Dosimetric comparison of three different external beam whole breast irradiation techniques

被引:19
|
作者
Gursel, Bilge [1 ]
Meydan, Deniz [1 ]
Ozbek, Nilgun [1 ]
Ofluoglu, Tenzile [1 ]
机构
[1] Ondokuz Mayis Univ, Dept Radiat Oncol, Sch Med, TR-55139 Atakum, Samsun, Turkey
关键词
breast cancer; conformal radiotherapy; dosimetry; field-in-field radiotherapy; INTENSITY-MODULATED RADIOTHERAPY; 3-DIMENSIONAL CONFORMAL RADIOTHERAPY; IN-FIELD TECHNIQUE; 20-YEAR FOLLOW-UP; RANDOMIZED-TRIAL; CANCER; IMRT; LUNG; MASTECTOMY;
D O I
10.1007/s12325-011-0078-1
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Introduction: The purpose of this study was to compare the dosimetries of three different external beam whole breast radiotherapy techniques: two-dimensional RT (2D-RT), three-dimensional conformal RT (3D-CRT), and field-in-field intensity-modulated RT (FiF-IMRT). In addition, we aimed to evaluate the patients who needed more or less complex treatment modalities. Methods: Thirty patients were included in the study. All the patients had earlystage breast cancer and conserving surgery had been performed. Plans that employed the three techniques were generated for each patient. Dosimetric comparisons were conducted, and correlations with patient characteristics and dosimetric outcomes were analyzed. Results: The 2D-RT technique was found to be suboptimal for treating the intact breast. Its dose homogeneity index (DHI) was 20.68. The authors were unable to define a patient characteristic in which 2D-RT dosimetry would perform better. FiF-IMRT was found to be the superior technique with a better homogeneity in the breast (DHI=9.35 and P=0.000002 when compared to 3D-CRT). When compared according to patient characteristics, again the FiF-IMRT planning is the best for all subgroups, but the DHI gets worse by increased breast volume and separation. While FiF-IMRT achieves better DHI in the breast, it has little effect on heart and lung doses. But the normal tissues' volume (cc) that gets the 100% of the prescribed dose (V100) was lowered because of the treatment without wedges and scatter and with less monitor unit. Conclusions: 2D-RT could not be performed safely on the intact breast in any of the subgroups. FiF-IMRT is a superior technique for breast dosimetry, and normal tissue. For patients with large breast size or separation, further intensive techniques must be investigated.
引用
收藏
页码:1114 / 1125
页数:12
相关论文
共 50 条
  • [31] Hybrid volumetric modulated arc therapy for whole breast irradiation: a dosimetric comparison of different arc designs
    Ramasubramanian, Velayudham
    Balaji, Karunakaran
    Subramanian, Sitaraman Balaji
    Sathiya, Krishnamoorthi
    Thirunavukarasu, Moorthi
    Radha, Chandrasekaran Anu
    RADIOLOGIA MEDICA, 2019, 124 (06): : 546 - 554
  • [32] A study of dosimetric differences between four techniques of whole breast tangential irradiation
    Ng, Y.
    Swaminathan, I.
    Lee, J.
    Yap, J.
    Salleh, P.
    Chua, L.
    Wong, F. Y.
    EUROPEAN JOURNAL OF CANCER, 2014, 50 : S215 - S216
  • [33] A comparison of dosimetric variance for external-beam partial breast irradiation using three-dimensional and four-dimensional computed tomography
    Guo, Bing
    Li, Jian-Bin
    Wang, Wei
    Xu, Min
    Li, Yan-Kang
    Liu, Tong-Hai
    ONCOTARGETS AND THERAPY, 2016, 9 : 1857 - 1863
  • [34] A study of dosimetric differences between four techniques of whole breast tangential irradiation
    Ng, Y. Y.
    Swaminathan, I.
    Lee, J.
    Yap, J.
    Salleh, P.
    Chua, L.
    Wong, F. Y.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S309 - S310
  • [35] Dosimetric Comparison of Whole-Breast Irradiation Techniques: Supine Versus Prone Positions Using Helical Tomotherapy
    Wang, Y.
    Chang, S.
    Chen, W.
    MEDICAL PHYSICS, 2009, 36 (06) : 2542 - +
  • [36] DOES THREE-DIMENSIONAL EXTERNAL BEAM PARTIAL BREAST IRRADIATION SPARE LUNG TISSUE COMPARED WITH STANDARD WHOLE BREAST IRRADIATION?
    Jain, Anudh K.
    Vallow, Laura A.
    Gale, Ashley A.
    Buskirk, Steven J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (01): : 82 - 88
  • [37] Dosimetric comparison of radiation techniques in the irradiation of the supraclavicular fossa in breast cancer
    Ahmed, M.
    King, D.
    Barron, S.
    Quigley, M.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S64 - S65
  • [38] A DOSIMETRIC COMPARISON OF CONVENTIONAL EXTERNAL BEAM RADIATION THERAPY TECHNIQUES FOR PITUITARY ADENOMA
    Kelly, G.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S254 - S254
  • [39] A DOSIMETRIC COMPARISON OF CONVENTIONAL EXTERNAL BEAM RADIATION THERAPY TECHNIQUES FOR PITUITARY ADENOMA
    Kelly, G.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S254 - S254
  • [40] Dosimetric comparison of left sided whole breast irradiation with Tangential wedge beam,electron boosted Tangential wedged beam and asymmetric technique
    Fadavi, Pedram
    Ahmadi, Helaleh Khoshbakht
    Diba, Ali Asghar Yousefi
    Jafari, Fatemeh
    Alamolhoda, Mahboobeh
    JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE, 2020, 9 (12) : 6135 - 6139