Flow rate estimation in large depth-of-field micro-PIV

被引:44
|
作者
Kloosterman, A. [1 ]
Poelma, C. [1 ]
Westerweel, J. [1 ]
机构
[1] Delft Univ Technol, Proc & Energy Dept, Fac Mech Maritime & Mat Engn, Lab Aero & Hydrodynam, NL-2628 CD Delft, Netherlands
关键词
PARTICLE IMAGE VELOCIMETRY; BLOOD-FLOW; HEART;
D O I
10.1007/s00348-010-1015-9
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In micro-Particle Image Velocimetry, the requirement of a large field-of-view often results in a large depth-of-correlation, i.e. large depth of the measurement volume. When the velocity varies substantially over the depth-of-correlation, special attention should be paid to a correct interpretation of the measured velocities. When a specialized microscope is needed to meet the requirements of a setup, the resulting more complex optical arrangements can have additional effects on the measurement results. In order to determine flow parameters such as the flow rate, it is sufficient to have a robust estimate of the maximum velocity when the flow is Poiseuille flow. In this paper, an interpretation of the results from particle image velocimetry measurements with low magnification in a round capillary is given for two types of microscopes: a conventional and a specialized microscope. The measured velocity appears to be lower than the maximum velocity, yet is still above the average velocity. The interpretation of the measured velocity differs for the two types of microscopes. The under-estimation of the maximum velocity obtained from the conventional microscope remains small (within 6%) for low-magnification measurements, while the under-estimation of the maximum velocity obtained from the specialized microscope increases up to 25% for a large depth-of-correlation. The images of the in- and out-of-focus particles turn out to play a crucial role in this difference between the two microscopes. Validation of the optical properties of a microscope is important, especially for specialized microscopes where particle images deviate substantially from the existing theory, and this theory is also used to derive the analytical expression for the depth-of-correlation. A procedure is recommended to obtain a correct interpretation of the measured velocity. This procedure is generally applicable, but mainly of importance for specialized microscopes.
引用
收藏
页码:1587 / 1599
页数:13
相关论文
共 50 条
  • [21] Velocity measurement of flow in the microchannel with barriers using Micro-PIV
    R. J. Wang
    J. Z. Lin
    H. B. Xie
    [J]. Journal of Visualization, 2006, 9 : 209 - 217
  • [22] Micro-PIV measurement of flow fields around adherent leukocytes
    Pickard, JE
    Pries, AR
    Ley, K
    [J]. FASEB JOURNAL, 2006, 20 (05): : A1322 - A1322
  • [23] Flow field visualization by Micro-PIV in an X-shaped microfluidic channel with two streams
    Shyu, Jin-Cherng
    Chen, Falin
    [J]. 2006 INTERNATIONAL CONFERENCE ON MEMS, NANO AND SMART SYSTEMS, PROCEEDINGS, 2006, : 1 - +
  • [24] On the effect of particle image intensity and image preprocessing on the depth of correlation in micro-PIV
    Massimiliano Rossi
    Rodrigo Segura
    Christian Cierpka
    Christian J. Kähler
    [J]. Experiments in Fluids, 2012, 52 : 1063 - 1075
  • [25] On the effect of particle image intensity and image preprocessing on the depth of correlation in micro-PIV
    Rossi, Massimiliano
    Segura, Rodrigo
    Cierpka, Christian
    Kaehler, Christian J.
    [J]. EXPERIMENTS IN FLUIDS, 2012, 52 (04) : 1063 - 1075
  • [26] Flow Analyses of a Contraction-Expansion Microchannel using micro-PIV
    Sharma, Vikas
    Dutta, Sushanta
    [J]. PROCEEDINGS OF THE 25TH NATIONAL AND 3RD INTERNATIONAL ISHMT-ASTFE HEAT AND MASS TRANSFER CONFERENCE, IHMTC 2019, 2019,
  • [27] Depth estimation method using depth-of-field imaging with a retroreflector
    Choi, Sungwon
    Min, Sung-Wook
    [J]. OPTICS EXPRESS, 2018, 26 (05): : 5655 - 5664
  • [28] The Measurements of Water Flow Rate in the T-shape Microchannels Based on the Scanning Micro-PIV Technique
    Han, W.
    Wang, H. L.
    Xu, M.
    [J]. RECENT PROGRESSES IN FLUID DYNAMICS RESEARCH - PROCEEDINGS OF THE SIXTH INTERNATIONAL CONFERENCE ON FLUID MECHANICS, 2011, 1376
  • [29] Micro-PIV study of flow and the formation of vortex in micro heat sinks with cavities and ribs
    Zhai, Yuling
    Xia, Guodong
    Chen, Zhuo
    Li, Zhouhang
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 98 : 380 - 389
  • [30] Measurement of transient electrokinetic flow in microchannels using micro-piv technique
    Yan, Deguang
    Yang, Chun
    Nguyen, Nam-Trung
    Huang, Xiaoyang
    [J]. PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNNELS, AND MINICHANNELS, PTS A AND B, 2006, : 223 - 231