Comparison of two methods for enhanced continuous circulatory monitoring in patients with septic shock

被引:22
|
作者
Spoehr, F. [1 ]
Hettrich, P. [1 ]
Bauer, H. [1 ]
Haas, U. [1 ]
Martin, E. [1 ]
Boettiger, B. W. [1 ]
机构
[1] Univ Heidelberg, Dept Anaesthesiol, D-69120 Heidelberg, Germany
关键词
cardiac output; central venous pressure; continuous monitoring; global end-diastolic volume; pulmonary artery occlusion pressure; right ventricular end-diastolic volume; septic shock;
D O I
10.1007/s00134-007-0703-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To compare a modified pulmonary artery catheter (PAC) and pulse-contour analysis by the PiCCO (Pulsion Medical Systems, Munich, Germany) system for continuous assessment of cardiac output in patients with septic shock. In addition, to assess the relationships between an index of global end-diastolic volume (GEDV) derived by the PiCCO system with traditional PAC-derived indicators of filling: central venous pressure; pulmonary artery occlusion pressure; and right ventricular end- diastolic volume (RVEDV). Design: Prospective cohort study. Setting: Surgical intensive care unit of a university hospital. Patients and participants: 14 patients with septic shock. Interventions: None. Measurements and results: A significant correlation was found between continuous cardiac output by PAC ( CCOPAC) and by pulse-contour analysis (r(2) = 0.714, p < 0.0001), accompanied by a bias of 0.11 min(-1) and a precision of 2.71 min(-1). The correlation between CCOPAC and cardiac output measured by transcardiopulmonary thermodilution was also significant (r(2) = 0.781, < 0.0001). There was a bias for the two methods of 0.21 min(-1), and a precision of 2.21 min(-1). The GEDV showed no correlation with central venous pressure, pulmonary artery occlusion pressure, or RVEDV. Conclusion: In patients with septic shock, the averaged bias in continuous measurement of cardiac output by both a modified pulmonary artery catheter and pulse- contour analysis was small, but variability was large. No correlation was found between GEDV and RVEDV. The clinical importance of different cardiac filling parameters needs further investigation.
引用
收藏
页码:1805 / 1810
页数:6
相关论文
共 50 条
  • [1] Comparison of two methods for enhanced continuous circulatory monitoring in patients with septic shock
    F. Spöhr
    P. Hettrich
    H. Bauer
    U. Haas
    E. Martin
    B. W. Böttiger
    Intensive Care Medicine, 2007, 33 : 1805 - 1810
  • [2] Assessment of neutrophil function in patients with septic shock:: Comparison of methods
    Wenisch, C
    Fladerer, P
    Patruta, S
    Krause, R
    Hörl, W
    CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2001, 8 (01) : 178 - 180
  • [3] Circulatory markers and mediators in plasma of patients with septic shock.
    Hartemink, KJ
    Groeneveld, ABJ
    SHOCK, 1999, 12 : 42 - 43
  • [4] FLUID RESUSCITATION IN CIRCULATORY SHOCK - A COMPARISON OF THE CARDIORESPIRATORY EFFECTS OF ALBUMIN, HETASTARCH, AND SALINE SOLUTIONS IN PATIENTS WITH HYPOVOLEMIC AND SEPTIC SHOCK
    RACKOW, EC
    FALK, JL
    FEIN, IA
    SIEGEL, JS
    PACKMAN, MI
    HAUPT, MT
    KAUFMAN, BS
    PUTNAM, D
    CRITICAL CARE MEDICINE, 1983, 11 (11) : 839 - 850
  • [5] Continuous hemofiltration in hyperthermic septic shock patients
    Pestana, David
    Casanova, Elena
    Villagran, Maria J.
    Tormo, Carolina
    Perez-Chrzanowska, Hanna
    Redondo, Javier
    Caldera, Mara V.
    Royo, Concepcion
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2007, 63 (04): : 751 - 756
  • [6] Multicenter comparison of cortisol as measured by different methods in samples of patients with septic shock
    Briegel, Josef
    Sprung, Charles L.
    Annane, Djillali
    Singer, Mervyn
    Keh, Didier
    Moreno, Rui
    Moehnle, Patrick
    Weiss, Yoram
    Avidan, Alexander
    Brunkhorst, Frank M.
    Fiedler, Fritz
    Vogeser, Michael
    INTENSIVE CARE MEDICINE, 2009, 35 (12) : 2151 - 2156
  • [7] Multicenter comparison of cortisol as measured by different methods in samples of patients with septic shock
    Josef Briegel
    Charles L. Sprung
    Djillali Annane
    Mervyn Singer
    Didier Keh
    Rui Moreno
    Patrick Möhnle
    Yoram Weiss
    Alexander Avidan
    Frank M. Brunkhorst
    Fritz Fiedler
    Michael Vogeser
    Intensive Care Medicine, 2009, 35 : 2151 - 2156
  • [8] Sublingual PCO, monitoring in patients with septic shock
    Creteur, J
    De Backer, D
    Sakr, Y
    Vincent, J
    INTENSIVE CARE MEDICINE, 2003, 29 : S10 - S10
  • [9] Comparison of two different corticotropin stimulation tests in septic shock patients.
    Van Haren, FMP
    Boon, ES
    Van der Hoeven, JG
    INTENSIVE CARE MEDICINE, 2002, 28 : S75 - S75
  • [10] Comparison of the circulatory effects of continuous renal replacement therapy using AN69ST and polysulfone membranes in septic shock patients: A retrospective observational study
    Shibata, Mami
    Miyamoto, Kyohei
    Kato, Seiya
    THERAPEUTIC APHERESIS AND DIALYSIS, 2020, 24 (05) : 561 - 567