Status of non-contact electrical measurements

被引:0
|
作者
Komin, VV [1 ]
Bello, AF [1 ]
Brundle, CR [1 ]
Uritsky, YS [1 ]
机构
[1] Appl Mat Inc, Defect & Thin Films Characterizat Lab, Santa Clara, CA 95054 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Non-contact electrical metrology includes a variety of characterization techniques used to determine a number of material/device electrical parameters. These powerful methods, used on full wafers at various processing stages, complement the traditional device-based contact electrical (capacitance-voltage and current-voltage) measurements of MOS-based structures. The non-contact electrical techniques are usually built around measurements of surface photovoltage and surface voltage in combination with illumination and corona charge deposited on a sample. In principle this allows recombination lifetime, minority carrier diffusion length, and iron contamination density to be determined for bulk silicon; generation lifetime, doping density and doping profile to be measured for near-surface silicon; and equivalent oxide thickness, oxide charge density, mobile charge density, total charge density, flat band voltage, dielectric integrity and other parameters to be obtained for dielectric films. Interface trap density can be used for qualification of the interface between silicon and dielectric. The non-contact nature of these measurement techniques is particularly attractive because it makes most of them non-destructive, non-invasive and allows for diagnostics in the wafer processing stages, rather than waiting for final device characterization. Some methods offer high-resolution full-wafer mapping capabilities. A few of them are destructive by design such as the soft-breakdown field measurements. Most of the non-contact electrical measurements offer excellent process step isolation, and opportunity for integrated metrology. They are less expensive, do not require fabrication of the test structures, and require significantly less preparation and measurement time compared to the traditional MOS-device based analogues. This early and short loop measurement capability is the most important feature. In some circumstances the fast turn-around of the product characterization has so high priority that it makes a lower accuracy and/or frequent calibrations, necessary for some non-contact electrical techniques, tolerable (however, if there is no final correlation to device performance they are useless!). In this paper we review the non-contact electrical measurement techniques most often used in the semiconductor industry for characterization of bulk silicon, near-surface silicon, dielectrics and interface between silicon and dielectric films. We provide a comparison of the experimental data with the theory derived from widely accepted publications [1 - 5], and discuss the potential sources of discrepancies between the theory of some non-contact measurements and their implementation in commercial products. These potential discrepancies could cause systematic inaccuracy in measurements and disagreement between metrology using equipment fabricated by different vendors, resulting in considerable standardization challenges for the semiconductor industry. We highlight concerns when applying ASTM standards developed for non-contact electrical measurements [6 - 8] to current characterization of new semiconductor and dielectric materials. The goal of this paper is to demonstrate advantages and also the challenges in the non-contact electrical measurements, to define the problem areas and to provide recommendations for possible improvements and directions to overcome existing problems.
引用
收藏
页码:782 / 795
页数:14
相关论文
共 50 条
  • [11] Non-contact electrical characterization of SOI surfaces
    Lukasiak, L
    Roman, P
    Brubaker, M
    Anc, M
    Ruzyllo, J
    PROCEEDINGS OF THE NINTH INTERNATIONAL SYMPOSIUM ON SILICON-ON-INSULATOR TECHNOLOGY AND DEVICES, 1999, 99 (03): : 184 - 188
  • [12] CLINICAL TONOMETRIC MEASUREMENTS WITH NON-CONTACT TONOMETER
    AUGSBURG.A
    POLASKY, M
    WALBY, M
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1973, 50 (09): : 743 - 743
  • [13] Preamplifiers for non-contact capacitive biopotential measurements
    Peng, GuoChen
    Ignjatovic, Zeljko
    Bocko, Mark F.
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 1482 - 1485
  • [14] Continuous non-contact river discharge measurements
    Cheng, RT
    Costa, JE
    Mason, RR
    Plant, WJ
    Gartner, JW
    Spicer, K
    Haeni, FP
    Melcher, N
    PROCEEDINGS OF THE NINTH INTERNATIONAL SYMPOSIUM ON RIVER SEDIMENTATION, VOLS 1-4, 2004, : 2535 - 2542
  • [15] NON-CONTACT THERMOGRAPHY IN EQUIPMENT STATUS DIAGNOSTICS
    Kostelecky, Milan
    Prochazka, Miloslav
    NDE FOR SAFETY: DEFEKTOSKOPIE 2010, 2010, : 141 - 148
  • [16] A Non-Contact Hemodynamic Status and Location System
    McGrath, Braden
    De Marr, Catherine F.
    McGrath, Elizabeth
    McCaughan, Ann
    2009 FIRST ANNUAL ORNL BIOMEDICAL SCIENCE & ENGINEERING CONFERENCE: EXPLORING THE INTERSECTIONS OF INTERDISCIPLINARY BIOMEDICAL RESEARCH, 2009, : 57 - 60
  • [17] Non-contact ultrasonic measurements in food materials
    Saggin, R
    Coupland, JN
    FOOD RESEARCH INTERNATIONAL, 2001, 34 (10) : 865 - 870
  • [18] CLINICAL TONOMETRIC MEASUREMENTS WITH NON-CONTACT TONOMETER
    AUGSBURGER, A
    POLASKY, M
    WALBY, M
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1974, 51 (04): : 282 - 285
  • [19] Optical methods for non-contact measurements of membranes
    Roose, S.
    Stockman, Y.
    Rochus, P.
    Kuhn, T.
    Lang, M.
    Baier, H.
    Langlois, S.
    Casarosa, G.
    ACTA ASTRONAUTICA, 2009, 65 (9-10) : 1317 - 1329
  • [20] In situ non-contact measurements of surface roughness
    Quinsat, Yann
    Tournier, Christophe
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2012, 36 (01): : 97 - 103