFIED VMR-2 VACUUM MONOCHROMATOR FOR SYNCHROTRON RADIATION EXPERIMENTS
    KOZHEVNIKOV, AV
    TIMCHENKO, NA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1980, 23 (06) : 1466 - 1467
  • [49] X-RAY MONOCHROMATOR SYSTEM FOR USE WITH SYNCHROTRON RADIATION SOURCES
    GOLOVCHENKO, JA
    LEVESQUE, RA
    COWAN, PL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1981, 52 (04): : 509 - 516
  • [50] HIGH FLUX MEDIUM RESOLUTION NORMAL INCIDENCE MONOCHROMATOR FOR SYNCHROTRON RADIATION
    LAVOLLEE, M
    LOPEZDELGADO, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1977, 48 (07): : 816 - 821