Manganese(III) Porphyrin-based Potentiometric Sensors for Diclofenac Assay in Pharmaceutical Preparations

被引:35
|
作者
Vlascici, Dana [1 ]
Pruneanu, Stela [2 ]
Olenic, Liliana [2 ]
Pogacean, Florina [2 ]
Ostafe, Vasile [1 ]
Chiriac, Vlad [1 ]
Pica, Elena Maria [3 ]
Bolundut, Liviu Calm [3 ]
Nica, Luminita [4 ]
Fagadar-Cosma, Eugenia [5 ]
机构
[1] W Univ Timisoara, Timisoara 300223, Timis, Romania
[2] Natl Inst Res & Dev Isotop & Mol Technol, Cluj Napoca 400293, Romania
[3] Tech Univ Cluj Napoca, Fac Sci & Mat Engn, Cluj Napoca 400114, Romania
[4] Victor Babes Univ Med & Pharm Timisoara, Timisoara, Romania
[5] Timisora Romanian Acad, Inst Chem, Timisoara 300223, Romania
来源
SENSORS | 2010年 / 10卷 / 10期
关键词
diclofenac; manganese porphyrins; ion-selective electrodes; potentiometry; electrochemical impedance spectroscopy; pharmaceuticals; ION-SELECTIVE ELECTRODES; RESPONSE PROPERTIES; PVC; MEMBRANES; IONOPHORES; MN(III)TPP-CL; SUBSTITUENTS; FORMULATIONS; ASSOCIATE; EXCHANGE;
D O I
10.3390/s101008850
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two manganese(III) porphyrins: manganese(III) tetraphenylporphyrin chloride and manganese(III)-tetrakis(3-hydroxyphenyl)porphyrin chloride were tested as ionophores for the construction of new diclofenac selective electrodes. The electroactive material was incorporated either in PVC or a sol gel matrix. The effect of different plasticizers and additives (anionic and cationic) on the potentiometric response was studied. The best results were obtained for the PVC membrane plasticized with dioctylphtalate and having sodium tetraphenylborate as a lipophilic anionic additive incorporated. The sensor response was linear in the concentration range 3 x 10(-6) - 1 x 10(-2) M with a slope of -59.7 mV/dec diclofenac, a detection limit of 1.5 x 10(-6) M and very good selectivity coefficients. It was used for the determination of diclofenac in pharmaceutical preparations, by direct potentiometry. The results were compared with those obtained by the HPLC reference method and a good agreement was found between the two methods.
引用
收藏
页码:8850 / 8864
页数:15
相关论文
共 50 条
  • [21] Continuous potentiometric monitoring of viagra (sildenafil) in pharmaceutical preparations using novel membrane sensors
    Hassan, SSM
    Elnemma, EM
    Mahmoud, WH
    Mohammed, AHK
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2006, 36 (02) : 139 - 146
  • [22] Polymeric matrix membrane sensors for sensitive potentiometric determination of some β-blockers in pharmaceutical preparations
    Hassan, SSM
    Abou-Sekkina, MM
    El-Ries, MA
    Wassel, AA
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 32 (01) : 175 - 180
  • [23] Membrane sensors for batch and flow injection potentiometric determination of ethamsylate (Cyclonamine) in pharmaceutical preparations
    Hassan, SSM
    ElBahnasawy, RM
    Rizk, NM
    MIKROCHIMICA ACTA, 1997, 126 (3-4) : 217 - 222
  • [24] Potentiometric Sensors for Iodide and Bromide Based on Pt(II)-Porphyrin
    Vlascici, Dana
    Plesu, Nicoleta
    Fagadar-Cosma, Gheorghe
    Lascu, Anca
    Petric, Mihaela
    Crisan, Manuela
    Belean, Anca
    Fagadar-Cosma, Eugenia
    SENSORS, 2018, 18 (07)
  • [25] BODIPY- and Porphyrin-Based Sensors for Recognition of Amino Acids and Their Derivatives
    Farinone, Marco
    Urbanska, Karolina
    Pawlicki, Milosz
    MOLECULES, 2020, 25 (19):
  • [26] Development of porphyrin-based fluorescent sensors and sensor arrays for saccharide recognition
    Ding, Yubin
    Wang, Jiaxin
    Wang, Ruinan
    Xie, Yongshu
    CHINESE CHEMICAL LETTERS, 2024, 35 (02)
  • [27] Porphyrin-based chemical sensors and multisensor arrays operating in the liquid phase
    Lvova, Larisa
    Di Natale, Corrado
    Paolesse, Roberto
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 179 : 21 - 31
  • [28] Development of porphyrin-based fluorescent sensors and sensor arrays for saccharide recognition
    Yubin Ding
    Jiaxin Wang
    Ruinan Wang
    Yongshu Xie
    ChineseChemicalLetters, 2024, 35 (02) : 44 - 51
  • [29] Development of Novel Potentiometric Sensors for Determination of Lidocaine Hydrochloride in Pharmaceutical Preparations, Serum and Urine Samples
    Ali, Tamer Awad
    Mohamed, Gehad Genidy
    Yahya, Ghada A.
    IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH, 2017, 16 (02): : 498 - 512
  • [30] Determination of pyridoxine hydrochloride in pharmaceutical preparations by calixarene based potentiometric sensor
    Vaze, V. D.
    Srivastava, A. K.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 47 (01) : 177 - 182