Data assessment of the ARFTG microwave vector network analyzer Measurement Comparison Program

被引:1
|
作者
Wong, K [1 ]
机构
[1] Hewlett Packard Co, Microwave Technol Div, Santa Rosa, CA USA
关键词
D O I
10.1109/ARFTG.1997.327268
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The purpose of the Automatic Radio Frequency Techniques Group (ARFTG) Measurement Comparison Program (MCP) is to allow participating laboratories to compare their measurements on the ARFTG standards kits to measurements obtained from other laboratories. The MCP is designed to permit the intercomparison of a large number of automatic vector network analyzers (VNA) and of different connector types. The MCP should give the participants more confidence in their measurement capability and assist them in identifying measurement deficiencies. Avast set of data has been collected from the Measurement Comparison Program. This paper presents a brief description of measurement requirements and then an assessment of the interlaboratory measurement data of each kit. Conclusions will be presented regarding the repeatability and reproducibility of each kit.
引用
收藏
页码:138 / 164
页数:27
相关论文
共 50 条
  • [21] On-die decoupling capacitor measurement using Vector Network Analyzer
    Guo, Fei
    Frankovich, Mark
    ELECTRICAL PERFORMANCE OF ELECTRONIC PACKAGING, 2006, : 25 - +
  • [22] Calibration-measurement unit for the automation of vector network analyzer measurements
    Rolfes, I
    Will, B.
    Schiek, B.
    ADVANCES IN RADIO SCIENCE, 2008, 6 : 27 - 30
  • [23] Design improvement of vector network analyzer for high dynamic range measurement
    Zhang Qinglong
    Wei Liancheng
    Liang Shengli
    PROCEEDINGS OF 2015 IEEE 12TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), VOL. 2, 2015, : 1019 - 1023
  • [24] Measurement of ultra wideband channel sounding using vector network analyzer
    School of Electrical, Computer and Telecommunications Engineering, University of Wollongong, Northfields Avenue, Wollongong, Australia
    不详
    Telkomnika Telecomun. Compt. Electr. Control, 3 (859-869):
  • [25] Reduction of Measurement Error of Optical Vector Network Analyzer Based on DPMZM
    Li, Wei
    Sun, Wen Hui
    Wang, Wen Ting
    Wang, Li Xian
    Liu, Jian Guo
    Zhu, Ning Hua
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2014, 26 (09) : 866 - 869
  • [26] The Atmospheric radiation measurement (ARM) program network of microwave radiometers: instrumentation, data, and retrievals
    Cadeddu, M. P.
    Liljegren, J. C.
    Turner, D. D.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2013, 6 (09) : 2359 - 2372
  • [27] Indirect Measurement of Switch Terms of a Vector Network Analyzer With Reciprocal Devices
    Hatab, Ziad
    Gadringer, Michael Ernst
    Boesch, Wolfgang
    IEEE MICROWAVE AND WIRELESS TECHNOLOGY LETTERS, 2023, 33 (11): : 1588 - 1591
  • [28] A Compact X-Band Vector Network Analyzer for Microwave Image Sensing
    Peng, Kang-Chun
    Lin, Chiu-Chin
    Li, Cyuan-Fong
    Hung, Cheng-Yuan
    Hsieh, Yu-Sung
    Chen, Chien-Chang
    IEEE SENSORS JOURNAL, 2019, 19 (09) : 3304 - 3313
  • [29] A multi-frequency polarimetric microwave scatterometer based on a Vector Network Analyzer
    D'Alessio, AC
    Posa, F
    Sabatelli, V
    Casarano, D
    SAR IMAGE ANALYSIS, MODELING, AND TECHNIQUES II, 1999, 3869 : 146 - 156
  • [30] COMPUTER CORRECTION OF A MICROWAVE NETWORK ANALYZER WITHOUT ACCURATE FREQUENCY MEASUREMENT
    GOULD, JW
    RHODES, GM
    ELECTRONICS LETTERS, 1973, 9 (21) : 494 - 495