Using Eye Aspect Ratio to Enhance Fast and Objective Assessment of Facial Paralysis

被引:7
|
作者
Feng, Jialing [1 ]
Guo, Zhexiao [1 ,2 ]
Wang, Jun [3 ]
Dan, Guo [1 ,2 ]
机构
[1] Shenzhen Univ, Sch Biomed Engn, Hlth Sci Ctr, Shenzhen, Peoples R China
[2] Shenzhen Inst Neurosci, Shenzhen, Peoples R China
[3] Southern Med Univ, Shenzhen Hosp, Shenzhen, Peoples R China
关键词
GRADING SYSTEM;
D O I
10.1155/2020/1038906
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
A rapid and objective assessment of the severity of facial paralysis allows rehabilitation physicians to choose the optimal rehabilitation treatment regimen for their patients. In this study, patients with facial paralysis were enrolled as study objects, and the eye aspect ratio (EAR) index was proposed for the eye region. The correlation between EAR and the facial nerve grading system 2.0 (FNGS 2.0) score was analyzed to verify the ability of EAR to enhance FNGS 2.0 for the rapid and objective assessment of the severity of the facial paralysis. Firstly, in order to accurately calculate the EAR, we constructed a landmark detection model based on the face images of facial paralysis patients (FP-FLDM). Evaluation results showed that the error rate of facial feature point detection in patients with facial paralysis of FP-FLDM is 17.1%, which was significantly superior to the landmark detection model based on normal face images (NF-FLDM). Secondly, in this study, the Frechet distance was used to calculate the difference in bilateral EAR of facial paralysis patients and to verify the correlation between this difference and the corresponding FNGS 2.0 score. The results showed that the higher the FNGS 2.0 score , the greater the difference in bilateral EAR. The correlation coefficient between the bilateral EAR difference and the corresponding FNGS 2.0 score was 0.9673, indicating a high correlation. Finally, through a 10-fold crossvalidation, we can know that the accuracy of scoring the eyes of patients with facial paralysis using EAR was 85.7%, which can be used to enhance the objective and rapid assessment of the severity of facial paralysis by FNGS 2.0.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Effective learning assessment using eye tracking and facial recognition
    Yang, Changyong
    Zhou, Jing
    Zheng, Kun
    He, Wei
    Yan, Feng
    Yin, Weizhen
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 125 : 3 - 4
  • [22] Objective Assessment of Eye Dominance Using the VEP: A Pilot Study
    Willeford, Kevin T.
    Ciuffreda, Kenneth J.
    Zikos, George
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2016, 42 (02): : 129 - 134
  • [23] Reliability Between In-Person and Still Photograph Assessment of Facial Function in Facial Paralysis Using the eFACE Facial Grading System
    Malka, Ronit
    Miller, Matthew
    Guarin, Diego
    Fullerton, Zoe
    Hadlock, Tessa
    Banks, Caroline
    FACIAL PLASTIC SURGERY & AESTHETIC MEDICINE, 2021, 23 (05) : 344 - 349
  • [24] Production issues for high aspect ratio Lobster-eye optics using LIGA
    A. G. Peele
    T. H. K. Irving
    K. A. Nugent
    D. C. Mancini
    N. Moldovan
    T. R. Christenson
    Microsystem Technologies, 2002, 9 : 55 - 60
  • [25] Production issues for high aspect ratio Lobster-eye optics using LIGA
    Peele, AG
    Irving, THK
    Nugent, KA
    Mancini, DC
    Moldovan, N
    Christenson, TR
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2002, 9 (1-2): : 55 - 60
  • [26] Production issues for high aspect ratio Lobster-eye optics using LIGA
    Peele, A. G.
    Vora, K. D.
    Shew, B. -Y.
    Loechl, B.
    Harvey, E. C.
    Hayes, J. P.
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2007, 13 (5-6): : 511 - 515
  • [27] Production issues for high aspect ratio Lobster-eye optics using LIGA
    A. G. Peele
    K. D. Vora
    B.-Y. Shew
    B. Loechl
    E. C. Harvey
    J. P. Hayes
    Microsystem Technologies, 2007, 13 : 511 - 515
  • [28] Real-time classification for autonomous drowsiness detection using eye aspect ratio
    Souto Maior, Caio Bezerra
    das Chagas Moura, Marcio Jose
    Marques Santana, Joao Mateus
    Lins, Isis Didier
    EXPERT SYSTEMS WITH APPLICATIONS, 2020, 158
  • [29] Real-time classification for autonomous drowsiness detection using eye aspect ratio
    Maior, Caio Bezerra Souto
    Moura, Márcio José das Chagas
    Santana, João Mateus Marques
    Lins, Isis Didier
    Expert Systems with Applications, 2021, 158
  • [30] Tracking Early Differences in Tetris Performance Using Eye Aspect Ratio Extracted Blinks
    Guglielmo, Gianluca
    Klincewicz, Michal
    Veld, Elisabeth Huis in't
    Spronck, Pieter
    IEEE TRANSACTIONS ON GAMES, 2024, 16 (03) : 735 - 741