CT radiation dose and image quality

被引:39
|
作者
Payne, JT [1 ]
机构
[1] Abbott NW Hosp, Minneapolis, MN 55407 USA
关键词
D O I
10.1016/j.rcl.2005.07.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
CT scanning burst on the diagnostic imaging scene in 1973, sprinted for almost a decade, and then settled into comfortable midlife. But the quiet life did not last long. Technologic advances thrust CT scanning back to center stage. High-frequency generators with ever-higher power ratings and specially designed CT x-ray tubes with ever-higher heat storage permitted the advent of faster subsecond scans. These advances along with the development of slip ring electrical energy transfer allowed for continuous gantry rotation and the birth of spiral or helical scanning [1]. If that were not enough, multirow detector arrays were developed to increase the area of coverage during one gantry rotation. This facilitates volume CT scanning of whole organs in a single breath-hold. Improvements in software have led to real-time 3-D displays of volume-rendered data, as used in virtual CT colonoscopy, CT angiography, CT coronary calcium scoring, and other useful applications [2]. These technologic advances have expanded the role of CT in diagnostic imaging greatly. The annual number of CT studies in the United States more than tripled from 3.6 million in 1980 to 13.3 million in 1990 and then more than doubled to 33 million in 1998 [3]. By 2001, CT scanning comprised more than 13% of all radiology procedures. Unfortunately, the collective radiation dose from CT procedures increased even faster than the increase in the number of studies. The National Radiological Protection Board in the United Kingdom indicated that in 1989, CT studies comprised only 2% of all imaging studies but contributed to 20% of the total patient dose. Subsequent study analysis showed that CT contribution to overall patient dose has risen to 40% [4]. In a 2000 report of the United Nations Scientific Committee on the Effects of Atomic Radiation, the frequency of CT examinations for all imaging procedures was approximately 5%, but the CT radiation dose was approximately 34% of the total imaging dose and was the largest single sector of radiation dose [5]. In the United States, CT contribution to overall patient dose in some departments may be as high as 67% [4]. The rising total patient radiation dose from CT primarily is the result of its increased use and increased number of images per examination. In the early days, a CT study consisted of 20 similar to 50 images. Today, it is not unusual to have CT studies with 200 - 1000 images or more. Initially, CT was used almost exclusively to rule out malignant disease or replace procedures of even graver danger (Does anyone remember the air contrast pneumo-encephalogram?) and radiation dose was not an issue in most of these cases. Today, with the capability of performing rapid multiphase contrast enhanced studies, screening studies, and increased use, the collective CT radiation patient dose is adding up. What is lacking is good radiation dose management in CT imaging [6]. Since their inception, CT studies have been performed with standard one-size-fits-all technique protocols [7]. A series of journal articles in 2001 concerning the risk of radiation-induced fatal cancer in pediatric patients, and the fact that pediatric patients were being imaged with adult CT protocols, caught media attention and caused considerable public and professional outcry [8 - 11]. This had the positive effect of focusing attention on better CT radiation dose use and implementation of as-low-as-reasonably-achievable (ALARA) concepts into CT technique protocols. Appropriateness criteria now are recommended in the selection of CT imaging examinations. The ALARA concept i evoked for CT radiation dose management. Questions are being asked: What is an appropriate amount of radiation for CT procedures? How can the radiation needed for CT scanning be optimized? Answering these questions requires a basic understanding of CT radiation dose and the factors that determine the amount of radiation used in CT scanning.
引用
收藏
页码:953 / +
页数:11
相关论文
共 50 条
  • [41] Tradeoffs in image quality and radiation dose
    McNitt-Gray, M
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1802 - 1802
  • [42] Clinical Low Dose Photon Counting CT for the Detection of Urolithiasis: Evaluation of Image Quality and Radiation Dose
    Niehoff, Julius Henning
    Carmichael, Alexandra Fiona
    Woeltjen, Matthias Michael
    Boriesosdick, Jan
    Schmidt, Ingo Lopez
    Michael, Arwed Elias
    Hokamp, Nils Grosse
    Piechota, Hansjuergen
    Borggrefe, Jan
    Kroeger, Jan Robert
    [J]. TOMOGRAPHY, 2022, 8 (04) : 1666 - 1675
  • [43] Low-dose CT angiography of the lower extremities: a comparison study of image quality and radiation dose
    Park, S.
    Park, S. H.
    Hwang, J. H.
    Kim, J. H.
    Lee, K. H.
    Shin, J. H.
    Pak, S. Y.
    Kang, J. M.
    [J]. CLINICAL RADIOLOGY, 2021, 76 (02) : 156.e19 - 156.e26
  • [44] Low-dose, volumetric helical CT - Image quality, radiation dose, and usefulness for evaluation of bronchiectasis
    Jung, KJ
    Lee, KS
    Kim, SY
    Kim, TS
    Pyeun, YS
    Lee, JY
    [J]. INVESTIGATIVE RADIOLOGY, 2000, 35 (09) : 557 - 563
  • [45] A technique for multi-dimensional optimization of radiation dose, contrast dose, and image quality in CT imaging
    Sahbaee, Pooyan
    Abadi, Ehsan
    Sanders, Jeremiah
    Becchetti, Marc
    Zhang, Yakun
    Agasthya, Greeshma
    Segars, Paul
    Samei, Ehsan
    [J]. MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [46] Low dose volumetric helical CT: Image quality, radiation dose and usefulness in the evaluation of airway diseases
    Jung, KJ
    Lee, KS
    Kim, S
    Kim, T
    Pyeun, Y
    Lee, JY
    [J]. RADIOLOGY, 1999, 213P : 260 - 260
  • [47] Image texture and radiation dose properties in CT
    Mozejko, Dawid
    Andersen, Hilde Kjernlie
    Pedersen, Marius
    Waaler, Dag
    Martinsen, Anne Catrine Traegde
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03): : 408 - 418
  • [48] RADIONUCLIDE BONE SPECT-CT: LOWERING DOSE OF CT SIGNIFICANTLY REDUCES RADIATION DOSE WITHOUT IMPACTING THE IMAGE QUALITY
    Gupta, S. K.
    Trethewey, S.
    Brooker, B.
    Rutherford, N.
    Viswanathan, S.
    [J]. INTERNAL MEDICINE JOURNAL, 2015, 45 : 41 - 41
  • [49] Enhancing Image Quality in the Era of Radiation Dose Reduction: Postprocessing Techniques for Body CT
    Johnson, Pamela T.
    Fishman, Elliot K.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2018, 15 (03) : 486 - 488
  • [50] Effect of bismuth breast shielding on radiation dose and image quality in coronary CT angiography
    Andrew J. Einstein
    Carl D. Elliston
    Daniel W. Groves
    Bin Cheng
    Steven D. Wolff
    Gregory D. N. Pearson
    M. Robert Peters
    Lynne L. Johnson
    Sabahat Bokhari
    Gary W. Johnson
    Ketan Bhatia
    Theodore Pozniakoff
    David J. Brenner
    [J]. Journal of Nuclear Cardiology, 2012, 19 : 100 - 108