Real-time sonoelastography using an external reference material: test-retest reliability of healthy Achilles tendons

被引:17
|
作者
Schneebeli, Alessandro [1 ]
Del Grande, Filippo [2 ]
Vincenzo, Gabriele [2 ]
Cescon, Corrado [1 ]
Clijsen, Ron [3 ,4 ,5 ]
Biordi, Fulvio [6 ]
Barbero, Marco [1 ]
机构
[1] Univ Appl Sci & Arts Southern Switzerland, Dept Business Econ Hlth & Social Care, Rehabil Res Lab 2rLab, Manno, Switzerland
[2] EOC, Osped Reg Lugano, Serv Radiol, Lugano, Switzerland
[3] Univ Appl Sci & Arts Southern Switzerland, Dept Business Econ Hlth & Social Care, Landquart, Switzerland
[4] Univ Coll Physiotherapy, Thim van der Laan AG, Landquart, Switzerland
[5] Vrije Univ Brussel, Fac Phys Educ & Phys Therapy, Brussels, Belgium
[6] ESAOTE SpA, Genoa, Italy
关键词
Sonoelastography; Achilles tendon; Reliability; SHEAR-WAVE ELASTOGRAPHY; ULTRASOUND ELASTOGRAPHY; PATTERN DESCRIPTION; TENDINOPATHY; MUSCLE; ELASTICITY; AGREEMENT; STIFFNESS; EXERCISE; ETIOLOGY;
D O I
10.1007/s00256-016-2382-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To establish the test-retest reliability of sonoelastography (SE) on healthy Achilles tendons in contracted and relaxed states using an external reference system. Forty-eight Achilles tendons from 24 healthy volunteers were assessed using ultrasound and real-time SE with an external reference material. Tendons were analyzed under relaxed and contracted conditions. Strain ratios between the tendons and the reference material were calculated. The intraclass correlation coefficient (ICC2.k) and Bland-Altman plot were used to assess test-retest reliability. The reliability of SE measurements under relaxed conditions ranged from high to very high, with an ICC2.k of 0.84 (95 % CI: 0.64-0.92) for reference material, 0.91 (95 % CI: 0.83-0.95) for Achilles tendons and 0.95 (95 % CI: 0.91-0.97) for Kager fat pads (KFP). The ICC2.k value for skin was 0.30 (95 % CI: -0.26 to 0.61). Reliability for measurements in the contracted state ranged from high to very high, with an ICC2.k of 0.93 (95 % CI: 0.87-0.96) for reference material, 0.72 (95 % CI: 0.50-0.84) for skin, 0.93 (95 % CI: 0.87-0.96) for Achilles tendons, and 0.81 (95 % CI: 0.66-0.89) for KFP. Reliability of the strain ratio (tendon/reference) under relaxed conditions was high with an ICC2.k of 0.87 (95 % CI: 0.75-0.93), and in the contracted state, it was very high with an ICC2.k of 0.94 (95 % CI: 0.90-0.97). Sonoelastography using an external reference material is a reliable and simple technique for the assessment of the elasticity of healthy Achilles tendons. The use of an external material as a reference, along with strain ratios, could provide a quantitative measure of elasticity.
引用
收藏
页码:1045 / 1052
页数:8
相关论文
共 50 条
  • [1] Real-time sonoelastography using an external reference material: test–retest reliability of healthy Achilles tendons
    Alessandro Schneebeli
    Filippo Del Grande
    Gabriele Vincenzo
    Corrado Cescon
    Ron Clijsen
    Fulvio Biordi
    Marco Barbero
    Skeletal Radiology, 2016, 45 : 1045 - 1052
  • [2] Real-Time Sonoelastography Findings in Healthy Achilles Tendons
    De Zordo, Tobias
    Fink, Christian
    Feuchtner, Gudrun M.
    Smekal, Vinzenz
    Reindl, Markus
    Klauser, Andrea Sabine
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (02) : W134 - W138
  • [3] Real-Time Sonoelastography: Findings in Patients with Symptomatic Achilles Tendons and Comparison to Healthy Volunteers
    De Zordo, T.
    Chhem, R.
    Smekal, V.
    Feuchtner, G.
    Reindl, M.
    Fink, C.
    Faschingbauer, R.
    Jaschke, W.
    Klauser, A. S.
    ULTRASCHALL IN DER MEDIZIN, 2010, 31 (04): : 394 - 400
  • [4] Test-retest reliability of echo intensity parameters in healthy Achilles tendons using a semi-automatic tracing procedure
    Schneebeli, Alessandro
    Del Grande, Filippo
    Vincenzo, Gabriele
    Cescon, Corrado
    Barbero, Marco
    SKELETAL RADIOLOGY, 2017, 46 (11) : 1553 - 1558
  • [5] Test-retest reliability of echo intensity parameters in healthy Achilles tendons using a semi-automatic tracing procedure
    Alessandro Schneebeli
    Filippo Del Grande
    Gabriele Vincenzo
    Corrado Cescon
    Marco Barbero
    Skeletal Radiology, 2017, 46 : 1553 - 1558
  • [6] Test-retest reliability of measuring the passive stiffness of the Achilles tendon using ultrasonography
    Mahieu, NN
    Witvrouw, E
    Stevens, V
    Willems, T
    Vanderstraeten, G
    ISOKINETICS AND EXERCISE SCIENCE, 2004, 12 (03) : 185 - 191
  • [7] Test-retest reliability of a balance testing protocol with external perturbations in young healthy adults
    Robbins, Shawn M.
    Caplan, Ryan M.
    Aponte, Daniel I.
    St-Onge, Nancy
    GAIT & POSTURE, 2017, 58 : 433 - 439
  • [8] Test-retest repeatability of articulatory strategies using real-time magnetic resonance imaging
    Sorensen, Tanner
    Toutios, Asterios
    Toger, Johannes
    Goldstein, Louis
    Narayanan, Shrikanth
    18TH ANNUAL CONFERENCE OF THE INTERNATIONAL SPEECH COMMUNICATION ASSOCIATION (INTERSPEECH 2017), VOLS 1-6: SITUATED INTERACTION, 2017, : 994 - 998
  • [9] Test-Retest Reliability of Eye Tracking in the Visual World Paradigm for the Study of Real-Time Spoken Word Recognition
    Farris-Trimble, Ashley
    McMurray, Bob
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2013, 56 (04): : 1328 - 1345
  • [10] Real-time sonoelastography of the patellar and quadriceps tendons: pattern description in profesional athletes and healthy volunteers.
    Ozcan, Ayse Nur Sirin
    Tan, Sinan
    Tangal, Nuray Gulden
    Ciraci, Saliha
    Kudas, Savas
    Bektaser, Suleyman Bulent
    Arslan, Halil
    MEDICAL ULTRASONOGRAPHY, 2016, 18 (03) : 299 - 304