Group-wise similarity registration of point sets using Student's t-mixture model for statistical shape models

被引:34
|
作者
Ravikumar, Nishant [1 ,2 ]
Gooya, Ali [1 ,3 ]
Cimen, Serkan [1 ,3 ]
Frangi, Alejandro F. [1 ,3 ]
Taylor, Zeike A. [1 ,2 ]
机构
[1] INSIGNEO Inst Sil Med, CISTIB Ctr Computat Imaging & Simulat Technol Bio, Sheffield, S Yorkshire, England
[2] Univ Sheffield, Dept Mech Engn, Sheffield, S Yorkshire, England
[3] Univ Sheffield, Dept Elect & Elect Engn, Sheffield, S Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
Group-wise point set registration; Statistical shape models; Student's t-mixture model; Expectation-maximisation (EM); GENERATION;
D O I
10.1016/j.media.2017.11.012
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A probabilistic group-wise similarity registration technique based on Student's t-mixture model (TMM) and a multi-resolution extension of the same (mr-TMM) are proposed in this study, to robustly align shapes and establish valid correspondences, for the purpose of training statistical shape models (SSMs). Shape analysis across large cohorts requires automatic generation of the requisite training sets. Automated segmentation and landmarking of medical images often result in shapes with varying proportions of outliers and consequently require a robust method of alignment and correspondence estimation. Both TMM and mrTMM are validated by comparison with state-of-the-art registration algorithms based on Gaussian mixture models (GMMs), using both synthetic and clinical data. Four clinical data sets are used for validation: (a) 2D femoral heads (K = 1000 samples generated from DXA images of healthy subjects); (b) control-hippocampi (K = 50 samples generated from Tl-weighted magnetic resonance (MR) images of healthy subjects); (c) MCI-hippocampi (K = 28 samples generated from MR images of patients diagnosed with mild cognitive impairment); and (d) heart shapes comprising left and right ventricular endocardium and epicardium (K = 30 samples generated from short-axis MR images of: 10 healthy subjects, 10 patients diagnosed with pulmonary hypertension and 10 diagnosed with hypertrophic cardiomyopathy). The proposed methods significantly outperformed the state-of-the-art in terms of registration accuracy in the experiments involving synthetic data, with mrTMM offering significant improvement over TMM. With the clinical data, both methods performed comparably to the state-of-the-art for the hippocampi and heart data sets, which contained few outliers. They outperformed the state-of-the-art for the femur data set, containing large proportions of outliers, in terms of alignment accuracy, and the quality of SSMs trained, quantified in terms of generalization, compactness and specificity. (C) 2017 The Authors. Published by Elsevier B.V.
引用
收藏
页码:156 / 176
页数:21
相关论文
共 50 条
  • [21] SAR Image Segmentation with Structure Tensor Based Hierarchical Student's t-Mixture Model
    Ge, Huilin
    Sung, Yahui
    Huang, Yueh-Min
    Lim, Se-Jung
    JOURNAL OF INTERNET TECHNOLOGY, 2020, 21 (03): : 615 - 628
  • [22] Group-Wise Point-Set Registration Using a Novel CDF-Based Havrda-Charvat Divergence
    Chen, Ting
    Vemuri, Baba C.
    Rangarajan, Anand
    Eisenschenk, Stephan J.
    INTERNATIONAL JOURNAL OF COMPUTER VISION, 2010, 86 (01) : 111 - 124
  • [23] Content-based image retrieval using student’s t-mixture model and constrained multiview nonnegative matrix factorization
    Hongqing Zhu
    Qunyi Xie
    Multimedia Tools and Applications, 2018, 77 : 14207 - 14239
  • [24] Rotation robust non-rigid point set registration with Bayesian student's t mixture model
    Yang, Lijuan
    Yang, Ying
    Wang, Changpeng
    Li, Fuxiao
    VISUAL COMPUTER, 2023, 39 (01): : 367 - 379
  • [25] Rotation robust non-rigid point set registration with Bayesian student’s t mixture model
    Lijuan Yang
    Ying Yang
    Changpeng Wang
    Fuxiao Li
    The Visual Computer, 2023, 39 : 367 - 379
  • [26] Content-based image retrieval using student's t-mixture model and constrained multiview nonnegative matrix factorization
    Zhu, Hongqing
    Xie, Qunyi
    MULTIMEDIA TOOLS AND APPLICATIONS, 2018, 77 (11) : 14207 - 14239
  • [27] Coronary Artery Stenosis Quantification for Computed Tomography Angiography Based on Modified Student's t-Mixture Model
    Sun, Qiaoyu
    Yang, Guanyu
    Shu, Huazhong
    Shi, Daming
    ETRI JOURNAL, 2017, 39 (05) : 662 - 671
  • [28] Correction: Rotation robust non-rigid point set registration with Bayesian student’s t mixture model
    Lijuan Yang
    Ying Yang
    Changpeng Wang
    Fuxiao Li
    The Visual Computer, 2024, 40 : 457 - 457
  • [29] Accurate and Robust Non-rigid Point Set Registration using Student’s-t Mixture Model with Prior Probability Modeling
    Zhiyong Zhou
    Jianfei Tu
    Chen Geng
    Jisu Hu
    Baotong Tong
    Jiansong Ji
    Yakang Dai
    Scientific Reports, 8
  • [30] Direct point-based registration for precise non-rigid surface matching using Student's-t mixture model
    Zhou, Zhiyong
    Tong, Baotong
    Geng, Chen
    Hu, Jisu
    Zheng, Jian
    Dai, Yakang
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2017, 33 : 10 - 18