Automatic measurement of epidermal thickness from optical coherence tomography images using a new algorithm

被引:25
|
作者
Josse, G. [1 ]
George, J. [1 ]
Black, D. [1 ]
机构
[1] Skin Res Ctr, F-31025 Toulouse 3, France
关键词
optical coherence tomography (OCT); skin; image processing; dermo-epidermal junction (DEJ); HUMAN SKIN; ULTRASOUND; AGE;
D O I
10.1111/j.1600-0846.2011.00499.x
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background/purpose: Optical coherence tomography (OCT) is an imaging system that enables in vivo epidermal thickness (ET) measurement. In order to use OCT in large-scale clinical studies, automatic algorithm detection of the dermo-epidermal junction (DEJ) is needed. This may be difficult due to image noise from optical speckle, which requires specific image treatment procedures to reduce this. In the present work, a description of the position of the DEJ is given, and an algorithm for boundary detection is presented. Methods: Twenty-nine images were taken from the skin of normal healthy subjects, from five different body sites. Seven expert assessors were asked to trace the DEJ for ET measurement on each of the images. The variability between experts was compared with a new image processing method. Results: Between-expert variability was relatively low with a mean standard deviation of 3.4 mm. However, local positioning of the DEJ between experts was often different. The described algorithm performed adequately on all images. ET was automatically measured with a precision of <5 mu m compared with the experts on all sites studied except that of the back. Moreover, the local algorithm positioning was verified. Conclusion: The new image processing method for measuring ET from OCT images significantly reduces calculation time for this parameter, and avoids user intervention. The main advantages of this are that data can be analyzed more rapidly and reproducibly in clinical trials.
引用
收藏
页码:314 / 319
页数:6
相关论文
共 50 条
  • [31] Epidermal layer recognition of optical coherence tomography skin images
    Yang, Chenming
    Li, Zhongliang
    Nan, Nan
    Bu, Yang
    Wang, Xiangzhao
    [J]. FOURTH INTERNATIONAL CONFERENCE ON PHOTONICS AND OPTICAL ENGINEERING, 2021, 11761
  • [32] Ciliary muscle thickness profiles derived from optical coherence tomography images
    Wagner, Sandra
    Zrenner, Eberhart
    Strasser, Torsten
    [J]. BIOMEDICAL OPTICS EXPRESS, 2018, 9 (10): : 5100 - 5114
  • [33] Measurement of retinal thickness from three-dimensional images obtained from C scan images from the optical coherence tomography ophthalmoscope
    Mizota, Atsushi
    Sakuma, Toshiro
    Miyauchi, Osamu
    Honda, Miki
    Tanaka, Minoru
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 35 (03): : 220 - 224
  • [34] Measurement of the remaining dentin thickness using optical coherence tomography for crown preparation
    Fujita, Rie
    Komada, Wataru
    Nozaki, Kosuke
    Miura, Hiroyuki
    [J]. DENTAL MATERIALS JOURNAL, 2014, 33 (03) : 355 - 362
  • [35] The measurement of corneal epithelial thickness in response to hypoxia using optical coherence tomography
    Wang, JH
    Fonn, D
    Simpson, TL
    Jones, L
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 133 (03) : 315 - 319
  • [36] Measurement of epithelial thickness within the oral cavity using optical coherence tomography
    Prestin, Sven
    Rothschild, Sacha I.
    Betz, Christian Stephan
    Kraft, Marcel
    [J]. HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2012, 34 (12): : 1777 - 1781
  • [37] Retinal thickness measurement in myopic eyes using optical coherence tomography.
    Hoh, ST
    Aung, T
    Seah, SKL
    Lim, WK
    Wu, HM
    Lee, L
    Chew, SJ
    Foster, PJ
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S297 - S297
  • [38] Overestimation of subfoveal choroidal thickness by measurement based on horizontally compressed optical coherence tomography images
    Jae Hui Kim
    Se Woong Kang
    Jae Ryung Kim
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2013, 251 : 2837 - 2837
  • [39] Overestimation of subfoveal choroidal thickness by measurement based on horizontally compressed optical coherence tomography images
    Kim, Jae Hui
    Kang, Se Woong
    Ha, Hyo Shin
    Kim, Sang Jin
    Kim, Jae Ryung
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (04) : 1091 - 1096
  • [40] Overestimation of subfoveal choroidal thickness by measurement based on horizontally compressed optical coherence tomography images
    Colin S. H. Tan
    Kai Xiong Cheong
    SriniVas R. Sadda
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2013, 251 : 2835 - 2836