The reliability of the Frankfort Horizontal in roentgenographic cephalometry

被引:3
|
作者
Pancherz, H
Gokbuget, K
机构
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This longitudinal investigation was undertaken to assess the reliability of the Frankfort Horizontal line (FH) when using either anatomical Porion (Po-a) or machine Porion (Po-m) as reference landmarks. Lateral head films (22 pairs) from subjects at the ages of 11 and 14 years were analysed twice. The results revealed that: (i) the registration error of Po-a was larger than of Po-m; (ii) for Po-a the registration error from the 11 year head films was approximately twice as large as from the 14 year head films; (iii) Po-m was, on average, located similar to 9 mm below and 2 mm anterior to Po-a; (iv) during the 3 years of observation, Po-m changed its position downward markedly more than Po-a; (v) due to the diverging location of machine Porion (Po-m) in relation to true Porion (Po-a) and the large change of Po-m with time, the FH was affected considerably. It was concluded that machine Porion was unsuitable for the construction of the FH, A misjudgement of the reference line may result in diagnostic misinterpretations and lead to false conclusions in longitudinal studies, e.g. when the outcome of a particular treatment procedure is evaluated.
引用
收藏
页码:367 / 372
页数:6
相关论文
共 50 条
  • [31] Reliability of Roentgenographic Knee Alignment Measurements in Gonarthrosis
    Huang, Teng-Le
    Wang, Chen-Chie
    Yang, Kai-Chiang
    Wu, Chang-Chin
    JOURNAL OF KNEE SURGERY, 2018, 31 (04) : 302 - 305
  • [32] CONDYLAR GUIDE ANGLE - RELIABILITY DETERMINED USING PROTRUSIVE RECORDS AND CEPHALOMETRY
    CAREY, PD
    SEELIGER, JE
    POTGIETER, PJ
    JOURNAL OF DENTAL RESEARCH, 1976, 55 (03) : 539 - 539
  • [33] Correlation of frankfort horizontal with the sellanasion line angular data in different sagittal skeletal bases
    Maliael, Mathew Thomas
    Subramanian, Aravind Kumar
    Varghese, Remmiya Mary
    BIOINFORMATION, 2020, 16 (12) : 1088 - 1093
  • [34] RELIABILITY OF ROENTGENOGRAPHIC EVALUATION OF VENTRICULAR SEPTAL DEFECTS IN CHILDREN
    SCHWARZ, ED
    DORST, JP
    KUHN, JP
    ROWE, RD
    VARGHESE, PJ
    JOHNS HOPKINS MEDICAL JOURNAL, 1970, 127 (03): : 164 - &
  • [35] Influence of different setups of the Frankfort horizontal plane on 3-dimensional cephalometric measurements
    Goncalves dos Santos, Rodrigo Mologni
    De Martino, Jose Mario
    Haiter Neto, Francisco
    Passeri, Luis Augusto
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2017, 152 (02) : 242 - 249
  • [36] Anterior cranial base and Frankfort planes variability v/s true horizontal.
    Hernandez, R
    Marin, P
    Palacios, S
    Ayala, J
    JOURNAL OF DENTAL RESEARCH, 1998, 77 (05) : 1195 - 1195
  • [37] Frankfort horizontal plane is an appropriate three-dimensinal reference in the evaluation of clinical and skeletal cant
    Oh, Suseok
    Ahn, Jaemyung
    Nam, Ki-Uk
    Paeng, Jun-Young
    Hong, Jongrak
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2013, 39 (02) : 71 - 76
  • [38] Automated Cephalometry: System Performance Reliability Using Landmark-Dependent Criteria
    Tanikawa, Chihiro
    Yagi, Masakazu
    Takada, Kenji
    ANGLE ORTHODONTIST, 2009, 79 (06) : 1037 - 1046
  • [39] Landmarks of the Frankfort horizontal plane: Reliability in a three-dimensional Cartesian coordinate system; [Referenzpunkte der Frankfurter Horizontalen: Reliabilität in einem dreidimensionalen kartesischen Koordinatensystem]
    Hofmann E.
    Fimmers R.
    Schmid M.
    Hirschfelder U.
    Detterbeck A.
    Hertrich K.
    Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 2016, 77 (5): : 373 - 383
  • [40] Confusion of the Standardization in Craniofacial Soft Tissue Measurements: Frankfort Horizontal Plane or Natural Head Position?
    Bahsi, Ilhan
    Orhan, Mustafa
    Kervancioglu, Piraye
    JOURNAL OF CRANIOFACIAL SURGERY, 2021, 32 (08) : 2578 - 2579