Linescan microscopy data to extract diffusion coefficient of a fluorescent species using a commercial confocal microscope

被引:8
|
作者
Bathe-Peters, Marc [1 ,2 ]
Gmach, Philipp [1 ,2 ]
Annibale, Paolo [1 ]
Lohse, Martin J. [1 ,2 ]
机构
[1] Helmholtz Assoc, Max Delbruck Ctr Mol Med, Berlin, Germany
[2] Julius Maximilian Univ, Wurzburg, Germany
来源
DATA IN BRIEF | 2020年 / 29卷
关键词
Confocal microscopy; Fluorescence correlation spectroscopy; Membrane receptor; Diffusion;
D O I
10.1016/j.dib.2019.105063
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We report here on the measurement of the diffusion coefficient of fluorescent species using a commercial microscope possessing a resonant scanner. Sequential linescans with a rate of up to 12 kHz yield a temporal resolution of 83 ms, making the setup amenable to measure diffusion rates over a range covering at least three orders of magnitude, from 100 mu m(2)/s down to 0.1 mu m(2)/s. We share representative data sets covering (i) the diffusion of a dye molecule, observed in media of different viscosities and (ii) the diffusion of a prototypical membrane receptor. The data can be valuable for researchers interested in the rapid diffusion properties of nuclear, cytosolic or membrane bound proteins fused to fluorescent tags. (C) 2020 The Authors. Published by Elsevier Inc.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] A line scanning confocal fluorescent microscope using a CMOS rolling shutter as an adjustable aperture
    Mei, E.
    Fomitchov, P. A.
    Graves, R.
    Campion, M.
    JOURNAL OF MICROSCOPY, 2012, 247 (03) : 269 - 276
  • [22] Orbital single particle tracking on a commercial confocal microscope using piezoelectric stage feedback
    Lanzano, L.
    Gratton, E.
    METHODS AND APPLICATIONS IN FLUORESCENCE, 2014, 2 (02):
  • [23] Confocal microscopy studies of secretion using insulin-green fluorescent protein
    Patterson, GH
    Magnuson, MA
    Piston, DW
    BIOPHYSICAL JOURNAL, 1996, 70 (02) : WP277 - WP277
  • [24] Imaging of single fluorescent molecules using video-rate confocal microscopy
    Tadakuma, H
    Yamaguchi, J
    Ishihama, Y
    Funatsu, T
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2001, 287 (02) : 323 - 327
  • [25] AEROSOLIZED FLUORESCENT MICROSPHERES DETECTED IN THE LUNG USING CONFOCAL SCANNING LASER MICROSCOPY
    PINKERTON, KE
    GALLEN, JT
    MERCER, RR
    WONG, VC
    PLOPPER, CG
    TARKINGTON, BK
    MICROSCOPY RESEARCH AND TECHNIQUE, 1993, 26 (05) : 437 - 443
  • [26] Visualizing the Effects of Biofilm Structures on the Influx of Fluorescent Material Using Combined Confocal Reflection and Fluorescent Microscopy
    Yawata, Yutaka
    Uchiyama, Hiroo
    Nomura, Nobuhiko
    MICROBES AND ENVIRONMENTS, 2010, 25 (01) : 49 - 52
  • [27] Doubling the resolution of a confocal spinning-disk microscope using image scanning microscopy
    Shun Qin
    Sebastian Isbaner
    Ingo Gregor
    Jörg Enderlein
    Nature Protocols, 2021, 16 : 164 - 181
  • [28] Doubling the resolution of a confocal spinning-disk microscope using image scanning microscopy
    Qin, Shun
    Isbaner, Sebastian
    Gregor, Ingo
    Enderlein, Joerg
    NATURE PROTOCOLS, 2021, 16 (01) : 164 - 181
  • [29] Highly accurate characterization of engineering surfaces using a micromirror based confocal microscopy - Verification of a micromirror based confocal microscope
    Tiftikci, KA
    Jansen, M
    Morel, M
    Velzel, C
    Schellekens, PHJ
    MEASURE AND QUALITY CONTROL IN PRODUCTION, 2004, 1860 : 101 - 106
  • [30] Measurement of diffusion of fluorescent compounds and autofluorescence in skin in vivo using a confocal instrument
    Buttenschoen, K. K.
    Sutton, E. E.
    Daly, D.
    Girkin, J. M.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS XII, 2016, 9689