Camera-based assessment of cutaneous perfusion strength in a clinical setting

被引:6
|
作者
Hammer, Alexander [1 ]
Scherpf, Matthieu [1 ]
Schmidt, Martin [1 ]
Ernst, Hannes [1 ]
Malberg, Hagen [1 ]
Matschke, Klaus [2 ]
Dragu, Adrian [3 ]
Martin, Judy [3 ]
Bota, Olimpiu [3 ]
机构
[1] Tech Univ Dresden, Inst Biomed Engn, Fetscherstr 29, D-01307 Dresden, Germany
[2] Tech Univ Dresden, Dept Cardiac Surg, Univ Heart Ctr Dresden, Dresden, Germany
[3] Tech Univ Dresden, Fac Med Carl Gustav Carus, Univ Ctr Orthoped Trauma & Plast Surg, Dresden, Germany
基金
欧盟地平线“2020”;
关键词
camera-based photoplethysmography; remote measurement; non-contact; perfusion strength; skin flap transplants; TISSUE; FLAP; PHOTOPLETHYSMOGRAPHY; SKIN;
D O I
10.1088/1361-6579/ac557d
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective. After skin flap transplants, perfusion strength monitoring is essential for the early detection of tissue perfusion disorders and thus to ensure the survival of skin flaps. Camera-based photoplethysmography (cbPPG) is a non-contact measurement method, using video cameras and ambient light, which provides spatially resolved information about tissue perfusion. It has not been researched yet whether the measurement depth of cbPPG, which is limited by the penetration depth of ambient light, is sufficient to reach pulsatile vessels and thus to measure the perfusion strength in regions that are relevant for skin flap transplants. Approach. We applied constant negative pressure (compared to ambient pressure) to the anterior thighs of 40 healthy subjects. Seven measurements (two before and five up to 90 min after the intervention) were acquired using an RGB video camera and photospectrometry simultaneously. We investigated the performance of different algorithmic approaches for perfusion strength assessment, including the signal-to-noise ratio (SNR), its logarithmic components logS and logN, amplitude maps, and the amplitude height of alternating and direct signal components. Main results. We found strong correlations of up to r = 0.694 (p < 0.001) between photospectrometric measurements and all cbPPG parameters except SNR when using the green color channel. The transfer of cbPPG signals to POS, CHROM, and O3C did not lead to systematic improvements. However, for direct signal components, the transformation to O3C led to correlations of up to r = 0.744 (p < 0.001) with photospectrometric measurements. Significance. Our results indicate that a camera-based perfusion strength assessment in tissue with deep-seated pulsatile vessels is possible.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Camera-based measurement of vital signs
    Haist, Tobias
    Reichert, Carsten
    Wuertenberger, Felicia
    Lachenmaier, Lena
    Faulhaber, Andreas
    TM-TECHNISCHES MESSEN, 2019, 86 (7-8) : 354 - 361
  • [32] Camera-based driver assistance systems
    Grimm, Michael
    ADVANCED OPTICAL TECHNOLOGIES, 2013, 2 (02) : 131 - 140
  • [33] Verification of Camera-Based Autonomous Systems
    Habeeb, P.
    Deka, Nabarun
    D'Souza, Deepak
    Lodaya, Kamal
    Prabhakar, Pavithra
    IEEE TRANSACTIONS ON COMPUTER-AIDED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, 2023, 42 (10) : 3450 - 3463
  • [34] Camera-based document image mosaicing
    Liang, Han
    DeMenthon, Daniel
    Doermann, David
    18TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION, VOL 2, PROCEEDINGS, 2006, : 476 - +
  • [35] Exploiting Dual-Wavelength Depolarization of Skin-Tissues for Camera-Based Perfusion Monitoring
    Huang, Liyuan
    Ye, Fangfan
    Shu, Huaijing
    Huang, Yukai
    Wang, Song
    Wu, Qiang
    Lu, Hongzhou
    Wang, Wenjin
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2025, 72 (01) : 358 - 369
  • [36] On validating a generic camera-based blink detection system for cognitive load assessment
    Biondi, Francesco N.
    Graf, Frida
    Pillai, Prarthana
    Balasingam, Balakumar
    COGNITIVE COMPUTATION AND SYSTEMS, 2023, 5 (04) : 255 - 264
  • [37] Camera-Based Selection with Cardboard HMDs
    Luo, Siqi
    Teather, Robert J.
    2019 26TH IEEE CONFERENCE ON VIRTUAL REALITY AND 3D USER INTERFACES (VR), 2019, : 1066 - 1067
  • [38] Mobile camera-based user interaction
    Haro, A
    Mori, K
    Capin, T
    Wilkinson, S
    COMPUTER VISION IN HUMAN-COMPUTER INTERACTION, PROCEEDINGS, 2005, 3766 : 79 - 89
  • [39] Validation of Amazon Halo Movement: a smartphone camera-based assessment of movement health
    Michael Fanton
    Yaar Harari
    Matthew Giffhorn
    Allie Lynott
    Eli Alshan
    Jonathan Mendley
    Madeline Czerwiec
    Rebecca Macaluso
    Ianir Ideses
    Eduard Oks
    Arun Jayaraman
    npj Digital Medicine, 5
  • [40] Camera-Based Respiratory Imaging for Intelligent Rehabilitation Assessment of Thoracic Surgery Patients
    Huang, Dongmin
    Tao, Xiaoting
    Huang, Yukai
    Wang, Yanfeng
    Zhu, Yingen
    Qiao, Kun
    Lu, Hongzhou
    Wang, Wenjin
    IEEE INTERNET OF THINGS JOURNAL, 2024, 11 (15): : 26253 - 26265