Camera-based assessment of cutaneous perfusion strength in a clinical setting

被引:6
|
作者
Hammer, Alexander [1 ]
Scherpf, Matthieu [1 ]
Schmidt, Martin [1 ]
Ernst, Hannes [1 ]
Malberg, Hagen [1 ]
Matschke, Klaus [2 ]
Dragu, Adrian [3 ]
Martin, Judy [3 ]
Bota, Olimpiu [3 ]
机构
[1] Tech Univ Dresden, Inst Biomed Engn, Fetscherstr 29, D-01307 Dresden, Germany
[2] Tech Univ Dresden, Dept Cardiac Surg, Univ Heart Ctr Dresden, Dresden, Germany
[3] Tech Univ Dresden, Fac Med Carl Gustav Carus, Univ Ctr Orthoped Trauma & Plast Surg, Dresden, Germany
基金
欧盟地平线“2020”;
关键词
camera-based photoplethysmography; remote measurement; non-contact; perfusion strength; skin flap transplants; TISSUE; FLAP; PHOTOPLETHYSMOGRAPHY; SKIN;
D O I
10.1088/1361-6579/ac557d
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective. After skin flap transplants, perfusion strength monitoring is essential for the early detection of tissue perfusion disorders and thus to ensure the survival of skin flaps. Camera-based photoplethysmography (cbPPG) is a non-contact measurement method, using video cameras and ambient light, which provides spatially resolved information about tissue perfusion. It has not been researched yet whether the measurement depth of cbPPG, which is limited by the penetration depth of ambient light, is sufficient to reach pulsatile vessels and thus to measure the perfusion strength in regions that are relevant for skin flap transplants. Approach. We applied constant negative pressure (compared to ambient pressure) to the anterior thighs of 40 healthy subjects. Seven measurements (two before and five up to 90 min after the intervention) were acquired using an RGB video camera and photospectrometry simultaneously. We investigated the performance of different algorithmic approaches for perfusion strength assessment, including the signal-to-noise ratio (SNR), its logarithmic components logS and logN, amplitude maps, and the amplitude height of alternating and direct signal components. Main results. We found strong correlations of up to r = 0.694 (p < 0.001) between photospectrometric measurements and all cbPPG parameters except SNR when using the green color channel. The transfer of cbPPG signals to POS, CHROM, and O3C did not lead to systematic improvements. However, for direct signal components, the transformation to O3C led to correlations of up to r = 0.744 (p < 0.001) with photospectrometric measurements. Significance. Our results indicate that a camera-based perfusion strength assessment in tissue with deep-seated pulsatile vessels is possible.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Camera-based photoplethysmography in an intraoperative setting
    Alexander Trumpp
    Johannes Lohr
    Daniel Wedekind
    Martin Schmidt
    Matthias Burghardt
    Axel R. Heller
    Hagen Malberg
    Sebastian Zaunseder
    BioMedical Engineering OnLine, 17
  • [2] Camera-based photoplethysmography in an intraoperative setting
    Trumpp, Alexander
    Lohr, Johannes
    Wedekind, Daniel
    Schmidt, Martin
    Burghardt, Matthias
    Heller, Axel R.
    Malberg, Hagen
    Zaunseder, Sebastian
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [3] Analyses of Isokinetic Thigh Muscle Strength: Camera-Based Assessment Alters the Magnitude, but Not the Message
    Alt, Tobias
    Nolte, Kevin
    Horn, Dennis
    Modenbach, Dominik
    Knicker, Axel J.
    Jaitner, Thomas
    RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2023, 94 (03) : 783 - 792
  • [4] A CMOS camera-based system for clinical photoplethysmographic applications
    Humphreys, K
    Markham, C
    Ward, TE
    OPTO-IRELAND 2005: IMAGING AND VISION, 2005, 5823 : 88 - 95
  • [5] Camera-based Plantar Perfusion Imaging for Detecting Lower Limb Arterial Blockage
    Huang, Yukai
    Huang, Dongmin
    Wu, Jia
    Lu, Hongzhou
    He, Min
    Wang, Wenjin
    2023 IEEE EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL AND HEALTH INFORMATICS, BHI, 2023,
  • [6] A camera-based multispectral setup for remote vital signs assessment
    Paul, M.
    Venema, B.
    Blazek, V.
    Muhlsteff, J.
    Leonhardt, S.
    EMBEC & NBC 2017, 2018, 65 : 968 - 971
  • [7] Raindrops on the Windshield: Performance Assessment of Camera-based Object Detection
    Hasirlioglu, Sinan
    Reway, Fabio
    Klingenberg, Tim
    Riener, Andreas
    Huber, Werner
    2019 IEEE INTERNATIONAL CONFERENCE OF VEHICULAR ELECTRONICS AND SAFETY (ICVES 19), 2019,
  • [8] Modeling photoplethysmographic signals in camera-based perfusion measurements: optoelectronic skin phantom
    Paul, Michael
    Mota, Filipa
    Antink, Christoph Hoog
    Blazek, Vladimir
    Leonhardt, Steffen
    BIOMEDICAL OPTICS EXPRESS, 2019, 10 (09) : 4353 - 4368
  • [10] Camera-based optical palpation
    Rowan W. Sanderson
    Qi Fang
    Andrea Curatolo
    Wayne Adams
    Devina D. Lakhiani
    Hina M. Ismail
    Ken Y. Foo
    Benjamin F. Dessauvagie
    Bruce Latham
    Chris Yeomans
    Christobel M. Saunders
    Brendan F. Kennedy
    Scientific Reports, 10