The influence of acetabular component position on wear in total hip arthroplasty

被引:163
|
作者
Wan, Zhinian [1 ]
Boutary, Myriam [1 ]
Dorr, Lawrence D. [1 ]
机构
[1] Arthritis Inst, Inglewood, CA USA
来源
JOURNAL OF ARTHROPLASTY | 2008年 / 23卷 / 01期
关键词
cup position; THA; acetabulum; wear; center of rotation;
D O I
10.1016/j.arth.2007.06.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Our experience has implicated cup inclination as an important factor in wear, whereas others have suggested that the hip center of rotation (COR) must be closely reestablished to reduce wear. We conducted a retrospective study to determine the relative importance of these 2 factors. One hundred thirty-nine total hip arthroplasties were studied after a mean follow-up of 9.2 years (range, 6-3 years). Forty-nine of 139 operated hips had a contralateral normal hip, which allowed the most accurate measurement of the influence of change in the COR. Wear was related to the inclination of the cup but not to a change in the COR. Secondarily, wear was less with a ceramic-polyethylene polyarticular surface than with metal-polyethylene. The importance of this data is related to cup implantation techniques. The hip COR can be moved superiorly and/or medially to permit cup inclination below 45 degrees with correct cup coverage.
引用
收藏
页码:51 / 56
页数:6
相关论文
共 50 条
  • [21] Catastrophic failure and metallosis of the acetabular component in total hip arthroplasty
    Ozan, Firat
    Kahraman, Murat
    Baktir, Ali
    Gencer, Kursat
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [22] Are Acetabular Component Alignment Guides for Total Hip Arthroplasty Accurate?
    Minoda, Yukihide
    Ohzono, Kenji
    Aihara, Masaharu
    Umeda, Naoya
    Tomita, Masuhiro
    Hayakawa, Keiko
    [J]. JOURNAL OF ARTHROPLASTY, 2010, 25 (06): : 986 - 989
  • [23] Catastrophic failure and metallosis of the acetabular component in total hip arthroplasty
    Fırat Ozan
    Murat Kahraman
    Ali Baktır
    Kürşat Gençer
    [J]. Journal of Orthopaedic Surgery and Research, 16
  • [24] Total hip arthroplasty with the use of nonmodular cementless acetabular component
    Kim, SY
    Kim, DH
    Oh, CW
    Kim, PT
    Ihn, JC
    Kim, SY
    [J]. JOURNAL OF ARTHROPLASTY, 2005, 20 (05): : 632 - 638
  • [25] Functional acetabular component position with supine total hip replacement
    Eilander, W.
    Harris, S. J.
    Henkus, H. E.
    Cobb, J. P.
    Hogervorst, T.
    [J]. BONE & JOINT JOURNAL, 2013, 95B (10): : 1326 - 1331
  • [26] Intraoperative measurement of acetabular component position using imageless navigation during revision total hip arthroplasty
    Mei, Xin Yu
    Etemad-Rezaie, Ali
    Safir, Oleg A.
    Gross, Allan E.
    Kuzyk, Paul R.
    [J]. CANADIAN JOURNAL OF SURGERY, 2021, 64 (04) : E442 - E448
  • [27] What is the Fate of Total Hip Arthroplasty (THA) Acetabular Component Orientation When Evaluated in the Standing Position?
    Tiberi, John V., III
    Antoci, Valentin
    Malchau, Henrik
    Rubash, Harry E.
    Freiberg, Andrew A.
    Kwon, Young-Min
    [J]. JOURNAL OF ARTHROPLASTY, 2015, 30 (09): : 1555 - 1560
  • [28] Effects of acetabular abduction on cup wear rates in total hip arthroplasty
    Del Schutte, H
    Lipman, AJ
    Bannar, SM
    Livermore, JT
    Ilstrup, D
    Morrey, BF
    [J]. JOURNAL OF ARTHROPLASTY, 1998, 13 (06): : 621 - 626
  • [29] Effect of acetabular modularity on polyethylene wear and osteolysis in total hip arthroplasty
    Young, AM
    Sychterz, CJ
    Hopper, RH
    Engh, CA
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (01): : 58 - 63
  • [30] The effect of joint loading on acetabular wear measurement in total hip arthroplasty
    Martell, JM
    Leopold, SS
    Liu, XL
    [J]. JOURNAL OF ARTHROPLASTY, 2000, 15 (04): : 512 - 518