Clinical application and improvement of a CNN-based autosegmentation model for clinical target volumes in cervical cancer radiotherapy

被引:15
|
作者
Chang, Yankui [1 ]
Wang, Zhi [1 ,2 ]
Peng, Zhao [1 ]
Zhou, Jieping [3 ]
Pi, Yifei [4 ]
Xu, X. George [1 ,3 ]
Pei, Xi [1 ,5 ]
机构
[1] Univ Sci & Technol China, Inst Nucl Med Phys, Hefei 230025, Anhui, Peoples R China
[2] Anhui Med Univ, Affiliated Hosp 1, Radiat Oncol Dept, Hefei, Peoples R China
[3] Univ Sci & Technol China, Affiliated Hosp 1, Radiat Oncol Dept, Hefei, Peoples R China
[4] Zhengzhou Univ, Affiliated Hosp 1, Radiat Oncol Dept, Zhengzhou, Peoples R China
[5] Anhui Wisdom Technol Co Ltd, Hefei, Anhui, Peoples R China
来源
关键词
adaptive improvement; autosegmentation; clinical target volumes; deep learning; AUTOMATIC SEGMENTATION; AUTO-SEGMENTATION; CT IMAGES; ORGANS; RISK; DELINEATION; VARIABILITY; ATLAS;
D O I
10.1002/acm2.13440
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective Clinical target volume (CTV) autosegmentation for cervical cancer is desirable for radiation therapy. Data heterogeneity and interobserver variability (IOV) limit the clinical adaptability of such methods. The adaptive method is proposed to improve the adaptability of CNN-based autosegmentation of CTV contours in cervical cancer. Methods This study included 400 cervical cancer treatment planning cases with CTV delineated by radiation oncologists from three hospitals. The datasets were divided into five subdatasets (80 cases each). The cases in datasets 1, 2, and 3 were delineated by physicians A, B, and C, respectively. The cases in datasets 4 and 5 were delineated by multiple physicians. Dataset 1 was divided into training (50 cases), validation (10 cases), and testing (20 cases) cohorts, and they were used to construct the pretrained model. Datasets 2-5 were regarded as host datasets to evaluate the accuracy of the pretrained model. In the adaptive process, the pretrained model was fine-tuned to measure improvements by gradually adding more training cases selected from the host datasets. The accuracy of the autosegmentation model on each host dataset was evaluated using the corresponding test cases. The Dice similarity coefficient (DSC) and 95% Hausdorff distance (HD_95) were used to evaluate the accuracy. Results Before and after adaptive improvements, the average DSC values on the host datasets were 0.818 versus 0.882, 0.763 versus 0.810, 0.727 versus 0.772, and 0.679 versus 0.789, which are improvements of 7.82%, 6.16%, 6.19%, and 16.05%, respectively. The average HD_95 values were 11.143 mm versus 6.853 mm, 22.402 mm versus 14.076 mm, 28.145 mm versus 16.437 mm, and 33.034 mm versus 16.441 mm, which are improvements of 37.94%, 37.17%, 41.60%, and 50.23%, respectively. Conclusion The proposed method improved the adaptability of the CNN-based autosegmentation model when applied to host datasets.
引用
收藏
页码:115 / 125
页数:11
相关论文
共 50 条
  • [21] Clinical Feasibility of Artificial Intelligence-Based Autosegmentation of the Left Anterior Descending Artery in Radiotherapy for Breast Cancer
    Mohan, Aditi
    Talapatra, Kaustav
    Sankhe, Manoj
    Kiron, G.
    Maniar, Priyal
    Kolekar, Akshat
    Kushe, Saakshi
    Kharote, Prashant
    Singh, Anuradha
    Patel, Keval
    Gupta, Aayush
    Patel, Devarsh
    Bardeskar, Nikhil
    Patkar, Deepak
    INDIAN JOURNAL OF MEDICAL AND PAEDIATRIC ONCOLOGY, 2024,
  • [22] Clinical application of intensity-modulated radiotherapy for locally advanced cervical cancer
    Kavanagh, BD
    Schefter, TE
    Wu, QW
    Tong, SD
    Newman, F
    Arnfield, M
    Benedict, SH
    McCourt, S
    Mohan, R
    SEMINARS IN RADIATION ONCOLOGY, 2002, 12 (03) : 260 - 271
  • [23] A prior-information-based automatic segmentation method for the clinical target volume in adaptive radiotherapy of cervical cancer
    Wang, Xuanhe
    Chang, Yankui
    Pei, Xi
    Xu, Xie George
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (05):
  • [24] Evaluation of peritumoral edema in the delineation of radiotherapy clinical target volumes for glioblastoma
    Chang, Eric L.
    Akyurek, Serap
    Avalos, Tedde
    Rebueno, Neal
    Spicer, Chris
    Garcia, John
    Famiglietti, Robin
    Allen, Pamela K.
    Chao, K. S. Clifford
    Mahajan, Anita
    Woo, Shiao Y.
    Maor, Moshe H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (01): : 144 - 150
  • [25] CNN-based Method for Classifying Cervical Cancer Cells in Pap Smear Images
    Austin, Remita
    Parvathi, R.
    Persis, P. Phebe
    CURRENT MEDICAL IMAGING, 2024, 20
  • [26] Clinical Assessment of Deep Learning-Based Autosegmentation On Nasopharyngeal Cancer
    Wang, J.
    Sun, S.
    Hu, W.
    Zhang, Z.
    MEDICAL PHYSICS, 2019, 46 (06) : E448 - E448
  • [27] GTV Based Automatic Delineation of Clinical Target Volume for Cervical Cancer
    Mao, X.
    Mao, S.
    Lu, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E694 - E694
  • [28] Assessment of accuracy and efficiency of atlas-based autosegmentation for prostate radiotherapy in a variety of clinical conditions
    Simmat, I.
    Georg, P.
    Georg, D.
    Birkfellner, W.
    Goldner, G.
    Stock, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 (09) : 807 - 813
  • [29] Delineation of clinical target volume and organs at risk in cervical cancer radiotherapy by deep learning networks
    Tian, Miao
    Wang, Hongqiu
    Liu, Xingang
    Ye, Yuyun
    Ouyang, Ganlu
    Shen, Yali
    Li, Zhiping
    Wang, Xin
    Wu, Shaozhi
    MEDICAL PHYSICS, 2023, 50 (10) : 6354 - 6365
  • [30] A CNN-based dose prediction method for brachytherapy treatment planning of patients with cervical cancer
    Yu, Lang
    Zhang, Wenjun
    Zhang, Jie
    Chen, Qi
    Bai, Lu
    Liu, Nan
    Pang, Tingtian
    Yang, Bo
    Qiu, Jie
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2024, 17 (03)