Dosimetric comparison of three different external beam whole breast irradiation techniques

被引:19
|
作者
Gursel, Bilge [1 ]
Meydan, Deniz [1 ]
Ozbek, Nilgun [1 ]
Ofluoglu, Tenzile [1 ]
机构
[1] Ondokuz Mayis Univ, Dept Radiat Oncol, Sch Med, TR-55139 Atakum, Samsun, Turkey
关键词
breast cancer; conformal radiotherapy; dosimetry; field-in-field radiotherapy; INTENSITY-MODULATED RADIOTHERAPY; 3-DIMENSIONAL CONFORMAL RADIOTHERAPY; IN-FIELD TECHNIQUE; 20-YEAR FOLLOW-UP; RANDOMIZED-TRIAL; CANCER; IMRT; LUNG; MASTECTOMY;
D O I
10.1007/s12325-011-0078-1
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Introduction: The purpose of this study was to compare the dosimetries of three different external beam whole breast radiotherapy techniques: two-dimensional RT (2D-RT), three-dimensional conformal RT (3D-CRT), and field-in-field intensity-modulated RT (FiF-IMRT). In addition, we aimed to evaluate the patients who needed more or less complex treatment modalities. Methods: Thirty patients were included in the study. All the patients had earlystage breast cancer and conserving surgery had been performed. Plans that employed the three techniques were generated for each patient. Dosimetric comparisons were conducted, and correlations with patient characteristics and dosimetric outcomes were analyzed. Results: The 2D-RT technique was found to be suboptimal for treating the intact breast. Its dose homogeneity index (DHI) was 20.68. The authors were unable to define a patient characteristic in which 2D-RT dosimetry would perform better. FiF-IMRT was found to be the superior technique with a better homogeneity in the breast (DHI=9.35 and P=0.000002 when compared to 3D-CRT). When compared according to patient characteristics, again the FiF-IMRT planning is the best for all subgroups, but the DHI gets worse by increased breast volume and separation. While FiF-IMRT achieves better DHI in the breast, it has little effect on heart and lung doses. But the normal tissues' volume (cc) that gets the 100% of the prescribed dose (V100) was lowered because of the treatment without wedges and scatter and with less monitor unit. Conclusions: 2D-RT could not be performed safely on the intact breast in any of the subgroups. FiF-IMRT is a superior technique for breast dosimetry, and normal tissue. For patients with large breast size or separation, further intensive techniques must be investigated.
引用
收藏
页码:1114 / 1125
页数:12
相关论文
共 50 条
  • [1] Dosimetric comparison of three different external beam whole breast irradiation techniques
    Bilge Gursel
    Deniz Meydan
    Nilgun Ozbek
    Tenzile Ofluoglu
    [J]. Advances in Therapy, 2011, 28 : 1114 - 1125
  • [2] Dosimetric comparison of two different three-dimensional conformal external beam accelerated partial breast irradiation techniques
    Kozak, Kevin R.
    Doppke, Karen P.
    Katz, Angela
    Taghian, Alphonse G.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (02): : 340 - 346
  • [3] DOSIMETRIC COMPARISON OF THREE-DIMENSIONAL CONFORMAL RADIOTHERAPY AND INTERSTITIAL BRACHYTHERAPY FOR PARTIAL BREAST IRRADIATION, AND WHOLE BREAST EXTERNAL BEAM IRRADIATION
    Major, T.
    Frohlich, G.
    Janvary, L.
    Polgar, C.
    Fodor, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S443 - S444
  • [4] External beam accelerated partial breast irradiation: dosimetric assessment of conformal and three different intensity modulated techniques
    Stelczer, Gabor
    Major, Tibor
    Meszaros, Norbert
    Polgar, Csaba
    Pesznyak, Csilla
    [J]. RADIOLOGY AND ONCOLOGY, 2019, 53 (01) : 123 - 130
  • [5] Dosimetric comparison of partial and whole breast external beam irradiation in the treatment of early stage breast cancer
    Kim, Yongbok
    Parda, David S.
    Trombetta, Mark G.
    Colonias, Athanasios
    Werts, E. Day
    Miller, Linda
    Miften, Moyed
    [J]. MEDICAL PHYSICS, 2007, 34 (12) : 4640 - 4648
  • [6] Dosimetric comparison of proton and photon three-dimensional, conformal, external beam accelerated partial breast irradiation techniques
    Kozak, Kevin R.
    Katz, Angela
    Adams, Judith
    Crowley, Elizabeth M.
    Nyamwanda, Jacqueline A.
    Feng, Jennifer K.
    Doppke, Karen P.
    DeLaney, Thomas F.
    Taghian, Alphonse G.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (05): : 1572 - 1578
  • [7] Dosimetric comparison of four different external beams for breast irradiation
    Yoon Hee Lee
    Weon Kuu Chung
    Dong Wook Kim
    Oh Young Kwon
    [J]. Journal of the Korean Physical Society, 2017, 70 : 300 - 307
  • [8] Dosimetric Comparison of Four Different External Beams for Breast Irradiation
    Lee, Yoon Hee
    Chung, Weon Kuu
    Kim, Dong Wook
    Kwon, Oh Young
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2017, 70 (03) : 300 - 307
  • [9] External beam radiotherapy and brachytherapy for partial breast irradiation: dosimetric comparison
    Irina, A.
    Sergey, N.
    Zhanna, B.
    Julia, M.
    Sergey, K.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 158 : S131 - S131
  • [10] A dosimetric comparison of two external beam conformal treatment techniques for the delivery of accelerated partial breast irradiation (APBI)
    Doppke, KP
    Kozak, KR
    Katz, A
    Taghian, AG
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S177 - S178