Vertical silica nanochannels supported by nanocarbon composite for simultaneous detection of serotonin and melatonin in biological fluids

被引:58
|
作者
Zhou, Huaxu [1 ]
Ma, Xinyu [1 ]
Sailjoi, Ajabkhan [1 ]
Zou, Yanqi [1 ]
Lin, Xingyu [2 ]
Yan, Fei [1 ]
Su, Bin [3 ]
Liu, Jiyang [1 ]
机构
[1] Zhejiang Sci Tech Univ, Dept Chem, Xiasha Higher Educ Zone, 928 Second Ave, Hangzhou 310018, Peoples R China
[2] Zhejiang Univ, Coll Biosyst Engn & Food Sci, Hangzhou 310058, Peoples R China
[3] Zhejiang Univ, Inst Analyt Chem, Dept Chem, Hangzhou 310058, Peoples R China
基金
中国国家自然科学基金;
关键词
Vertically-oriented mesoporous silica films; Reduced graphene oxide; Carbon nanotube; Nanocarbon composite; Serotonin; Melatonin; REDUCED GRAPHENE OXIDE; DIRECT ELECTROCHEMICAL ANALYSIS; MULTIWALLED CARBON NANOTUBES; MODIFIED ELECTRODE; NANOPARTICLES; MESOCHANNELS; MEMBRANES; FILM;
D O I
10.1016/j.snb.2021.131101
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Herein we report the simultaneous determination of serotonin (5-HT) and melatonin (MT) by using highly or-dered and vertically-oriented mesoporous silica-nanochannel films (VMSF) on highly electrochemically reduced graphene oxide-carbon nanotubes (HErGO-CNT) composite substrate. Such VMSF/HErGO-CNT with compact 2D-2D layered structure is fabricated on indium tin oxide (ITO) electrodes via a two-step electrochemical pro-cess, namely the electrodeposition of ErGO-CNT film onto the ITO surface by cyclic voltammetry and subse-quently growth of VMSF on the ErGO-CNT/ITO surface by electrochemically assisted self-assembly method, during which graphene oxide (GO) is subjected to the two-time electrochemical reduction to form HErGO. The CNT encased in the GO sheets served as electronic conducting wires, which not only can promote the electro-chemical reduction of GO but also contribute to a certain degree of hydrophobicity, facilitating the controllable electrodeposition of ErGO-CNT composites on ITO under its safe use potential window. In addition, doping CNT is able to enlarge the layer gap between graphene sheets and thus improves the electroactive area and mass transfer of the nanocarbon composite substrate. Furthermore, the underlying HErGO-CNT acts as an efficient electroactive layer and the outer VMSF possesses electrostatic preconcentration and anti-fouling functions, synergistically realizing the direct electrochemical analysis of 5-HT and MT in two complex biological fluids (human whole blood and artificial cerebrospinal fluid).
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Determination of tryptophan metabolism from biological tissues and fluids using high performance liquid chromatography with simultaneous dual electrochemical detection
    Brooks, Emily L.
    Mutengwa, Vongai S.
    Abdalla, Aya
    Yeoman, Mark S.
    Patel, Bhavik Anil
    ANALYST, 2019, 144 (20) : 6011 - 6018
  • [22] SIMULTANEOUS DETERMINATION OF PERHEXILINE AND ITS MONOHYDROXY METABOLITES IN BIOLOGICAL-FLUIDS BY GAS-CHROMATOGRAPHY ELECTRON-CAPTURE DETECTION
    COOPER, RG
    HARPER, G
    PRICE, AH
    EVANS, DAP
    LOCKHART, D
    JOURNAL OF CHROMATOGRAPHY, 1986, 381 (02): : 305 - 314
  • [23] SIMULTANEOUS DETERMINATION OF KETANSERIN AND KETANSERINOL IN BIOLOGICAL-FLUIDS USING ION-PAIR LIQUID-CHROMATOGRAPHY AND FLUOROMETRIC DETECTION
    KUROWSKI, M
    JOURNAL OF CHROMATOGRAPHY, 1985, 341 (01): : 208 - 212
  • [24] Simultaneous quantitative determination of the major phase I and II metabolites of ibuprofen in biological fluids by high-performance liquid chromatography on dynamically modified silica
    Kepp, DR
    Sidelmann, UG
    Tjornelund, J
    Hansen, SH
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1997, 696 (02): : 235 - 241
  • [25] Point-of-care vertical flow immunoassay system for ultra-sensitive multiplex biothreat-agent detection in biological fluids
    Devadhasan, Jasmine Pramila
    Summers, Alexander Jarrett
    Gu, Jian
    Smith, Stanley
    Thomas, Baiju
    Fattahi, Ali
    Helton, James
    Pandit, Sujata G.
    Gates-Hollingsworth, Marcellene
    Hau, Derrick
    Pflughoeft, Kathryn J.
    Montgomery, Douglas C.
    Atta, Supriya
    Vo-Dinh, Tuan
    AuCoin, David
    Zenhausern, Frederic
    BIOSENSORS & BIOELECTRONICS, 2023, 219
  • [26] DETERMINATION OF PROPAFENONE IN BIOLOGICAL-FLUIDS BY FUSED-SILICA CAPILLARY GAS-CHROMATOGRAPHY USING ELECTRON-CAPTURE DETECTION
    CHAN, GLY
    AXELSON, JE
    ABBOTT, FS
    KERR, CR
    MCERLANE, KM
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 417 (02): : 295 - 308
  • [27] Simultaneous determination of sulfamethoxazole and trimethoprim in biological fluids for high-throughput analysis:: Comparison of HPLC with ultraviolet and tandem mass spectrometric detection
    Bedor, D. C. G.
    Goncalves, T. M.
    Ferreiraa, M. L. L.
    de Sousaa, C. E. M.
    Menezes, A. L.
    Oliveira, E. J.
    de Santana, D. P.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 863 (01): : 46 - 54
  • [28] DETERMINATION OF PROGABIDE AND ITS ACID METABOLITE IN BIOLOGICAL-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON SILICA COLUMN WITH ULTRAVIOLET DETECTION
    ASCALONE, V
    CATALANI, P
    DALBO, L
    JOURNAL OF CHROMATOGRAPHY, 1985, 344 (NOV): : 231 - 239
  • [29] Hierarchically structured CuFe2O4 ND@RGO composite for the detection of oxidative stress biomarker in biological fluids
    Chen, Shen-Ming
    Umamaheswari, Rajaji
    Mani, Govindasamy
    Chen, Tse-Wei
    Ali, M. Ajmal
    Fahad, Al-Hemaid M. A.
    Elshikh, M. S.
    Abul Farah, M.
    INORGANIC CHEMISTRY FRONTIERS, 2018, 5 (04): : 944 - 950
  • [30] Simultaneous determination of piroxicam and norfloxacin in biological fluids by high-performance liquid chromatography with fluorescence detection at zero-order emission mode
    Gamal, Mohammed
    Ali, Hazim M.
    Fraihat, Safwan M.
    Elnasr, T. A. Seaf
    LUMINESCENCE, 2019, 34 (06) : 644 - 650