Design and testing of an MRI-compatible cycle ergometer for non-invasive cardiac assessments during exercise

被引:32
|
作者
Gusso, Silmara [1 ]
Salvador, Carlo [2 ]
Hofman, Paul [1 ]
Cutfield, Wayne [1 ]
Baldi, James C. [3 ]
Taberner, Andrew [2 ,4 ]
Nielsen, Poul [2 ,4 ]
机构
[1] Univ Auckland, Liggins Inst, Auckland 1, New Zealand
[2] Univ Auckland, Dept Engn Sci, Auckland 1, New Zealand
[3] Univ Otago, Dept Med, Otago, New Zealand
[4] Univ Auckland, Auckland Bioengn Inst, Auckland 1, New Zealand
来源
关键词
Cycle ergometer; Left ventricular function; Magnetic resonance imaging; LEFT-VENTRICULAR MASS; STROKE VOLUME; PHYSICAL-EXERCISE; DYNAMIC EXERCISE; ECHOCARDIOGRAPHY; HYPERTENSION; PLATEAU; SCANNER; ADULTS; YOUNG;
D O I
10.1186/1475-925X-11-13
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Magnetic resonance imaging (MRI) is an important tool for cardiac research, and it is frequently used for resting cardiac assessments. However, research into non-pharmacological stress cardiac evaluation is limited. Methods: We aimed to design a portable and relatively inexpensive MRI cycle ergometer capable of continuously measuring pedalling workload while patients exercise to maintain target heart rates. Results: We constructed and tested an MRI-compatible cycle ergometer for a 1.5 T MRI scanner. Resting and sub-maximal exercise images (at 110 beats per minute) were successfully obtained in 8 healthy adults. Conclusions: The MRI-compatible cycle ergometer constructed by our research group enabled cardiac assessments at fixed heart rates, while continuously recording power output by directly measuring pedal force and crank rotation.
引用
下载
收藏
页数:14
相关论文
共 50 条
  • [1] Design and testing of an MRI-compatible cycle ergometer for non-invasive cardiac assessments during exercise
    Silmara Gusso
    Carlo Salvador
    Paul Hofman
    Wayne Cutfield
    James C Baldi
    Andrew Taberner
    Poul Nielsen
    BioMedical Engineering OnLine, 11
  • [2] MRI-compatible non-invasive continuous blood pressure measurement using fiber optics
    Harja, Juha
    Myllyla, Teemu S.
    Sorvoja, Hannu S. S.
    Myllyla, Risto A.
    Elseoud, Ahmed A.
    Nikkinen, Juha
    Kiviniemi, Vesa
    Tervonen, Osmo
    SARATOV FALL MEETING 2009: INTERNATIONAL SCHOOL FOR JUNIOR SCIENTISTS AND STUDENTS ON OPTICS, LASER PHYSICS, AND BIOPHOTONICS, 2010, 7547
  • [3] The Design, Implementation, and Testing of a Sensorized MRI-Compatible Cello
    Hollinger, Avrum D.
    Wanderley, Marcelo M.
    IEEE SENSORS JOURNAL, 2015, 15 (11) : 6125 - 6134
  • [4] Cardiac Biomarkers: Invasive to Non-invasive Assessments
    Arshad, Mohd. Khairuddin Md
    Fathil, Mohamad Faris Bin Mohamad
    Gopinath, Subash C. B.
    Ruslinda, A. Rahim
    Nor, Mohammad Nuzaihan Md
    Lam, Hong Yoong
    Hashim, Uda
    CURRENT MEDICINAL CHEMISTRY, 2016, 23 (37) : 4270 - 4284
  • [5] Non-invasive, MRI-compatible, fibreoptic device for functional near-IR reflectometry of human brain
    Sorvoja, H. S. S.
    Myllyla, T. S.
    Kirillin, M. Yu.
    Sergeeva, E. A.
    Myllyla, R. A.
    Elseoud, A. A.
    Nikkinen, J.
    Tervonen, O.
    Kiviniemi, V.
    QUANTUM ELECTRONICS, 2010, 40 (12) : 1067 - 1073
  • [6] Non-invasive ultrasonic cardiac output monitoring in exercise testing
    Knobloch, Karsten
    Hoeltke, Volker
    Jakob, Ernst
    Vogt, Peter M.
    Phillips, Rob
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 126 (03) : 445 - 447
  • [7] NON-INVASIVE TEST FOR CONTINUOUS MONITORING OF CARDIAC-FUNCTION DURING EXERCISE TESTING
    MACARTHUR, C
    RICHON, J
    HON, E
    JILEK, J
    EDMISTON, WA
    ALLEN, JW
    CLINICAL RESEARCH, 1980, 28 (01): : A10 - A10
  • [8] Design of an MRI-compatible robotic stereotactic device for minimally invasive interventions in the breast
    Larson, BT
    Erdman, AG
    Tsekos, NV
    Yacoub, E
    Tsekos, PV
    Koutlas, LG
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (04): : 458 - 465
  • [9] NON-INVASIVE NON-NUCLEAR EXERCISE TESTING
    SAVVIDES, M
    FROELICHER, V
    CARDIOLOGY, 1984, 71 (2-3) : 100 - 117
  • [10] Non-invasive cardiac output evaluation during progressive exercise test
    Richard, R
    Lonsdorfer-Wolf, E
    Charloux, A
    Oswald-Mammoser, M
    Mettauer, B
    Lampert, E
    Lonsdorfer, J
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 2000, 440 (06): : R268 - R268