Comparison of two methods for enhanced continuous circulatory monitoring in patients with septic shock

被引:22
|
作者
Spoehr, F. [1 ]
Hettrich, P. [1 ]
Bauer, H. [1 ]
Haas, U. [1 ]
Martin, E. [1 ]
Boettiger, B. W. [1 ]
机构
[1] Univ Heidelberg, Dept Anaesthesiol, D-69120 Heidelberg, Germany
关键词
cardiac output; central venous pressure; continuous monitoring; global end-diastolic volume; pulmonary artery occlusion pressure; right ventricular end-diastolic volume; septic shock;
D O I
10.1007/s00134-007-0703-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To compare a modified pulmonary artery catheter (PAC) and pulse-contour analysis by the PiCCO (Pulsion Medical Systems, Munich, Germany) system for continuous assessment of cardiac output in patients with septic shock. In addition, to assess the relationships between an index of global end-diastolic volume (GEDV) derived by the PiCCO system with traditional PAC-derived indicators of filling: central venous pressure; pulmonary artery occlusion pressure; and right ventricular end- diastolic volume (RVEDV). Design: Prospective cohort study. Setting: Surgical intensive care unit of a university hospital. Patients and participants: 14 patients with septic shock. Interventions: None. Measurements and results: A significant correlation was found between continuous cardiac output by PAC ( CCOPAC) and by pulse-contour analysis (r(2) = 0.714, p < 0.0001), accompanied by a bias of 0.11 min(-1) and a precision of 2.71 min(-1). The correlation between CCOPAC and cardiac output measured by transcardiopulmonary thermodilution was also significant (r(2) = 0.781, < 0.0001). There was a bias for the two methods of 0.21 min(-1), and a precision of 2.21 min(-1). The GEDV showed no correlation with central venous pressure, pulmonary artery occlusion pressure, or RVEDV. Conclusion: In patients with septic shock, the averaged bias in continuous measurement of cardiac output by both a modified pulmonary artery catheter and pulse- contour analysis was small, but variability was large. No correlation was found between GEDV and RVEDV. The clinical importance of different cardiac filling parameters needs further investigation.
引用
收藏
页码:1805 / 1810
页数:6
相关论文
共 50 条
  • [21] Continuous Hemodiafiltration with PMMA Hemofilter in the Treatment of Patients with Septic Shock
    Taka-aki Nakada
    Shigeto Oda
    Ken-ichi Matsuda
    Tomohito Sadahiro
    Masataka Nakamura
    Ryuzo Abe
    Hiroyuki Hirasawa
    Molecular Medicine, 2008, 14 : 257 - 263
  • [22] Continuous hemodiafiltration with PMMA hemofilter in the treatment of patients with septic shock
    Nakada, Taka-aki
    Oda, Shigeto
    Matsuda, Ken-ichi
    Sadahiro, Tomohito
    Nakamura, Masataka
    Abe, Ryuzo
    Hirasawa, Hiroyuki
    MOLECULAR MEDICINE, 2008, 14 (5-6) : 257 - 263
  • [23] AUTOMATIC URINOMETER FOR ON-LINE MONITORING OF PATIENTS WITH CIRCULATORY SHOCK
    MEAGHER, PF
    JENSEN, RE
    PEARCY, MG
    WEIL, MH
    SHUBIN, H
    MEDICAL RESEARCH ENGINEERING, 1966, 5 (04) : 38 - &
  • [24] Systemic hemodynamic during continuous hemodiafiltration in patients with septic shock
    O Mouravev
    I Iakovleva
    E Pestriakov
    Critical Care, 8 (Suppl 1):
  • [25] Effect of two volume responsiveness evaluation methods on fluid resuscitation and prognosis in septic shock patients
    Xu Qianghong
    Yan Jing
    Cai Guolong
    Chen Jin
    Li Li
    Hu Caibao
    CHINESE MEDICAL JOURNAL, 2014, 127 (03) : 483 - 487
  • [26] Effect of two volume responsiveness evaluation methods on fluid resuscitation and prognosis in septic shock patients
    Xu Qianghong
    Yan Jing
    Cai Guolong
    Chen Jin
    Li Li
    Hu Caibao
    中华医学杂志(英文版), 2014, 127 (03) : 483 - 487
  • [27] CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION IN SEPTIC SHOCK - REPLY
    HEISELMAN, D
    JONES, J
    CANNON, L
    JOURNAL OF CLINICAL MONITORING, 1987, 3 (03): : 214 - 214
  • [28] MONITORING IL-7 PATHWAY IN SEPTIC SHOCK PATIENTS
    Venet, F.
    Villars-Mechin, A.
    Pottier, A.
    Lepape, A.
    Monneret, G.
    INTENSIVE CARE MEDICINE, 2011, 37 : S219 - S219
  • [29] Sublingual PCO2 monitoring in patients with septic shock
    Creteur, J
    De Backer, D
    Sakr, Y
    Vincent, JL
    CRITICAL CARE MEDICINE, 2002, 30 (12) : A19 - A19
  • [30] COMPARISON OF TWO LEVELS OF MEAN ARTERIAL PRESSURE ON SURVIVAL IN PATIENTS WITH SEPTIC SHOCK: SEPSISPAM TRIAL
    Asfar, P.
    Meziani, F.
    Hamel, J. F.
    Grelon, F.
    Megarbane, B.
    Anguel, N.
    Mira, J. P.
    Dequin, P. F.
    Gergaud, S.
    Weiss, N.
    Legay, F.
    Le Tulzo, Y.
    Conrad, M.
    Robert, R.
    Gonzalez, F.
    Nicolet, L.
    Tamion, F.
    Tonnelier, J. M.
    Teboul, J. L.
    Radermarther, P.
    INTENSIVE CARE MEDICINE, 2013, 39 : S338 - S339