The reproducibility of tolerance to lower-body negative pressure and its quantification

被引:28
|
作者
Howden, R
Tranfield, PA
Lightfoot, JT
Brown, SJ
Swaine, IL
机构
[1] De Montfort Univ, Bedford MK40 2BZ, England
[2] Univ N Carolina, Dept Hlth Promot & Kinesiol, Charlotte, NC 28223 USA
关键词
LBNP tolerance index; cumulative stress index; blood pressure; heart rate;
D O I
10.1007/s004210100398
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The reproducibility of tolerance to lower-body negative pressure (LBNP) has not been assessed sufficiently. Furthermore, there has been confusion concerning the most appropriate index by which LBNP tolerance can be quantified. The purpose of this study was to assess the degree of reproducibility in presyncopal-symptom-limited LBNP (LBNPtol), using an LBNP chamber. Twenty physically active subjects [median age (range) 21 (18-27) years] underwent three successive LBNPtol tests with 72-120 h between each test. LBNPtol was quantified using the LBNP tolerance index (LTI; Delta mmHg(.)min), cumulative stress index (CSI; mmHg(.)min), duration of negative pressure (DNP) and maximum magnitude of negative pressure (MNP). Heart rate (f(c)), systolic (SBP) and diastolic (DBP) blood pressures from the three repeated tests were compared during a control period. The changes from control to maximum response (f(c), SBP, DBP) during LBNP were also compared, and percentage changes in estimated blood volume were measured. There were no statistical differences between any of these comparisons (P > 0.05). LTI and CSI were greater in the third test when compared to the first two tests (P < 0.05). The values for DNP and MNP were not statistically different between tests (P > 0.05). Measures of LTI and CSI showed an acceptable level of reproducibility for the first two repeated tests. However, there was an increase in LBNPtol on the third successive exposure to LBNP. These findings have shown that it is possible to achieve reproducible measures of tolerance to LBNP when using a custom-built chamber. This only applies to a test-retest procedure. Furthermore, these data also suggest that DNP and MNP do not adequately reflect the differences shown in LBNP tolerance when using LTI and CSI as measures.
引用
收藏
页码:462 / 468
页数:7
相关论文
共 50 条
  • [41] DISSOCIATION OF REGIONAL VASCULAR-RESPONSES TO PROLONGED LOWER-BODY NEGATIVE-PRESSURE
    HIRSCH, AT
    LEVENSON, DJ
    DZAU, VJ
    CUTLER, SS
    DOHERTY, AR
    CREAGER, MA
    CIRCULATION, 1986, 74 (04) : 430 - 430
  • [42] EFFECTS OF DYNAMIC EXERCISE ON CARDIOVASCULAR REGULATION DURING LOWER-BODY NEGATIVE-PRESSURE
    NISHIYASU, T
    SHI, XG
    GILLEN, CM
    MACK, GW
    NADEL, ER
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 1993, 64 (06): : 517 - 521
  • [43] Respiratory Pump Contributions to Hemodynamic Responses in Lower-Body Negative Pressure: Preliminary Results
    Fadil, Rabie
    Blaber, Andrew P.
    Tavakolian, Kouhyar
    2021 COMPUTING IN CARDIOLOGY (CINC), 2021,
  • [44] SPLANCHNIC AND FOREARM VASAMOTOR RESPONSES TO NECK SUCTION AND LOWER-BODY NEGATIVE-PRESSURE
    ESCOURROU, P
    RAFFESTIN, B
    PAPELIER, Y
    PUSSARD, E
    ROWELL, LB
    FASEB JOURNAL, 1991, 5 (05): : A1414 - A1414
  • [45] A DEVICE FOR COMBINED PASSIVE UPRIGHT TILTING AND LOWER-BODY NEGATIVE-PRESSURE IN MAN
    ELBEDAWI, KM
    HAINSWORTH, R
    JOURNAL OF PHYSIOLOGY-LONDON, 1993, 467 : P141 - P141
  • [46] EFFECT OF A CENTRAL REDISTRIBUTION OF FLUID VOLUME ON RESPONSE TO LOWER-BODY NEGATIVE-PRESSURE
    TOMASELLI, CM
    FREY, MAB
    KENNEY, RA
    HOFFLER, GW
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 1990, 61 (01): : 38 - 42
  • [47] COMPARISON OF MUSCLE SYMPATHETIC RESPONSES TO HEMORRHAGE AND LOWER-BODY NEGATIVE-PRESSURE IN HUMANS
    REA, RF
    HAMDAN, M
    CLARY, MP
    RANDELS, MJ
    DAYTON, PJ
    STRAUSS, RG
    JOURNAL OF APPLIED PHYSIOLOGY, 1991, 70 (03) : 1401 - 1405
  • [48] EXERCISE AGAINST LOWER-BODY NEGATIVE-PRESSURE AS A COUNTERMEASURE FOR CARDIOVASCULAR AND MUSCULOSKELETAL DECONDITIONING
    MURTHY, G
    WATENPAUGH, DE
    BALLARD, RE
    HARGENS, AR
    ACTA ASTRONAUTICA, 1994, 33 : 89 - 96
  • [49] VASOCONSTRICTOR RESPONSE TO LOWER-BODY NEGATIVE-PRESSURE IS ATTENUATED AFTER CARDIAC TRANSPLANTATION
    MORGAN, BJ
    RAHKO, PS
    PEASE, MO
    BERKOFF, HA
    DEBOER, LWV
    HANSON, P
    CIRCULATION, 1987, 76 (04) : 59 - 59
  • [50] Acute Fasting Decreases Tolerance to Lower Body Negative Pressure
    Gonzalez, Joshua E.
    Cooke, William H.
    FASEB JOURNAL, 2022, 36