New biodegradable drug-eluting stents for urethral strictures in a rabbit model

被引:6
|
作者
Wang, Zhong-Xin [1 ]
Hong, Bao-Fa [1 ]
Zhang, Xu [1 ]
Fu, Wei-Jun [1 ]
Cui, Fu-Zhai [2 ]
Hu, Kun [2 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Mil Postgrad Med Coll, Dept Urol, Beijing 100853, Peoples R China
[2] Tsinghua Univ, Dept Mat Sci & Engn, Adv Mat Lab, Beijing 100084, Peoples R China
关键词
biodegradable; drug-eluting stents; paclitaxel-eluting stents; urethral strictures; BLADDER-OUTFLOW OBSTRUCTION; BIOCOMPATIBILITY;
D O I
10.1177/0883911510391452
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In this study, the feasibility and the effect of a new biodegradable drug-eluting urethral stents for the treatment of urethral stricture in a rabbit model were evaluated, and the biocompatibility properties of the new biodegradable drug-eluting urethral stents in the rabbit urethral assessed. A total of 34 male New Zealand White rabbits with urethral strictures were used, and equally divided into two groups: with drug stents and drug-free stents. The urethral strictures were made by using a self-control explosion device as the control. Stents were surgically implanted into the stenotic urethras of rabbits under direct vision. Reparative effects, including biocompatibility assessment, were evaluated by urethroscopy, retrograde urethrography, and histology at different intervals at weeks 4, 8, and 12. Although retrograde urethrography and urodynamic results at 12 weeks showed no comparable differences among the three groups, urethroscopic and histological follow-up indicated that the drug stents had minimized the stent-related inflammatory responses, urothelial hyperplasia, and scar formation compared with the drug-free stents. The new biodegradable paclitaxel-eluting stents were more biocompatible and effective for treating urethral strictures in the rabbit model than the drug-free stents.
引用
收藏
页码:89 / 98
页数:10
相关论文
共 50 条
  • [31] New Drug-eluting Stents: Polymer-free, Biodegradable Polymers or Bioabsorbable Scaffolds?
    Alfonso, Fernando
    [J]. REVISTA ESPANOLA DE CARDIOLOGIA, 2013, 66 (06): : 423 - 426
  • [32] New drug-eluting stents under study
    Mitka, Mike
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 297 (19): : 2064 - +
  • [33] Drug-eluting stents: is new necessarily better?
    Waksman, Ron
    [J]. LANCET, 2008, 372 (9644): : 1126 - 1128
  • [34] Drug-eluting stents: new era and new concerns
    Bhatia, V
    Bhatia, R
    Dhindsa, M
    [J]. POSTGRADUATE MEDICAL JOURNAL, 2004, 80 (939) : 13 - 18
  • [35] Domestic New-generation Drug-eluting Stents Versus Imported New-generation Drug-eluting Stents in China
    Liu, Ru
    Gao, Zhan
    Ma Yuanliang
    Song, Ying
    Wang, Huanhuan
    Jiang, Lin
    Gao, Lijian
    Qiao, Shubin
    Yang, Yuejin
    Gao, Runlin
    Xu, Bo
    Yuan, Jinqing
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (15) : S69 - S70
  • [36] Drug-eluting stents or drug-eluting conduits for multivessel disease?
    Alfieri, Ottavio
    Maisano, Francesco
    Benussi, Stefano
    Toracca, Lucia
    Castiglioni, Alessandro
    [J]. JOURNAL OF CARDIOVASCULAR MEDICINE, 2007, 8 (05) : 359 - 361
  • [37] Improved clinical outcome with biodegradable polymer drug-eluting stents compared to durable polymer drug-eluting stents for primary percutaneous coronary intervention
    Andriyati, Ratna
    Firman, Doni
    Kurniawati, Yovi
    Alkatiri, Amir Aziz
    Pranata, Raymond
    Muliawan, Hary Sakti
    Rossimarina, Vienna
    Soerianata, Sunarya
    [J]. POSTGRADUATE MEDICAL JOURNAL, 2021, 97 (1152) : 638 - 643
  • [38] Drug-eluting stents with biodegradable polymers: are enough data in for a final assessment?
    Pfisterer, Matthias
    Kaiser, Christoph
    [J]. EUROPEAN HEART JOURNAL, 2014, 35 (17) : 1098 - 1100
  • [39] Angiographic Outcomes With Biodegradable Polymer and Permanent Polymer Drug-Eluting Stents
    Kufner, Sebastian
    Massberg, Steffen
    Dommasch, Michael
    Byrne, Robert A.
    Tiroch, Klaus
    Ranftl, Sabine
    Fusaro, Massimiliano
    Schoemig, Albert
    Kastrati, Adnan
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 78 (02) : 161 - 166
  • [40] NEOINTIMAL COVERAGE PATTERNS IN BIODEGRADABLE VASCULAR SCAFFOLD AND DRUG-ELUTING STENTS
    Agasthi, Pradyumna
    Aloor, Sivakanth
    Chaudhry, Aneese
    Lee, Kwan
    Kumar, Gautam
    Sachdeva, Rajesh
    [J]. CRITICAL CARE MEDICINE, 2016, 44 (12)