40-MHz high-frequency vector Doppler imaging for superficial venous valve flow estimation

被引:10
|
作者
Huang, Hsin [1 ]
Chen, Pei-Yu [1 ]
Huang, Chih-Chung [1 ,2 ]
机构
[1] Natl Cheng Kung Univ, Dept Biomed Engn, Tainan, Taiwan
[2] Natl Cheng Kung Univ, Med Device Innovat Ctr, Tainan, Taiwan
关键词
blood flow measurement; high-frequency ultrasound; ultrafast ultrasound imaging; vector Doppler imaging; venous valve; UIP CONSENSUS DOCUMENT; LOWER-LIMBS; ULTRASOUND; DISEASE; BLOOD; PARAMETERS; SYSTEM; VEINS; ANGLE;
D O I
10.1002/mp.14362
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Doppler ultrasound imaging has been used widely for diagnosing vascular diseases. Recently, vector Doppler imaging (VDI) has been proposed for visualizing the blood flow in all directions to yield more detailed information for estimating flow conditions. Increasing the resolution of VDI is important for the structural mapping of superficial vessels with microstructure. However, VDI that operates under a high-frequency ultrasound (HFUS; >30 MHz) is rare. In this study, a 40-MHz high-frequency VDI (HFVDI) based on ultrafast ultrasound imaging was developed to obtain the vector information of blood flow around the superficial venous valve. Methods The use of HFUS imaging system causes an overload of data acquisition easily. In order to provide sufficient recording time, the frame rate should be reduced. Because the aliasing problem worsens due to a low frame rate when operating Doppler imaging, phase-unwrapping processing methods based on spatial and temporal continuities were applied. Flow phantom experiments were performed to validate the accuracy.In vivoexperiments were performed on the valve of superficial veins of healthy volunteers. Results The experimental results from the phantom study indicated that the error of velocity estimation was <10% in most cases. Dynamic changes of valve movements and flow conditions (including velocity profiles and vector) were observed. Because of the high resolution of HFVDI, the jet and vortex phenomena were observed between the leaflets and in the sinus pocket, respectively. Conclusions Flow velocities ranging from 2 to 15 mm/s were measured at different locations around the venous valve during the opening and closing phases. All the results indicated that HFVDI has the potential to be a useful tool for vessel duplex scanning.
引用
收藏
页码:4020 / 4031
页数:12
相关论文
共 50 条
  • [1] Blood flow evaluation in high-frequency, 40 MHz imaging: A comparative study of four vector velocity estimation methods
    Marion, Adrien
    Aoudi, Walid
    Basarab, Adrian
    Delachartre, Philippe
    Vray, Didier
    ULTRASONICS, 2010, 50 (07) : 683 - 690
  • [2] 40 MHz high-frequency ultrafast ultrasound imaging
    Huang, Chih-Chung
    Chen, Pei-Yu
    Peng, Po-Hsun
    Lee, Po-Yang
    MEDICAL PHYSICS, 2017, 44 (06) : 2185 - 2195
  • [3] Increasing the Maximum Detectable Flow Velocity in High-Frequency Ultrasound Vector Doppler Imaging
    Yang, Chi-Hung
    Huang, Hsin
    Lee, Po-Yang
    Chuang, Yi-Hsiang
    Chang, Wei-Ting
    Huang, Chih-Chung
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2024, 71 (11) : 3181 - 3191
  • [4] ULTRASOUND IMAGING AND COLOR FLOW DOPPLER OF THE SUPERFICIAL VENOUS SYSTEM
    RAYMONDMARTIMBEAU, P
    PHLEBOLOGY 89: PROCEEDINGS OF THE 10TH WORLD CONGRESS OF THE UNION-INTERNATIONALE-DE-PHLEBOLOGIE, 1989, : 347 - 347
  • [5] High-Resolution Tissue Doppler and Strain Imaging for Adult Zebrafish Myocardial Tissue Through Ultrafast High-Frequency Ultrasound Vector Doppler Estimation
    Huang, Hsin
    Machikhin, Alexander
    Chen, De-Quan
    Huang, Chih-Chung
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (08) : 1006 - 1018
  • [6] Evaluation of Hand Tendon Movement by Using High-Frequency Ultrasound Vector Doppler Imaging
    Wang, Min-Yuan
    Yang, Tai-Hua
    Huang, Hsin
    Hsu, Hsiu-Yun
    Kuo, Li-Chieh
    Su, Fong-Chin
    Huang, Chih-Chung
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (10) : 2945 - 2952
  • [7] High frequency 40-MHz ultrasound - A possible noninvasive method for the assessment of the boundary of basal cell carcinomas
    Gupta, AK
    Turnbull, DH
    Foster, FS
    Harasiewicz, KA
    Shum, DT
    Prussick, R
    Watteel, GN
    Hurst, LN
    Sauder, DN
    DERMATOLOGIC SURGERY, 1996, 22 (02) : 131 - 136
  • [8] High-Frequency Nonlinear Doppler Contrast-Enhanced Ultrasound Imaging of Blood Flow
    Bruce, Matthew
    Hannah, Alex
    Hammond, Ryan
    Khaing, Zin Z.
    Tremblay-Darveau, Charles
    Burns, Peter N.
    Hofstetter, Christoph P.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (09) : 1776 - 1784
  • [9] Beyond 30 MHz - Applications of high-frequency ultrasound imaging
    Lockwood, GR
    Turnbull, DH
    Christopher, DA
    Foster, FS
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1996, 15 (06): : 60 - 71
  • [10] Calibration of high-frequency hydrophone up to 40 MHz by heterodyne interferometer
    Yang, Ping
    Xing, Guangzhen
    He, Longbiao
    ULTRASONICS, 2014, 54 (01) : 402 - 407