High pressure effects in high-field asymmetric waveform ion mobility spectrometry

被引:3
|
作者
Wang, Yonghuan [1 ]
Wang, Xiaozhi [1 ]
Li, Lingfen [2 ]
Chen, Chilai [3 ]
Xu, Tianbai [1 ]
Wang, Tao [1 ]
Luo, Jikui [1 ]
机构
[1] Zhejiang Univ, Dept Informat Sci & Elect Engn, Hangzhou 310027, Peoples R China
[2] Zhejiang Univ, Suzhou Ind Technol Res Inst, Suzhou 215163, Peoples R China
[3] Chinese Acad Sci, Inst Intelligent Machines, Hefei, Anhui, Peoples R China
关键词
FAIMS; OPERATION; ANALYZERS; PRODUCTS;
D O I
10.1002/rcm.7663
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RationaleHigh-Field Asymmetric Waveform Ion Mobility Spectrometry (FAIMS) is an analytical technique based on the principle of non-linear electric field dependence of coefficient of mobility of ions for separation that was originally conceived in the Soviet Union in the early 1980s. Being well developed over the past decades, FAIMS has become an efficient method for the separation and characterization of gas-phase ions at ambient pressure, often in air, to detect trace amounts of chemical species including explosives, toxic chemicals, chemical warfare agents and other compounds. However the resolution of FAIMS and ion separation capability need to be improved for more applications of the technique. MethodsThe effects of above-ambient pressure varying from 1 to 3atm on peak position, resolving power, peak width, and peak intensity are investigated theoretically and experimentally using micro-fabricated planar FAIMS in purified air. ResultsPeak positions, varying with pressure in a way as a function of dispersion voltage, could be simplified by expressing both compensation and dispersion fields in Townsend units for E/N, the ratio of electric field intensity (E) to the gas number density (N). ConclusionsIt is demonstrated that ion Townsend-scale peak positions remain unchanged for a range of pressures investigated, implying that the higher the pressure is, stronger compensation and separation fields are needed within limits of air breakdown field. Increase in pressure is found to separate ions that could not be distinguished in ambient pressure, which could be interpreted as the differentials of ions' peak compensation voltage expanded wider than the dilation of peak widths leading to resolving power enhancement with pressure. Increase in pressure can also result in an increase in peak intensity.
引用
收藏
页码:1914 / 1922
页数:9
相关论文
共 50 条
  • [41] High-Field Asymmetric Waveform Ion Mobility Spectrometry Interface Enhances Parallel Reaction Monitoring on an Orbitrap Mass Spectrometer
    Deng, Weixian
    Sha, Jihui
    Xue, Fanglei
    Jami-Alahmadi, Yasaman
    Plath, Kathrin
    Wohlschlegel, James
    ANALYTICAL CHEMISTRY, 2022, 94 (46) : 15939 - 15947
  • [42] Large-Scale Analysis of Peptide Sequence Variants: The Case for High-Field Asymmetric Waveform Ion Mobility Spectrometry
    Creese, Andrew J.
    Smart, Jade
    Cooper, Helen J.
    ANALYTICAL CHEMISTRY, 2013, 85 (10) : 4836 - 4843
  • [43] Predicting Compensation Voltage for Singly-charged Ions in High-Field Asymmetric Waveform Ion Mobility Spectrometry (FAIMS)
    Aksenov, Alexander A.
    Kapron, James
    Davis, Cristina E.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2012, 23 (10) : 1794 - 1798
  • [44] Comparison of high-field asymmetric waveform ion mobility spectrometry with GC methods in analysis of haloacetic acids in drinking water
    Gabryelski, W
    Wu, FW
    Froese, KL
    ANALYTICAL CHEMISTRY, 2003, 75 (10) : 2478 - 2486
  • [45] High-field asymmetric waveform ion mobility spectrometry for xylene isomer separation assisted by helium-chemical modifiers
    Du, Xiaoxia
    Wang, Yifei
    Zeng, Hongda
    Zeng, Hao
    Chen, Zhencheng
    Li, Hua
    ANALYTICAL METHODS, 2022, 14 (45) : 4649 - 4658
  • [46] Gas modifier assisted re-circulation mode high-field asymmetric waveform ion mobility spectrometry (FAIMS)
    Ruan, Zhiming
    Chen, Chilai
    Chen, Ran
    Liu, Youjiang
    Wang, Xiaozhi
    Li, Shan
    Yu, Jianwen
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2017, 414 : 8 - 12
  • [47] Global Phosphoproteome Analysis Using High-Field Asymmetric Waveform Ion Mobility Spectrometry on a Hybrid Orbitrap Mass Spectrometer
    Muehlbauer, Laura K.
    Hebert, Alexander S.
    Westphall, Michael S.
    Shishkova, Evgenia
    Coon, Joshua J.
    ANALYTICAL CHEMISTRY, 2020, 92 (24) : 15959 - 15967
  • [48] Analysis of paralytic shellfish toxins using high-field asymmetric waveform ion mobility spectrometry with liquid chromatography-mass spectrometry
    Daniel G. Beach
    Jeremy E. Melanson
    Randy W. Purves
    Analytical and Bioanalytical Chemistry, 2015, 407 : 2473 - 2484
  • [49] ANYL 376-Separation and characterization of explosive compounds using high-field asymmetric waveform ion mobility spectrometry/mass spectrometry
    Wu, Ching-Hong Alex
    Yost, Richard A.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2008, 236
  • [50] Removal of metabolite interference during liquid chromatography/tandem mass spectrometry using high-field asymmetric waveform ion mobility spectrometry
    Kapron, JT
    Jemal, M
    Duncan, G
    Kolakowski, B
    Purves, R
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (14) : 1979 - 1983