Manganese(III) Porphyrin-based Potentiometric Sensors for Diclofenac Assay in Pharmaceutical Preparations

被引:35
|
作者
Vlascici, Dana [1 ]
Pruneanu, Stela [2 ]
Olenic, Liliana [2 ]
Pogacean, Florina [2 ]
Ostafe, Vasile [1 ]
Chiriac, Vlad [1 ]
Pica, Elena Maria [3 ]
Bolundut, Liviu Calm [3 ]
Nica, Luminita [4 ]
Fagadar-Cosma, Eugenia [5 ]
机构
[1] W Univ Timisoara, Timisoara 300223, Timis, Romania
[2] Natl Inst Res & Dev Isotop & Mol Technol, Cluj Napoca 400293, Romania
[3] Tech Univ Cluj Napoca, Fac Sci & Mat Engn, Cluj Napoca 400114, Romania
[4] Victor Babes Univ Med & Pharm Timisoara, Timisoara, Romania
[5] Timisora Romanian Acad, Inst Chem, Timisoara 300223, Romania
来源
SENSORS | 2010年 / 10卷 / 10期
关键词
diclofenac; manganese porphyrins; ion-selective electrodes; potentiometry; electrochemical impedance spectroscopy; pharmaceuticals; ION-SELECTIVE ELECTRODES; RESPONSE PROPERTIES; PVC; MEMBRANES; IONOPHORES; MN(III)TPP-CL; SUBSTITUENTS; FORMULATIONS; ASSOCIATE; EXCHANGE;
D O I
10.3390/s101008850
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two manganese(III) porphyrins: manganese(III) tetraphenylporphyrin chloride and manganese(III)-tetrakis(3-hydroxyphenyl)porphyrin chloride were tested as ionophores for the construction of new diclofenac selective electrodes. The electroactive material was incorporated either in PVC or a sol gel matrix. The effect of different plasticizers and additives (anionic and cationic) on the potentiometric response was studied. The best results were obtained for the PVC membrane plasticized with dioctylphtalate and having sodium tetraphenylborate as a lipophilic anionic additive incorporated. The sensor response was linear in the concentration range 3 x 10(-6) - 1 x 10(-2) M with a slope of -59.7 mV/dec diclofenac, a detection limit of 1.5 x 10(-6) M and very good selectivity coefficients. It was used for the determination of diclofenac in pharmaceutical preparations, by direct potentiometry. The results were compared with those obtained by the HPLC reference method and a good agreement was found between the two methods.
引用
收藏
页码:8850 / 8864
页数:15
相关论文
共 50 条
  • [1] Manganese(III) Porphyrin-Based Magnetic Materials
    Zhang, Daopeng
    Lan, Wenlong
    Zhou, Zhen
    Yang, Lu
    Liu, Qingyun
    Bian, Yongzhong
    Jiang, Jianzhuang
    TOPICS IN CURRENT CHEMISTRY, 2019, 377 (03)
  • [2] Manganese(III) Porphyrin-Based Magnetic Materials
    Daopeng Zhang
    Wenlong Lan
    Zhen Zhou
    Lu Yang
    Qingyun Liu
    Yongzhong Bian
    Jianzhuang Jiang
    Topics in Current Chemistry, 2019, 377
  • [3] A manganese porphyrin-based sensor for flow-injection potentiometric determination of thiocyanate
    Beheshti, Saeed S.
    Sohbat, Fatemeh
    Amini, Mohammad K.
    JOURNAL OF PORPHYRINS AND PHTHALOCYANINES, 2010, 14 (02) : 158 - 165
  • [4] Sensing of diclofenac by a porphyrin-based artificial receptor
    Intrieri, Daniela
    Damiano, Caterina
    Rizzato, Silvia
    Paolesse, Roberto
    Venanzi, Mariano
    Monti, Donato
    Savioli, Marco
    Stefanelli, Manuela
    Gallo, Emma
    NEW JOURNAL OF CHEMISTRY, 2018, 42 (19) : 15778 - 15783
  • [5] Potentiometric Sensors for the Determination of Trifluoperazine Hydrochloride in Pharmaceutical Preparations
    Hassan, Ahmed K.
    Ameen, Suhaam T.
    Saad, Bahruddin
    Al-Aragi, Suad M.
    ANALYTICAL SCIENCES, 2009, 25 (11) : 1295 - 1299
  • [6] Potentiometric Sensors for the Determination of Trifluoperazine Hydrochloride in Pharmaceutical Preparations
    Ahmed K. Hassan
    Suhaam T. Ameen
    Bahruddin Saad
    Suad M. Al-Aragi
    Analytical Sciences, 2009, 25 : 1295 - 1299
  • [7] Potentiometric membrane sensors for the selective determination of cinnarizine in pharmaceutical preparations
    Hassan, SSM
    AbdelAziz, RM
    Abbas, AB
    ANALYTICA CHIMICA ACTA, 1996, 321 (01) : 47 - 52
  • [8] Determination of diclofenac in pharmaceutical preparations using a potentiometric sensor immobilized in a graphite matrix
    Santini, AO
    Pezza, HR
    Pezza, L
    TALANTA, 2006, 68 (03) : 636 - 642
  • [9] POTENTIOMETRIC ASSAY OF PURINE BASES BY ARGENTIMETRY - APPLICATIONS TO PHARMACEUTICAL PREPARATIONS
    PELLERIN, F
    LEROUXMA.G
    ANNALES PHARMACEUTIQUES FRANCAISES, 1968, 26 (05): : 414 - &
  • [10] RAPID AND SIMPLIFIED ASSAY FOR THYROID IN PHARMACEUTICAL PREPARATIONS BY POTENTIOMETRIC TITRATION
    RICHHEIMER, SL
    SCHACHET, MS
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1983, 72 (07) : 822 - 823